Renewable amperometric immunosensor for Schistosoma japonium antibody assay

被引:106
作者
Liu, GD
Wu, ZY
Wang, SP
Shen, GL
Yu, RQ [1 ]
机构
[1] Hunan Univ, Coll Chem & Chem Engn, Inst Chemometr & Sensing Technol, Changsha 410082, Peoples R China
[2] Cent S Univ, Dept Parasitol, Changsha 410078, Peoples R China
关键词
D O I
10.1021/ac0101048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A renewable amperometric immunosensor has been proposed for the determination of Schistosoma japonium antibody (SjAb) in rabbit serum. A paraffin-graphite-Schistosoma japonium antigen (SjAb) biocomposite, which needs no additional curing, was directly used to construct the immunosensors. The analytical sample containing the desired SjAb was mixed with SjAb labeled with horseradish peroxidase (HRP) to form the incubation solution for the competitive binding assay. Amperometry was used to determine the amount of HRP fixed on the sensor surface, which was related to the content of desired SjAb, Assay conditions were optimized, including the selection of substrate, the loading of SjAg in the biocomposite, the amount of labeled SjAb in the incubation solution, the incubation time, and the temperature. Using o-aminophenol (o-AP) as a substrate, amperometric detection at -200 mV (vs SCE) resulted in a pseudolinear detection range of about 0.36 to 14 mug/mL, with a detection limit of 0.36 mug/mL. Rabbit serum samples with varying infection degrees were analyzed, and the results demonstrated that the concentration that is detectable in this system meets the demands of clinical analyses. A new surface on the immunosensor for use in another competitive assay can be obtained by removing the original one and polishing the surface.
引用
收藏
页码:3219 / 3226
页数:8
相关论文
共 27 条
  • [1] New variants of enzyme immunoassay of antibodies to DNA
    Babkina, SS
    Medyantseva, EP
    Budnikov, HC
    Tyshiek, MP
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (21) : 3827 - 3831
  • [2] Development of amperometric and microgravimetric immunosensors and reversible immunosensors using antigen and photoisomerizable antigen monolayer electrodes
    Blonder, R
    Levi, S
    Tao, GL
    BenDov, I
    Willner, I
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1997, 119 (43) : 10467 - 10478
  • [3] Bossuyt X, 1998, CLIN CHEM, V44, P760
  • [4] Universal buffer soluttons and the association constant of veronal
    Britton, HTS
    Robinson, RA
    [J]. JOURNAL OF THE CHEMICAL SOCIETY, 1931, : 1456 - 1462
  • [5] González-Martínez MA, 1999, ANAL CHIM ACTA, V386, P201, DOI 10.1016/S0003-2670(99)00032-X
  • [6] Hage DS, 1999, ANAL CHEM, V71, p294R
  • [7] Differential pulse voltammetric enzyme-linked immunoassay for the determination of Helicobacter pylori specific immunoglobulin G (IgG) antibody
    He, YN
    Chen, HY
    Zheng, JJ
    Zhang, GY
    Chen, ZL
    [J]. TALANTA, 1997, 44 (05) : 823 - 830
  • [8] STRATEGIES FOR ELECTROCHEMICAL IMMUNOASSAY
    HEINEMAN, WR
    HALSALL, HB
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (12) : 1321 - &
  • [9] Alkaline phosphatase as a label for immunoassay using amperometric detection with a variety of substrates and an optimal buffer system
    Kreuzer, MP
    O'Sullivan, CK
    Guilbault, GG
    [J]. ANALYTICA CHIMICA ACTA, 1999, 393 (1-3) : 95 - 102
  • [10] Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode
    Lee, KS
    Kim, TH
    Shin, MC
    Lee, WY
    Park, JK
    [J]. ANALYTICA CHIMICA ACTA, 1999, 380 (01) : 17 - 26