Development of evanescent wave all-fiber immunosensor for environmental water analysis

被引:81
作者
Long, F. [1 ]
He, M. [1 ]
Shi, H. C. [1 ]
Zhu, A. N. [1 ]
机构
[1] Tsinghua Univ, Dept Environm Sci & Engn, Environm Simulate & Pollut Control State Key Join, Beijing 100084, Peoples R China
关键词
immunosensor; evanescent wave; fluorescence; immunoassay;
D O I
10.1016/j.bios.2007.09.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A compact and portable evanescent wave all-fiber immunosensor is developed, which employs a novel single-multi-mode fiber optic coupler for exciting and collecting fluorescence emission from the fiber optic probe. Combination tapered fiber probes are produced by tube-etching method and the best tapered ratio of the probe determined is approximately 0.37. Calibration curves obtained for 2,4-dichlorophenoxyacetic acid (2,4-D) and Microcystin-LR (MC-LR) have detection limits of 0.09 mu g L-1 and 0.03 mu g L-1, respectively. The 50% inhibition concentration (IC50) for MC-LR and 2,4-D were 1.12 +/- 0.01 mu g L-1 and 3.81 +/- 0.03 mu g L-1, respectively. A reusable immunosurface is provided via the covalent attachment of the analyte derivative to a self-assembled monolayer formed onto the fiber optic probe. The regeneration of the sensor surface allows the performance of more than 100 assay cycles within an analysis time of about 20 min for each assay cycle. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:952 / 958
页数:7
相关论文
共 25 条
[1]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[2]   AN EVANESCENT-WAVE BIOSENSOR .1. FLUORESCENT SIGNAL ACQUISITION FROM STEP-ETCHED FIBER OPTIC PROBES [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (06) :578-584
[3]   REMOTE FIBER-OPTIC BIOSENSORS BASED ON EVANESCENT-EXCITED FLUORO-IMMUNOASSAY - CONCEPT AND PROGRESS [J].
ANDRADE, JD ;
VANWAGENEN, RA ;
GREGONIS, DE ;
NEWBY, K ;
LIN, JN .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1985, 32 (07) :1175-1179
[4]   Sampling of polar pesticides from water matrices [J].
Barcelo, D ;
Hennion, MC .
ANALYTICA CHIMICA ACTA, 1997, 338 (1-2) :3-18
[5]   Optical multiple-analyte immunosensor for water pollution control [J].
Barzen, C ;
Brecht, A ;
Gauglitz, G .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (04) :289-295
[6]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[7]   Detection of Escherichia coli O157:H7 in 10-and 25-gram ground beef samples with an evanescent-wave biosensor with silica and polystyrene waveguides [J].
DeMarco, DR ;
Lim, DV .
JOURNAL OF FOOD PROTECTION, 2002, 65 (04) :596-602
[8]   Portable multichannel fiber optic biosensor for field detection [J].
Golden, JP ;
Saaski, EW ;
ShriverLake, LC ;
Anderson, GP ;
Ligler, FS .
OPTICAL ENGINEERING, 1997, 36 (04) :1008-1013
[9]   AN EVANESCENT-WAVE BIOSENSOR .2. FLUORESCENT SIGNAL ACQUISITION FROM TAPERED FIBER OPTIC PROBES [J].
GOLDEN, JP ;
ANDERSON, GP ;
RABBANY, SY ;
LIGLER, FS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (06) :585-591
[10]   Optical immunosensors for environmental monitoring:: How far have we come? [J].
Gonzalez-Martinez, M. A. ;
Puchades, R. ;
Maquieira, A. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (01) :205-218