Performance Analysis of Passive Resonance Circuit Breakers in HVDC Systems

被引:5
作者
Ghavami, Sadegh [1 ]
Razi-Kazemi, Ali Asghar [1 ]
Niayesh, Kaveh [2 ]
机构
[1] KN Toosi Univ Technol, Dept Elect Engn, Tehran 16315, Iran
[2] Norwegian Univ Sci & Technol, Dept Elect Power Engn, N-7491 Trondheim, Norway
来源
IEEE SYSTEMS JOURNAL | 2022年 / 16卷 / 03期
关键词
HVDC transmission; Integrated circuit modeling; Genetic algorithms; Circuit breakers; RLC circuits; Mathematical model; Switches; Arc model; black-box model; circuit breaker (CB) model; HVDC system; passive resonance; protection tool; CURRENT INTERRUPTION; ARC;
D O I
10.1109/JSYST.2021.3102393
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
High voltage direct current (HVDC) systems have been increasingly employed to provide a connection amongst various energy sources, especially renewable energies. In order to switch the load current in these systems, the passive resonance breaker (PRB) is employed as a transfer switch. The interruption capability of the PRBs is highly dependent on the dynamic behavior of the arc in this system. Accordingly, this article presents a black-box high-degree of freedom arc-model based on Schwarz and the genetic algorithm as a heuristic optimization to follow the characteristics of the static and quasi-static arc regarding the oscillation frequency of the interruption current. The model has been verified by the published experiments. Subsequently, the PRB operation has been quantified based on the state-space approach along with an accurate dynamic arc model to follow in a wide frequency range of the arc current. The results are indicated that the amplification coefficient alone is insufficient to determine the interruption capability of these protection tools. Therefore, this article attempts to quantitatively determine the interruption capability curve by introducing criteria, such as Delta t PZ (peak to zero time-interval), diarc/dtCZ- and duarc/dtCZ+ to obtain the origins of the interruption failure probabilities and dimensioning of the PRBs with respect to the interruption limits for gas blast CBs.
引用
收藏
页码:4380 / 4388
页数:9
相关论文
共 36 条
[1]  
[Anonymous], 1993, Electra, P40
[2]  
Asplund G., 2013, CIGRE TB 533-Working Group B4.52-HVDC Grid Feasibility Study
[3]   DEVELOPMENT OF A 500KV AIRBLAST HVDC CIRCUIT-BREAKER [J].
BACHMANN, B ;
MAUTHE, G ;
RUOSS, E ;
LIPS, HP ;
PORTER, J ;
VITHAYATHIL, J .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (09) :2460-2466
[4]   Test Circuits for HVDC Circuit Breakers [J].
Belda, N. A. ;
Smeets, R. P. P. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (01) :285-293
[5]   Experimental Investigation of Electrical Stresses on the Main Components of HVDC Circuit Breakers [J].
Belda, Nadew Adisu ;
Smeets, Rene Peter Paul ;
Nijman, Roy Maarten .
IEEE TRANSACTIONS ON POWER DELIVERY, 2020, 35 (06) :2762-2771
[6]  
Bonin E. v, 1970, P INT C LARG HIGH TE, P15
[7]  
Bonkarev M., 2014, CONCEPT ANAL HIGH VO
[8]   Controlling the differential resistance of axial blown arcs [J].
Bort, L. S. J. ;
Vonesch, M. ;
Franck, C. M. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2019, 52 (45)
[9]   Fault Current Interruption in Multiterminal HVDC Networks [J].
Bucher, Matthias K. ;
Franck, Christian M. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (01) :87-95
[10]   A NEW DC BREAKER USED AS METALLIC RETURN TRANSFER BREAKER [J].
COURTS, AL ;
VITHAYATHIL, JJ ;
HINGORANI, NG ;
PORTER, JW ;
GORMAN, JG ;
KIMBLIN, CW .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (10) :4112-4121