Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality

被引:32
作者
Renne, Walter [1 ]
Wolf, Bethany [2 ]
Kessler, Raymond [1 ]
McPherson, Karen [1 ]
Mennito, Anthony S. [1 ]
机构
[1] Med Univ S Carolina, Coll Dent Med, Dept Oral Rehabil, Charleston, SC 29414 USA
[2] Med Univ S Carolina, Coll Dent Med, Dept Biostat & Epidemiol, Charleston, SC 29414 USA
关键词
FIXED DENTAL PROSTHESES; LUTING AGENTS; INTERNAL FIT; CLINICAL FIT; CAST CROWNS; ADAPTATION; ACCURACY; COPINGS;
D O I
10.1111/jerd.12148
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PurposeThis study evaluated the marginal gap of crowns fabricated using two new chairside computer-aided design/computer-aided manufacturing systems on preparations completed by clinicians with varying levels of expertise to identify whether common preparation errors affect marginal fit. The null hypothesis is that there is no difference in the mean marginal gaps of restorations of varying qualities and no difference in the mean marginal gap size between restorations fabricated using the PlanScan (D4D, Richardson, TX, USA) and the CEREC Omnicam (Sirona, Bensheim, Germany). Material and MethodsThe fit of 80 lithium disilicate crowns fabricated with the E4D PlanScan or CEREC Omnicam systems on preparations of varying quality were examined for marginal fit by using the replica technique. These same preparations were then visually examined against common criteria for anterior all-ceramic restorations and placed in one of four categories: excellent, good, fair, and poor. Linear mixed modeling was used to evaluate associations between marginal gap, tooth preparation rating, and fabrication machine. ResultsThe fit was not significantly different between both systems across all qualities of preparation. The average fit was 104m for poor-quality preparations, 87.6m for fair preparations, 67.2m for good preparations, and 36.6m for excellent preparations. ConclusionThe null hypothesis is rejected. It can be concluded that preparation quality has a significant impact on marginal gap regardless of which system is used. However, no significant difference was found when comparing the systems to each other. Clinical SignificanceWithin the limitations of this in vitro study, it can be concluded that crown preparation quality has a significant effect on marginal gap of the restoration when the clinician uses either CEREC Omnicam or E4D PlansScan.
引用
收藏
页码:194 / 202
页数:9
相关论文
共 39 条
  • [1] Adair P.J., 1984, INT J PERIODONT REST, V4, P33
  • [2] Volumetric Misfit in CAD/CAM and Cast Implant Frameworks: A University Laboratory Study
    Almasri, Riad
    Drago, Carl J.
    Siegel, Sharon Crane
    Hardigan, Patrick C.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (04): : 267 - 274
  • [3] Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    Almeida e Silva, Junio S.
    Erdelt, Kurt
    Edelhoff, Daniel
    Araujo, Elito
    Stimmelmayr, Michael
    Cardoso Vieira, Luiz Clovis
    Gueth, Jan-Frederik
    [J]. CLINICAL ORAL INVESTIGATIONS, 2014, 18 (02) : 515 - 523
  • [4] 3D and 2D Marginal Fit of Pressed and CAD/CAM Lithium Disilicate Crowns Made from Digital and Conventional Impressions
    Anadioti, Evanthia
    Aquilino, Steven A.
    Gratton, David G.
    Holloway, Julie A.
    Denry, Isabelle
    Thomas, Geb W.
    Qian, Fang
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2014, 23 (08): : 610 - 617
  • [5] [Anonymous], 1970, Guide to Dental Materials and Devices, V5 th, P87, DOI DOI 10.6028/NBS.SP.571
  • [6] Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth
    Beschnidt, SM
    Strub, JR
    [J]. JOURNAL OF ORAL REHABILITATION, 1999, 26 (07) : 582 - 593
  • [7] Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
    Bindl, A
    Mörmann, WH
    [J]. JOURNAL OF ORAL REHABILITATION, 2005, 32 (06) : 441 - 447
  • [8] Clinical fit of Procera AllCeram crowns
    Boening, KW
    Wolf, BH
    Schmidt, AE
    Kästner, K
    Walter, MH
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2000, 84 (04) : 419 - 424
  • [9] NONCAST TITANIUM RESTORATIONS IN FIXED PROSTHODONTICS
    BOENING, KW
    WALTER, MH
    REPPEL, PD
    [J]. JOURNAL OF ORAL REHABILITATION, 1992, 19 (03) : 281 - 287
  • [10] The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    Brawek, Petya K.
    Wolfart, Stefan
    Endres, Lutz
    Kirsten, Armin
    Reich, Sven
    [J]. CLINICAL ORAL INVESTIGATIONS, 2013, 17 (09) : 2119 - 2125