Background: The use of larger femoral heads has been proposed to reduce the risk of dislocation after total hip arthroplasty, but there is a lack of evidence to support this proposal. The aim of this multicenter randomized controlled trial was to determine whether the incidence of dislocation one year after total hip arthroplasty is significantly lower in association with the use of a 36-mm femoral head articulation as compared with a 28-mm articulation. Methods: Six hundred and forty-four middle-aged and elderly patients undergoing primary or revision arthroplasty were randomized intraoperatively to receive either a 36 or 28-mm metal femoral head on highly cross-linked polyethylene. Patients who were at high risk of dislocation (including those with dementia and neuromuscular disease) and those undergoing revision for the treatment of recurrent hip dislocation or infection were excluded. Patients were stratified according to other potential risk factors for dislocation, including diagnosis and age. Diagnosis of hip dislocation required confirmation by a physician and radiographic evidence of a dislocation. Results: Overall, at one year of follow-up, hips with a 36-mm femoral head articulation had a significantly lower incidence of dislocation than did those with a 28-mm articulation (1.3% [four of 299] compared with 5.4% [seventeen of 316]; difference, 4.1% [95% confidence interval, 1.2% to 7.2%]) when controlling for the type of procedure (primary or revision) (p = 0.012). The incidence of dislocation following primary arthroplasty was also significantly lower for hips with a 36-mm femoral head articulation than for those with a 28-mm articulation (0.8% [two of 258] compared with 4.4% [twelve of 275]; difference. 3.6% [95% confidence interval, 0.9% to 6.8%]) (p = 0.024). The incidence of dislocation following revision arthroplasty was 4.9% (two of forty-one) for hips with a 36-mm articulation and 12.2% (five of forty-one) for hips with a 28-mm articulation; this difference was not significant with the relatively small sample size of the revision group (difference, 7.3% [95% confidence interval, -5.9% to 21.1%]) (p = 0.273). Conclusions: Compared with a 28-mm femoral head articulation, a larger 36-mm articulation resulted in a significantly decreased incidence of dislocation in the first year following primary total hip arthroplasty. However, before a 36-mm metal-on-highly cross-linked polyethylene articulation is widely recommended, the incidence of late dislocation, wear, periprosthetic osteolysis, and liner fracture should be established. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
引用
收藏
页码:1095 / 1102
页数:8
相关论文
共 50 条
  • [41] A prospective randomized controlled trial comparing CT- based planning with conventional total hip arthroplasty versus robotic arm- assisted total hip arthroplasty
    Fontalis, A.
    Kayani, B.
    Plastow, R.
    Giebaly, D. E.
    Tahmassebi, J.
    Haddad, I. C.
    Chambers, A.
    Mancino, F.
    Konan, S.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2024, 106B (04): : 324 - 335
  • [42] Polyethylene Wear With Ceramic and Metal Femoral Heads at 5 Years: A Randomized Controlled Trial With Radiostereometric Analysis
    Bergvinsson, Halldor
    Sundberg, Martin
    Flivik, Gunnar
    JOURNAL OF ARTHROPLASTY, 2020, 35 (12): : 3769 - 3776
  • [43] Bone wax reduces blood loss after total hip arthroplasty: a prospective, randomized controlled study
    Li, Hao
    Huang, Chao
    Ding, Zi-Chuan
    Liu, Zun-Han
    Zhao, En-Ze
    Zhou, Zong-Ke
    FRONTIERS IN MEDICINE, 2023, 10
  • [44] Large Metal Heads and Vitamin E Polyethylene Increase Frictional Torque in Total Hip Arthroplasty
    Meneghini, R. Michael
    Lovro, Luke R.
    Wallace, Joseph M.
    Ziemba-Davis, Mary
    JOURNAL OF ARTHROPLASTY, 2016, 31 (03): : 710 - 714
  • [45] Capsular resection versus capsular repair in direct anterior approach for total hip arthroplasty: a randomized controlled trial
    Vandeputte, F-J
    Vanbiervliet, J.
    Sarac, C.
    Driesen, R.
    Corten, K.
    BONE & JOINT JOURNAL, 2021, 103B (02): : 321 - 328
  • [46] The effect of femoral head size on functional outcome in primary total hip arthroplasty: a single-blinded randomised controlled trial
    Hanna, Sammy A.
    Sewell, Mathew D.
    Sri-Ram, Kesavan
    Miles, Jonathan
    Aston, William J. S.
    Pollock, Robin C.
    Carrington, Richard W. J.
    Briggs, Timothy W. R.
    HIP INTERNATIONAL, 2012, 22 (06) : 592 - 597
  • [47] Large Femoral Heads in Total Hip Arthroplasty With Vitamin E Highly Cross-Linked Polyethylene: Head Penetration Rates Compared to Highly Cross-Linked Polyethylene
    Nielson, Trent
    Owens, Garrett
    Miller, Brandon
    Meneghini, Ethan
    Deckard, Evan R.
    Meneghini, R. Michael
    JOURNAL OF ARTHROPLASTY, 2022, 37 (07): : S685 - S691
  • [48] Safety of using a large femoral head on thin polyethylene for total hip arthroplasty based on different types of polyethylene
    Do, Min Uk
    Moon, Nam Hoon
    Suh, Kuen Tak
    Kim, Jung Shin
    Lee, Sang-Min
    Shin, Won Chul
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [49] Influence of Preoperative Patient Education on the Risk of Dislocation After Primary Total Hip Arthroplasty
    Luebbeke, Anne
    Suva, Domizio
    Perneger, Thomas
    Hoffmeyer, Pierre
    ARTHRITIS & RHEUMATISM-ARTHRITIS CARE & RESEARCH, 2009, 61 (04): : 552 - 558
  • [50] Factors affecting impingement and dislocation after total hip arthroplasty - Computer simulation analysis
    Shoji, Takeshi
    Ota, Yuki
    Saka, Hideki
    Murakami, Hiroaki
    Takahashi, Wakan
    Yamasaki, Takuma
    Yasunaga, Yuji
    Iwamori, Hiroshi
    Adachi, Nobuo
    CLINICAL BIOMECHANICS, 2020, 80