Comparison of preoperative angle kappa measurements in the eyes of cataract patients obtained from Pentacam Scheimpflug system, optical low-coherence reflectometry, and ray-tracing aberrometry

被引:14
作者
Qin, Miaomiao [1 ]
Yuan, Yurong [1 ]
Wang, Ying [1 ]
Li, Pengfei [1 ]
Chen, Wei [1 ]
Wang, Yong [1 ]
Yang, Mei [1 ]
Wu, Jian [1 ]
Ji, Min [1 ]
Luo, Jiawei [1 ]
Tang, Jiamin [1 ]
Chen, Xiaojuan [1 ]
Huang, Yemeng [1 ]
Guan, Huaijin [1 ]
机构
[1] Nantong Univ, Inst Eye, Affiliated Hosp, 20 Xisi Rd, Nantong 226001, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Angle kappa; Cataract; Pentacam; Lenstar; iTrace; ORBSCAN-II; REPRODUCIBILITY; REPEATABILITY;
D O I
10.1186/s12886-021-02116-w
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Angle kappa plays a vital role in the implantation of multifocal intraocular lens (MIOL). Large angle kappa is related to a higher risk of postoperative photic phenomena. This study aims to compare preoperative angle kappa in the eyes of cataract patients obtained from the Pentacam Scheimpflug system (Pentacam), optical low-coherence reflectometry (Lenstar), and ray-tracing aberrometry (iTrace). Methods One hundred thirteen eyes of 113 patients with cataracts were included. Each eye was examined 3 times using all devices to obtain angle kappa and pupil diameter. When considering dependent eyes for one individual, angle kappa in both right eyes and left eyes should be analysed separately. The repeatability and reproducibility were evaluated using the within-subject standard deviation (Sw), repeatability (2.77 Sw), and intraclass correlation coefficient (ICC). The difference, correlation, and agreement between devices were evaluated by paired t-tests, Pearson tests, and Bland-Altman analysis, respectively. Results Intraoperator repeatability and interoperator and intersession reproducibility of angle kappa showed an Sw of less than 0.05 mm, a 2.77 Sw of 0.14 mm or less, and an ICC of more than 0.96. Angle kappa was not significantly different between Pentacam and Lenstar (P > 0.05), while angle kappa was significantly different between Pentacam and iTrace and between Lenstar and iTrace (P < 0.05). There was a strong correlation between Pentacam and Lenstar for angle kappa (r =0.907 to 0.918) and a weak or moderate correlation between Pentacam and iTrace and between Lenstar and iTrace (r =0.292 to 0.618). There were narrow 95% limits of agreement (LoA) between Pentacam and Lenstar for angle kappa and wide 95% LoA between Pentacam and iTrace and between Lenstar and iTrace. No significant differences in pupil diameter were found between Pentacam and Lenstar in either eye (P > 0.05). Positive angle kappa (nasal light reflex) was found in most cataract patients (79.25% to 84.91%) through 3 different devices in both eyes. Conclusions The 3 devices provided high intraoperator repeatability and interoperator and intersession reproducibility for angle kappa measurements. The measurement of preoperative angle kappa in the eyes of patients with cataracts by Pentacam and Lenstar has good agreement.
引用
收藏
页数:9
相关论文
共 26 条
[1]   Measurement of angle kappa with synoptophore and Orbscan II in a normal population [J].
Basmak, Hikmet ;
Sahin, Afsun ;
Yildirim, Nilgun ;
Papakostas, Thanos D. ;
Kanellopoulos, A. John .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (05) :456-460
[2]   The Angle Kappa in Strabismic Individuals [J].
Basmak, Hikmet ;
Sahin, Afsun ;
Yildirim, Nilgun ;
Saricicek, Tuncer ;
Yurdakul, Sumru .
STRABISMUS, 2007, 15 (04) :193-196
[3]  
Bland JM., FREQUENTLY ASKED QUE
[4]   Estimation of angle kappa and pupil barycentre configuration in myopic tilted disc syndrome [J].
Cankaya, Cem ;
Ozsoy, Ercan ;
Demirel, Ersin Ersan ;
Polat, Nihat ;
Gunduz, Abuzer .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (02) :192-196
[5]   Intraocular straylight after implantation of the multifocal AcrySof ReSTOR SA60D3 diffractive [J].
de Vries, Niels E. ;
Franssen, Luuk ;
Webers, Carroll A. B. ;
Tahzib, Nayyirih G. ;
Cheng, Yanny Y. Y. ;
Hendrikse, Fred ;
Tjia, Khiun F. ;
van den Berg, Tom J. T. P. ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (06) :957-962
[6]   Measurement of angle Kappa with Orbscan II and Galilei G4: effect of accommodation [J].
Dominguez-Vicent, Alberto ;
Monsalvez-Romin, Daniel ;
Perez-Vives, Cari ;
Ferrer-Blasco, Teresa ;
Montes-Mico, Robert .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (02) :249-255
[7]   Pupil center shift relative to the coaxially sighted corneal light reflex under natural and pharmacologically dilated conditions [J].
Erdem, Uzeyir ;
Muftuoglu, Orkun ;
Gundogan, Fatih Cakir ;
Sobaci, Gungor ;
Bayer, Atilla .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (05) :530-538
[8]   Influence of angle kappa and angle alpha on visual quality after implantation of multifocal intraocular lenses [J].
Fu, Yana ;
Kou, Jiaojiao ;
Chen, Dongjie ;
Wang, Dandan ;
Zhao, Yinyin ;
Hu, Man ;
Lin, Xiaolei ;
Dai, Qi ;
Li, Junhua ;
Zhao, Yun-e .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) :1258-1264
[9]   Influence of angle κ on visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens [J].
Garzon, Nuria ;
Garcia-Montero, Maria ;
Lopez-Artero, Esther ;
Albarran-Diego, Cesar ;
Perez-Cambrod, Rafael ;
Illarramendi, Igor ;
Poyales, Francisco .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (05) :721-727
[10]   Angle Kappa Measurements: Normal Values in Healthy Iranian Population Obtained With the Orbscan II [J].
Gharaee, Hamid ;
Shafiee, Masoud ;
Hoseini, Rafie ;
Abrishami, Mojtaba ;
Abrishami, Yalda ;
Abrishami, Mostafa .
IRANIAN RED CRESCENT MEDICAL JOURNAL, 2015, 17 (01) :1-5