In this study, field emission AES and small-area XPS techniques were used to analyze surface composition and depth profiles on discolored bondpads to identify possible root causes for nonstick failure. In wafer fabrication, the discolored bondpad problem was found in the fab process with hot Al alloy metallization, which had resulted in nonstick failure during the assembly bonding process. Analytical results indicated that discolored bondpads with nonstick failure might be due to TiN residue introduced during the bondpad opening etching process. The possible root cause of TiN residue on bondpads was then confirmed to be arisen from ARC (TiN) layer underetched during the bondpad opening etching process. The solution to eliminate TiN residue on bondpads was taken to increase the etch time at the bondpad opening fab process.
引用
收藏
页码:435 / 439
页数:5
相关论文
共 50 条
[21]   STRUCTURE-ANALYSIS WITH X-RAY PHOTOELECTRON-SPECTROSCOPY (XPS) AND AUGER-ELECTRON SPECTROSCOPY (AES) [J].
EBEL, H ;
FALK, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1975, 273 (05) :368-373
[22]   APPLICATION OF X-RAY PHOTOELECTRON SPECTROSCOPY TO CHEMICAL ANALYSIS [J].
HELMER, JC .
APPLIED SPECTROSCOPY, 1969, 23 (06) :671-&
[23]   Surface analysis of bismuth titanate by Auger and X-ray photoelectron spectroscopy [J].
Jovalekic, C. ;
Zdujic, M. ;
Atanasoska, Lj. .
Journal of Alloys and Compounds, 2009, 469 (1-2) :441-444
[24]   Surface analysis of bismuth titanate by Auger and X-ray photoelectron spectroscopy [J].
Jovalekic, C. ;
Zdujic, M. ;
Atanasoska, Lj. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2009, 469 (1-2) :441-444
[25]   AlN/GaAs interface analyses by auger electron spectroscopy and x-ray photoelectron spectroscopy [J].
Cao, Xin ;
Luo, Jinsheng ;
Chen, Tangsheng ;
Chen, Kejin .
Pan Tao Ti Hsueh Pao/Chinese Journal of Semiconductors, 1999, 20 (07) :539-542
[26]   Some issues in quantitative x-ray photoelectron Spectroscopy and auger-electron spectroscopy [J].
Powell, CJ ;
Conny, JM ;
Jablonski, A .
STATE-OF-THE ART APPLICATION OF SURFACE AND INTERFACE ANALYSIS METHODS TO ENVIRONMENTAL MATERIALS INTERACTIONS: IN HONOR OF JAMES E. CASTLE'S 65TH YEAR, PROCEEDINGS, 2001, 2001 (05) :15-45
[28]   X-RAY PHOTOELECTRON-SPECTROSCOPY (XPS) AND AUGER-ELECTRON SPECTROSCOPY (AES) [J].
LANGERON, JP .
VIDE-SCIENCE TECHNIQUE ET APPLICATIONS, 1988, 43 (244) :613-627
[29]   Auger electron spectroscopy and x-ray photoelectron spectroscopy analysis of angle of incidence effects of ion beam nitridation of GaAs [J].
Pan, JS ;
Huan, CHA ;
Wee, ATS ;
Tan, HS ;
Tan, KL .
JOURNAL OF MATERIALS RESEARCH, 1998, 13 (07) :1799-1807
[30]   Auger electron spectroscopy and x-ray photoelectron spectroscopy analysis of angle of incidence effects of ion beam nitridation of GaAs [J].
J. S. Pan ;
C. H. A. Huan ;
A. T. S. Wee ;
H. S. Tan ;
K. L. Tan .
Journal of Materials Research, 1998, 13 :1799-1807