Screening of sperm velocity by fluid mechanical characteristics of a cyclo-olefin polymer microfluidic sperm-sorting device

被引:27
作者
Matsuura, Koji [1 ]
Takenami, Mami [1 ]
Kuroda, Yuka [1 ]
Hyakutake, Toru [3 ]
Yanase, Shinichiro [2 ]
Naruse, Keiji [1 ]
机构
[1] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Okayama 7008530, Japan
[2] Okayama Univ, Grad Sch Nat Sci & Technol, Okayama 7008530, Japan
[3] Yokohama Natl Univ, Fac Engn, Yokohama, Kanagawa 240, Japan
关键词
laminar flow; linear velocity; microfluidic sperm sorting; motility; FERTILIZATION RATES; DNA INTEGRITY; MOTILE SPERM; SEPARATION; SORTER;
D O I
10.1016/j.rbmo.2011.09.005
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
The microfluidic sperm-sorting (MFSS) device is a promising advancement for assisted reproductive technology. Previously, poly(dimethylsiloxiane) and quartz MFSS devices were developed and used for intracytoplasmic sperm injection. However, these disposable devices were not clinically suitable for assisted reproduction, so a cyclo-olefin polymer MFSS (COP-MFSS) device was developed. By micromachining, two microfluidic channels with different heights and widths (chip A: 0.3 x 0.5 mm; chip B: 0.1 x 0.6 mm) were prepared. Sorted sperm concentrations were similar in both microfluidic channels. Linear-velocity distribution using the microfluidic channel of chip B was higher than that of chip A. Using confocal fluorescence microscopy, it was found that the highest number of motile spermatozoa swam across the laminar flow at the bottom of the microfluidic channel. The time required to swim across the laminar flow was longer at the bottom and top of the microfluidic channels than in the middle because of the low fluid velocity. These results experimentally demonstrated that the width of microfluidic channels should be increased in the region of laminar flow from the semen inlet to the outlet for unsorted spermatozoa to selectively recover spermatozoa with high linear velocity. (C) 2011, Reproductive Healthcare Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:109 / 115
页数:7
相关论文
共 17 条
[1]   Passively driven integrated microfluidic system for separation of motile sperm [J].
Cho, BS ;
Schuster, TG ;
Zhu, XY ;
Chang, D ;
Smith, GD ;
Takayama, S .
ANALYTICAL CHEMISTRY, 2003, 75 (07) :1671-1675
[2]   Tracking sperm in three-dimensions [J].
Corkidi, G. ;
Taboada, B. ;
Wood, C. D. ;
Guerrero, A. ;
Darszon, A. .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2008, 373 (01) :125-129
[3]   Ca2+-stores in sperm: their identities and functions [J].
Costello, Sarah ;
Michelangeli, Francesco ;
Nash, Katherine ;
Lefievre, Linda ;
Morris, Jennifer ;
Machado-Oliveira, Gisela ;
Barratt, Christopher ;
Kirkman-Brown, Jackson ;
Publicover, Stephen .
REPRODUCTION, 2009, 138 (03) :425-437
[4]   The effects of antioxidant supplementation during Percoll preparation on human sperm DNA integrity [J].
Hughes, CM ;
Lewis, SEM ;
McKelvey-Martin, VJ ;
Thompson, W .
HUMAN REPRODUCTION, 1998, 13 (05) :1240-1247
[5]   Application of a numerical simulation to improve the separation efficiency of a sperm sorter [J].
Hyakutake, Toru ;
Hashimoto, Yuki ;
Yanase, Shinichiro ;
Matsuura, Koji ;
Naruse, Keiji .
BIOMEDICAL MICRODEVICES, 2009, 11 (01) :25-33
[6]  
Jeyendran R.S., 2003, ART SCI ASSISTED REP, P213
[7]   PURIFICATION OF HUMAN-SPERM BY A DISCONTINUOUS PERCOLL DENSITY GRADIENT WITH AN INNERCOLUMN [J].
KANEKO, S ;
OSHIO, S ;
KOBANAWA, K ;
KOBAYASHI, T ;
MOHRI, H ;
IIZUKA, R .
BIOLOGY OF REPRODUCTION, 1986, 35 (04) :1059-1063
[8]  
LIU DY, 1991, J ANDROL, V12, P231
[9]   Sperm motion in a microfluidic fertilization device [J].
Lopez-Garcia, M. d. C. ;
Monson, R. L. ;
Haubert, K. ;
Wheeler, M. B. ;
Beebe, D. J. .
BIOMEDICAL MICRODEVICES, 2008, 10 (05) :709-718
[10]   SPERM PREPARATION TECHNIQUES AND IATROGENIC FAILURES OF INVITRO FERTILIZATION [J].
MORTIMER, D .
HUMAN REPRODUCTION, 1991, 6 (02) :173-176