Chemcatcher® and DGT passive sampling devices for regulatory monitoring of trace metals in surface water

被引:50
作者
Allan, Ian J. [1 ,2 ]
Knutsson, Jesper [3 ]
Guigues, Nathalie [4 ]
Mills, Graham A. [5 ]
Fouillac, Anne-Marie [4 ]
Greenwood, Richard [2 ]
机构
[1] Norwegian Inst Water Res, N-0349 Oslo, Norway
[2] Univ Portsmouth, Sch Biol Sci, Portsmouth PO1 2DY, Hants, England
[3] Chalmers, SE-41296 Gothenburg, Sweden
[4] Bur Rech Geol & Minieres, F-45060 Orleans, France
[5] Univ Portsmouth, Sch Pharm & Biomed Sci, Portsmouth PO1 2DT, Hants, England
来源
JOURNAL OF ENVIRONMENTAL MONITORING | 2008年 / 10卷 / 07期
关键词
D O I
10.1039/b802581a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work aimed to evaluate whether the performance of passive sampling devices in measuring time-weighted average (TWA) concentrations supports their application in regulatory monitoring of trace metals in surface waters, such as for the European Union's Water Framework Directive (WFD). The ability of the Chemcatcher (R) and the diffusive gradient in thin film (DGT) device sampler to provide comparable TWA concentrations of Cd, Cu, Ni, Pb and Zn was tested through consecutive and overlapping deployments (7-28 days) in the River Meuse (The Netherlands). In order to evaluate the consistency of these TWA labile metal concentrations, these were assessed against total and filtered concentrations measured at relatively high frequencies by two teams using standard monitoring procedures, and metal species predicted by equilibrium speciation modeling using Visual MINTEQ. For Cd and Zn, the concentrations obtained with filtered water samples and the passive sampling devices were generally similar. The samplers consistently underestimated filtered concentrations of Cu and Ni, in agreement with their respective predicted speciation. For Pb, a small labile fraction was mainly responsible for low sampler accumulation and hence high measurement uncertainty. While only the high frequency of spot sampling procedures enabled the observation of higher Cd concentrations during the first 14 days, consecutive DGT deployments were able to detect it and provide a reasonable estimate of ambient concentrations. The range of concentrations measured by spot and passive sampling, for exposures up to 28 days, demonstrated that both modes of monitoring were equally reliable. Passive sampling provides information that cannot be obtained by a realistic spot sampling frequency and this may impact on the ability to detect trends and assess monitoring data against environmental quality standards when concentrations fluctuate.
引用
收藏
页码:821 / 829
页数:9
相关论文
共 31 条
[1]   Evaluation of the Chemcatcher and DGT passive samplers for monitoring metals with highly fluctuating water concentrations [J].
Allan, Ian J. ;
Knutsson, Jesper ;
Guigues, Nathalie ;
Mills, Graham A. ;
Fouillac, Anne-Marie ;
Greenwood, Richard .
JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (07) :672-681
[2]   Strategic monitoring for the European Water Framework Directive [J].
Allan, Ian J. ;
Mills, Graham A. ;
Vrana, Branislav ;
Knutsson, Jesper ;
Holmberg, Arne ;
Guigues, Nathalie ;
Laschi, Serena ;
Fouillac, Anne-Marie ;
Greenwood, Richard .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (07) :704-715
[3]   A "toolbox" for biological and chemical monitoring requirements for the European Union's Water Framework Directive [J].
Allan, IJ ;
Vrana, B ;
Greenwood, R ;
Mills, GA ;
Roig, B ;
Gonzalez, C .
TALANTA, 2006, 69 (02) :302-322
[4]   A comparison of copper speciation measurements with the toxic responses of three sensitive freshwater organisms [J].
Apte, SC ;
Batley, GE ;
Bowles, KC ;
Brown, PL ;
Creighton, N ;
Hales, LT ;
Hyne, RV ;
Julli, M ;
Markich, SI ;
Pablo, F ;
Rogers, NJ ;
Stauber, JL ;
Wilde, K .
ENVIRONMENTAL CHEMISTRY, 2005, 2 (04) :320-330
[5]   Performance of an in situ passive sampling system for metals in stormwater [J].
Blom, LB ;
Morrison, GM ;
Kingston, J ;
Mills, GA ;
Greenwood, R ;
Pettersson, TJR ;
Rauch, S .
JOURNAL OF ENVIRONMENTAL MONITORING, 2002, 4 (02) :258-262
[6]   Calibrating the uptake kinetics of semipermeable membrane devices using exposure standards [J].
Booij, K ;
Sleiderink, HM ;
Smedes, F .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1998, 17 (07) :1236-1245
[7]  
*BRIT STAND I, 612006 BRIT STAND I
[8]   Monitoring metal speciation in the rivers meuse and Rhine using DGT [J].
Cleven, R ;
Nur, Y ;
Krystek, P ;
Van den Berg, G .
WATER AIR AND SOIL POLLUTION, 2005, 165 (1-4) :249-263
[9]   In situ measurements of labile Cu, Cd and Mn in river waters using DGT [J].
Denney, S ;
Sherwood, J ;
Leyden, J .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 239 (1-3) :71-80
[10]   Evaluation of the in situ, time-integrated DGT technique by monitoring changes in heavy metal concentrations in estuarine waters [J].
Dunn, R. J. K. ;
Teasdale, P. R. ;
Warnken, J. ;
Arthur, J. M. .
ENVIRONMENTAL POLLUTION, 2007, 148 (01) :213-220