CsI(Tl)/plastic phoswich detector enhanced in low-energy gamma-ray detection

被引:5
|
作者
Yamasoto, K [1 ]
Tsutsumi, M [1 ]
Oishi, T [1 ]
Yoshizawa, M [1 ]
Yoshida, M [1 ]
机构
[1] Japan Atom Energy Res Inst, Dept Hlth Phys, Tokai, Ibaraki 3191195, Japan
关键词
large-area plastic scintillation detector; low-energy region; thin plate CsI(Tl) scintillator; phoswich detector; rise-time discrimination technique; minimum detectable activity;
D O I
10.1016/j.nima.2005.05.054
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A phoswich detector composed of a thin plate CsI(TI) scintillator and a plastic scintillator (BC-400) has been designed and evaluated in order to improve the sensitivity in the low-energy region of a large-area plastic scintillation detector. This newly designed phoswich detector can be applied to both gross gamma measurement and energy spectrometry for low-energy gamma-ray emitters. Judging by estimations of minimum detectable activity, the lower measurable energy of a large-area plastic scintillation detector can be expanded down to a few tens of keV by adding a thin plate CsI(TI) scintillator. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:609 / 615
页数:7
相关论文
共 50 条
  • [1] A BGO-CSI(TL) PHOSWICH - A NEW DETECTOR FOR X-RAY AND GAMMA-RAY ASTRONOMY
    COSTA, E
    MASSARO, E
    PIRO, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 243 (2-3): : 572 - 577
  • [2] Gamma-ray imaging with a Si/CsI(Tl) compton detector
    Hoover, A. S.
    Sullivan, J. P.
    Baird, B.
    Brumby, S. P.
    Kippen, R. M.
    McCluskey, C. W.
    Rawool-Sullivan, M. W.
    Sorensen, E. B.
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (12) : 1648 - 1654
  • [3] A PHOSWICH ANGER CAMERA FOR HARD X-RAY AND LOW-ENERGY GAMMA-RAY ASTRONOMY
    SOOD, RK
    MANCHANDA, RK
    STAUBERT, R
    KENDZIORRA, E
    MCNAMARA, K
    SCIENTIFIC BALLOONING, 1996, 17 (09): : 87 - 90
  • [4] A computational modelling of low-energy gamma ray detection efficiency of a cylindrical NaI(Tl) detector
    Ahmadi, S.
    Ashrafi, S.
    Yazdansetad, F.
    Roshanshah, N.
    Tarim, U. Akar
    Gurler, O.
    RADIATION PHYSICS AND CHEMISTRY, 2021, 188
  • [5] DETECTION OF A FLARING LOW-ENERGY GAMMA-RAY SOURCE
    BHATTACHARYA, D
    OWENS, A
    ASTROPHYSICAL JOURNAL, 1994, 430 (01): : 371 - 375
  • [6] A new CdZnTe detector system for low-energy gamma-ray measurement
    Johansen, GA
    Abro, E
    SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) : 493 - 498
  • [7] SPECTROMETER WITH A GE(LI)-DETECTOR FOR LOW-ENERGY GAMMA-RAY QUANTA
    VYLOV, T
    EGOSHIN, IN
    ORMANDZH.S
    OSIPENKO, BP
    SRNKA, D
    YURKOVSK.Y
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (03): : 45 - 46
  • [8] Performance of Indigenously Developed CsI(Tl)-Photodiode Detector for Gamma-ray Spectroscopy
    Singh, S. G.
    Singh, Arvind
    Topkar, Anita
    Gadkari, S. C.
    SOLID STATE PHYSICS: PROCEEDINGS OF THE 55TH DAE SOLID STATE PHYSICS SYMPOSIUM 2010, PTS A AND B, 2011, 1349 : 481 - +
  • [9] LOW-ENERGY GAMMA-RAY SOURCES
    WEST, R
    NUCLEONICS, 1953, 11 (02): : 20 - 23
  • [10] LOW-ENERGY GAMMA-RAY SPECTROSCOPY
    NYBAKKEN, TW
    VALI, V
    NUCLEAR INSTRUMENTS & METHODS, 1964, 26 (01): : 182 - 182