A chronoamperometric method to estimate changes in the membrane composition of ion-selective membranes

被引:39
作者
Pendley, BD
Gyurcsanyi, RE
Buck, RP
Lindner, E [1 ]
机构
[1] Univ Tennessee, Hlth Sci Ctr, Herff Coll Engn, Memphis, TN 38152 USA
[2] Univ Memphis, Joint Grad Program Biomed Engn, Memphis, TN 38152 USA
[3] Rhodes Coll, Dept Chem, Memphis, TN 38112 USA
[4] Hungarian Acad Sci, Res Grp Tech Analyt Chem, H-1111 Budapest, Hungary
[5] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
D O I
10.1021/ac010007e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chronoamperometric method is used to estimate changes in the membrane composition of mobile-site, ionophore-based membranes. The characteristic features of the chronoamperometric curves (initial current, slope, break time) of valinomycin-based, potassium-selective membranes loaded with potassium tetrakis(4-chlorophenyl)borate are correlated with the mobile-site and free ionophore concentration in the membrane. Limiting cases for strong and negligible ion pair formation are distinguished. Replicate measurements indicate a relative standard deviation in the calculated values less than 10%. The practical applicability of the method was tested with membranes incorporated into conventional ion-selective electrode bodies or cast onto microfabricated planar sensor structures.
引用
收藏
页码:4599 / 4606
页数:8
相关论文
共 25 条
  • [1] LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS
    AMMANN, D
    PRETSCH, E
    SIMON, W
    LINDNER, E
    BEZEGH, A
    PUNGOR, E
    [J]. ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) : 119 - 129
  • [2] PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES
    ARMSTRONG, RD
    HORVAI, G
    [J]. ELECTROCHIMICA ACTA, 1990, 35 (01) : 1 - 7
  • [3] MECHANISTIC ASPECTS OF THE K+ ION-SELECTIVE ELECTRODE BASED ON VALINOMYCIN PVC
    ARMSTRONG, RD
    [J]. ELECTROCHIMICA ACTA, 1987, 32 (11) : 1549 - 1552
  • [4] DONNAN EXCLUSION FAILURE IN LOW ANION SITE DENSITY MEMBRANES CONTAINING VALINOMYCIN
    BUCK, RP
    TOTH, K
    GRAF, E
    HORVAI, G
    PUNGOR, E
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 223 (1-2): : 51 - 66
  • [5] Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS
    Ceresa, A
    Bakker, E
    Hattendorf, B
    Günther, D
    Pretsch, E
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (02) : 343 - 351
  • [6] ION-SELECTIVE ELECTRODES USING AN IONOPHORE COVALENTLY ATTACHED TO CARBOXYLATED POLY(VINYL CHLORIDE)
    DAUNERT, S
    BACHAS, LG
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (14) : 1428 - 1431
  • [7] LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS
    DINTEN, O
    SPICHIGER, UE
    CHANIOTAKIS, N
    GEHRIG, P
    RUSTERHOLZ, B
    MORF, WE
    SIMON, W
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (06) : 596 - 603
  • [8] Producing "self-plasticizing" ion-selective membranes
    Heng, LY
    Hall, EAH
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (01) : 42 - 51
  • [9] ION-TRANSPORT PROPERTIES OF CYCLIC AND ACYCLIC NEUTRAL CARRIER-CONTAINING MEMBRANES
    IGLEHART, ML
    BUCK, RP
    [J]. TALANTA, 1989, 36 (1-2) : 89 - 98
  • [10] PLASTICIZED POLYVINYL-CHLORIDE) PROPERTIES AND CHARACTERISTICS OF VALINOMYCIN ELECTRODES - CURRENT TIME RESPONSES TO VOLTAGE STEPS
    IGLEHART, ML
    BUCK, RP
    HORVAI, G
    PUNGOR, E
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (10) : 1018 - 1022