Reliability Criteria for Liver Stiffness Measurements with Real-Time 2D Shear Wave Elastography in Different Clinical Scenarios of Chronic Liver Disease

被引:38
|
作者
Thiele, Maja [1 ,2 ,3 ]
Madsen, Bjorn Staehr [1 ,2 ,3 ]
Procopet, Bogdan [4 ]
Hansen, Janne Fuglsang [5 ]
Moller, Linda Marie Sevelsted [1 ,2 ]
Detlefsen, Soenke [6 ]
Berzigotti, Annalisa [7 ]
Krag, Aleksander [1 ,2 ]
机构
[1] Odense Univ Hosp, Dept Gastroenterol & Hepatol, Sdr Blvd 29, DK-5000 Odense, Denmark
[2] Syddansk Univ Det, Inst Clin Res, Sundhedsvidenskabelige Fak, Odense, Denmark
[3] Odense Univ Hosp, OPEN, Odense Patient Data Explorat Network, Odense, Denmark
[4] Iuliu Hatieganu Univ Med, Dept Gastroenterol & Hepatol, Cluj Napoca, Romania
[5] Odense Univ Hosp, Dept Infect Dis, Odense, Denmark
[6] Odense Univ Hosp, Dept Pathol, Odense, Denmark
[7] Univ Bern, Univ Clin Visceral Surg & Med UVCM, Inselspital, Bern, Switzerland
来源
ULTRASCHALL IN DER MEDIZIN | 2017年 / 38卷 / 06期
关键词
elastography; liver; aixplorer; quality criteria; supersonic shear imaging; TRANSIENT ELASTOGRAPHY; PORTAL-HYPERTENSION; FIBROSIS; APPLICABILITY; PERFORMANCE; ACCURACY;
D O I
10.1055/s-0042-108431
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose Liver stiffness measurement by real-time 2-dimensional shear wave elastography (2D-SWE) lacks universal reliability criteria. We sought to assess whether previously published 2D-SWE reliability criteria for portal hypertension were applicable for the evaluation of liver fibrosis and cirrhosis, and to look for criteria that minimize the risk of misclassification in this setting. Materials and Methods In a biopsy-controlled diagnostic study, we obtained five 2D-SWE measurements of optimal image quality. Correctly classified cases of fibrosis and cirrhosis were compared to misclassified cases. We compared reliability predictors (standard deviation (SD), SD/mean, size of region of interest (ROI) and difference between a single measurement and the patient's median) with those obtained in a prior study on clinically significant portal hypertension. Results We obtained 678 2D-SWE measurements from 142 patients. Overall, the variability in liver stiffness within single 2D-SWE measurements was low (SD = 1.1 +/- 1.5kPa; SD/ mean=12 +/- 9%). Intra-observer analysis showed almost perfect concordance (intraclass correlation coefficient = 0.95; 95 % CI 0.94-0.96; average difference from median = 0.4 +/- 0.9kPa). For the diagnosis of cirrhosis, a smaller SD (optimally = 1.75 kPa) and larger ROI size (optimally = 18 mm) were associated with higher accuracy. Similarly, within the published cohort of patients assessed for portal hypertension, a low variability of measurements was associated with high reliability. Conclusion A high quality 2D-SWE elastogram ensures low variability and high reliability, regardless of indication. We recommend aiming for a combination of low standard deviation and large ROI.
引用
收藏
页码:648 / 654
页数:7
相关论文
共 50 条
  • [1] ABDOMINAL WALL THICKNESS AFFECTS LIVER STIFFNESS MEASUREMENTS BY 2-D SHEAR WAVE ELASTOGRAPHY IN PATIENTS WITH CHRONIC LIVER DISEASE
    Cho, Young Seo
    Lim, Sanghyeok
    Kim, Yongsoo
    Kim, Tae Yeob
    Jeong, Woo Kyoung
    Sohn, Joo Hyun
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (10) : 2697 - 2703
  • [2] Real-Time Shear Wave Elastography for Determining the Ideal Site of Liver Biopsy in Diffuse Liver Disease
    Patidar, Yashwant
    Singh, Jitender
    Chatterjee, Navojit
    Mukund, Amar
    Rastogi, Archana
    Kumar, Guresh
    Sharma, Manoj Kumar
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (01) : 44 - 53
  • [3] Point shear wave ultrasound elastography with Esaote compared to real-time 2D shear wave elastography with supersonic imagine for the quantification of liver stiffness
    Mulazzani L.
    Salvatore V.
    Ravaioli F.
    Allegretti G.
    Matassoni F.
    Granata R.
    Ferrarini A.
    Stefanescu H.
    Piscaglia F.
    Journal of Ultrasound, 2017, 20 (3) : 213 - 225
  • [4] Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
    Ferraioli, Giovanna
    Tinelli, Carmine
    Zicchetti, Mabel
    Above, Elisabetta
    Poma, Gianluigi
    Di Gregorio, Marta
    Filice, Carlo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3102 - 3106
  • [5] Point Shear Wave Elastography for Assessing Liver Stiffness in Chronic Liver Diseases of Different Etiologies Compared to Biopsy
    Saadi, Tarek
    Khoury, Johad
    Toukan, Widad
    Krimasky, Rimma
    Veitsman, Ella
    Baruch, Yaacov
    Gaitini, Diana
    Beck-Razi, Nira
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2021, 23 (04): : 223 - 228
  • [6] 2D shear wave elastography: measurement acquisition and reliability criteria in noninvasive assessment of liver fibrosis
    Chung, Maggie
    Baird, Grayson L.
    Weiss, Krista E.
    Beland, Michael D.
    ABDOMINAL RADIOLOGY, 2019, 44 (10) : 3285 - 3294
  • [7] Noninvasive Assessment of Liver Diseases using 2D Shear Wave Elastography
    Lupsor-Platon, Monica
    Badea, Radu
    Gersak, Mirela
    Maniu, Anca
    Rusu, Ioana
    Suciu, Alina
    Vicas, Cristian
    Stefanescu, Horia
    Urs, Radu
    Al Hajjar, Nadim
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2016, 25 (04) : 525 - 532
  • [8] Liver stiffness measurement reliability and main determinants of point shear-wave elastography in patients with chronic liver disease
    Fraquelli, M.
    Baccarin, A.
    Casazza, G.
    Conti, C. B.
    Giunta, M.
    Massironi, S.
    Invernizzi, F.
    Donato, M. F.
    Maggioni, M.
    Aghemo, A.
    Conte, D.
    Colombo, M.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2016, 44 (04) : 356 - 365
  • [9] Shear Wave Elastography for Liver Stiffness Measurement in Clinical Sonographic Examinations Evaluation of Intraobserver Reproducibility, Technical Failure, and Unreliable Stiffness Measurements
    Yoon, Jeong Hee
    Lee, Jeong Min
    Han, Joon Koo
    Choi, Byung Ihn
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (03) : 437 - 447
  • [10] Liver Stiffness Measurements by 2D Shear-Wave Elastography: Effect of Steatosis on Fibrosis Evaluation
    Kumada, Takashi
    Toyoda, Hidenori
    Yasuda, Satoshi
    Ogawa, Sadanobu
    Gotoh, Tatsuya
    Ito, Takanori
    Tada, Toshifumi
    Tanaka, Junko
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) : 604 - 612