Assessment of mini-implant displacement using cone beam computed tomography

被引:26
作者
Alves, Matheus, Jr. [1 ]
Baratieri, Carolina [1 ]
Nojima, Lincoln Issamu [1 ]
机构
[1] Univ Fed Rio de Janeiro, Fac Dent, Dept Orthodont, Rio De Janeiro, Brazil
关键词
CBCT; mini-implant; stability; orthodontics; ORTHODONTIC ANCHORAGE; PROJECTION ERRORS; POSTERIOR TEETH; STABILITY; MINISCREWS; INTRUSION; CEPHALOMETRY; EXTRACTION; APPLIANCES; MAXILLARY;
D O I
10.1111/j.1600-0501.2010.02092.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess, through cone beam computed tomography (CBCT), the mini-implants' stability and behaviour when submitted to orthodontic force during upper molars' intrusion. Material and methods: Forty-one mini-implants were divided into two groups: 30 in the buccal and palatal mini-implants group (BPMI), inserted into buccal and palatal sides, and 11 in the midpalatal mini-implants group (MPMI), inserted into midpalatal suture. One day after insertion, a 200 gf was applied on the mini-implants during a 5-month period. CBCT was performed twice: before force application (CBCT 1) and 5 months later (CBCT 2). For mini-implant displacement assessment, the distance of mini-implants' head (HMI) and tail (TMI) to coronal, sagittal and axial planes was measured at CBCT 1 and 2. Results: For the BPMI group, the displacement rate was statistically significant (P<0.05) in all three dimensions for both the head and the tail. For the MPMI group, the displacement rate was statistically significant (P<0.05) only in the antero-posterior (head and tail) and vertical (head) dimensions. Conclusions: Buccal, palatal and midpalatal mini-implants showed some displacement (mean value <= 0.78) when submitted to force, although they are aimed to provide stable skeletal anchorage.
引用
收藏
页码:1151 / 1156
页数:6
相关论文
共 38 条
  • [1] THE EFFECT OF PROJECTION ERRORS ON CEPHALOMETRIC LENGTH MEASUREMENTS
    AHLQVIST, J
    ELIASSON, S
    WELANDER, U
    [J]. EUROPEAN JOURNAL OF ORTHODONTICS, 1986, 8 (03) : 141 - 148
  • [2] AHLQVIST J, 1988, EUR J ORTHODONT, V10, P353
  • [3] Implant design and intraosseous stability of immediately placed implants: a human cadaver study
    Akkocaoglu, M
    Uysal, S
    Tekdemir, I
    Akca, K
    Cehreli, MC
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (02) : 202 - 209
  • [4] Bae Seong-Min, 2002, J Clin Orthod, V36, P298
  • [5] Linear Accuracy of Cone Beam CT Derived 3D Images
    Brown, April A.
    Scarfe, William C.
    Scheetz, James P.
    Silveira, Anibal M.
    Farman, Allan G.
    [J]. ANGLE ORTHODONTIST, 2009, 79 (01) : 150 - 157
  • [6] Head Orientation in CBCT-generated Cephalograms
    Cevidanes, Lucia
    Oliveira, Ana E. F.
    Motta, Alexandre
    Phillips, Ceib
    Burke, Brandon
    Tyndall, Donald
    [J]. ANGLE ORTHODONTIST, 2009, 79 (05) : 971 - 977
  • [7] Chen YJ, 2000, ANGLE ORTHOD, V70, P387
  • [8] Cheng SJ, 2004, INT J ORAL MAX IMPL, V19, P100
  • [9] Dula K, 2001, INT J ORAL MAX IMPL, V16, P80
  • [10] Loss of anchorage of miniscrews: A 3-dimensional assessment
    El-Beialy, Amr Ragab
    Abou-El-Ezz, Amr Mohamed
    Attia, Khaled Hazem
    El-Bialy, Ahmad Mohamed
    Mostafa, Yehya Ahmed
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (05) : 700 - 707