Detection and correction of distorted current transformer current using wavelet transform and artificial intelligence

被引:44
作者
Hong, Y. -Y. [1 ]
Chang-Chian, P. -C. [1 ]
机构
[1] Chung Yuan Christian Univ, Dept Elect Engn, Chungli 320, Taiwan
关键词
D O I
10.1049/iet-gtd:20070383
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Secondary current in a current transformer (CT) will become distorted if the CT becomes saturated because of a large primary current and a DC component. This distorted current may leads to a malfunction in the protective relay because it receives a smaller rms current during the period of the fault occurrence. Therefore detection and correction of the distorted current caused by the saturated CT is essential. The application of wavelet transform used to detect the occurrence time of the fault and identify all saturation periods is described. Two features of the fault current were extracted. Fuzzy-c-means was used to partition all possible currents into nine clusters according to their features. Nine multi-layer feed-forward neural networks (MFNNs) were trained individually with the corresponding smaller fault current data sets to obtain corrected secondary currents at the initial stage. Takagi-Sugeno-Kang fuzzy rules were then used to integrate all the MFNN output currents into the final corrected secondary current. The proposed method was verified by SIMULINK/Visual C and was also implemented in a field programmable gate array (FPGA, Altera Stratix EP1S25F780C5 development board). The test results show the online applicability of the proposed method.
引用
收藏
页码:566 / 575
页数:10
相关论文
共 27 条
[1]   FCM - THE FUZZY C-MEANS CLUSTERING-ALGORITHM [J].
BEZDEK, JC ;
EHRLICH, R ;
FULL, W .
COMPUTERS & GEOSCIENCES, 1984, 10 (2-3) :191-203
[2]  
Burrus C.S., 1998, introduction to Wavelets and Wavelet Transforms-A Primer
[3]   Proposed wavelet-neurofuzzy combined system for power quality violations detection and diagnosis [J].
Elmitwally, A ;
Farghal, S ;
Kandil, M ;
Abdelkader, A ;
Elkateb, M .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2001, 148 (01) :15-20
[4]   An impedance-based CT saturation detection algorithm for bus-bar differential protection [J].
Fernández, C .
IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (04) :468-472
[5]   Determination of network configuration considering multiobjective in distribution systems using genetic algorithms [J].
Hong, YY ;
Ho, SY .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) :1062-1069
[6]   Switching detection/classification using discrete wavelet transform and self-organizing mapping network [J].
Hong, YY ;
Wang, CW .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :1662-1668
[7]   Compensation of the distortion in the secondary current caused by saturation and remanence in a CT [J].
Kang, YC ;
Lim, UJ ;
Kang, SH ;
Crossley, PA .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) :1642-1649
[8]   Design and evaluation of an algorithm for detecting current transformer saturation [J].
Kang, YC ;
Ok, SH ;
Kang, SH ;
Crossley, PA .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2004, 151 (01) :27-35
[9]   A CT saturation detection algorithm [J].
Kang, YC ;
Ok, SH ;
Kang, SH .
IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (01) :78-85
[10]   Development and hardware implementation of a compensating algorithm for the secondary current of current transformers [J].
Kang, YC ;
Kang, SH ;
Park, JK ;
Johns, AT ;
Aggarwal, RK .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1996, 143 (01) :41-49