Using edge enhancement to identify subtle findings on soft-copy neonatal chest radiographs

被引:9
作者
Goo, HW
Kim, HJ
Song, KS
Kim, EAR
Kim, KS
Yoon, CH
Pi, SY
机构
[1] Univ Ulsan, Dept Radiol, Asan Med Ctr, Coll Med, Seoul 138736, South Korea
[2] Univ Ulsan, Dept Neonatol, Asan Med Ctr, Coll Med, Seoul 138736, South Korea
关键词
D O I
10.2214/ajr.177.2.1770437
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE, The purpose of this study was to evaluate whether edge enhancement could improve the visibility of subtle findings on soft copies of neonatal chest radiographs. MATERIALS AND METHODS. Two radiologists reviewed 82 soft-copy neonatal chest radiographs before and after the application of edge enhancement on our picture archiving and communication system (PACS). The visibility of a pneumothorax (n = 22), central venous catheter (n = 32), umbilical arterial catheter (n = 36), endotracheal tube (n = 40), and normal anatomic structures (the minor fissure, anterior segmental bronchus of the right upper lobe, and aortic arch, n = 57) was evaluated. Six of 22 soft-copy images depicting a pneumothorax were excluded from the evaluation of image quality either because of the large size of the pneumothorax itself (n = 7) or because of the lack of confirmatory evidence that would have been provided by an additional lateral decubitus (n = 6) or cross-table lateral radiograph (n = 3). image quality was evaluated by visual grading analysis. RESULTS. The visibility of a pneumothorax (p < 0.01), vascular catheters (p < 0.001), the minor fissure (p < 0.001), and the anterior segmental bronchus of the right upper lobe (p < 0.001) improved significantly after applying edge enhancement to soft copies of neonatal chest radiographs, whereas the visibility of the aortic arch did not improve. Evaluations of the improvements in the visibility of the endotracheal tube were inconsistent. CONCLUSION. Application of edge enhancement to soft copies of neonatal chest radiographs helps radiologists to identify small pneumothoraces, vascular catheters, and delicate normal structures, thereby improving the detection of subtle chest findings in the neonatal intensive care unit.
引用
收藏
页码:437 / 440
页数:4
相关论文
共 12 条
  • [1] Finding-specific display presets for computed radiography soft-copy reading
    Andriole, KP
    Gould, RG
    Webb, WR
    [J]. JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) : 3 - 5
  • [2] COMPARISON OF A PACS WORKSTATION WITH CONVENTIONAL FILM FOR INTERPRETATION OF NEONATAL EXAMINATIONS - A PAIRED COMPARISON STUDY
    FRANKEN, EA
    SMITH, WL
    BERBAUM, KS
    KAO, SCS
    SATO, Y
    [J]. PEDIATRIC RADIOLOGY, 1991, 21 (05) : 336 - 340
  • [3] Giger M, 1996, RADIOL CLIN N AM, V34, P565
  • [4] PNEUMOTHORAX AND OTHER LUNG-DISEASES - EFFECT OF ALTERED RESOLUTION AND EDGE ENHANCEMENT ON DIAGNOSIS WITH DIGITIZED RADIOGRAPHS
    GOODMAN, LR
    FOLEY, WD
    WILSON, CR
    TIKOFSKY, RS
    HOFFMANN, RG
    [J]. RADIOLOGY, 1988, 167 (01) : 83 - 88
  • [5] DIGITAL AND CONVENTIONAL CHEST IMAGES - OBSERVER PERFORMANCE WITH FILM DIGITAL RADIOGRAPHY SYSTEM
    GOODMAN, LR
    FOLEY, WD
    WILSON, CR
    RIMM, AA
    LAWSON, TL
    [J]. RADIOLOGY, 1986, 158 (01) : 27 - 33
  • [6] Digital chest radiography - Optimizing image processing parameters for the visibility of chest lesions and anatomy
    Kheddache, S
    Denbratt, L
    Angelhed, JE
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1996, 22 (03) : 241 - 245
  • [7] Influence of image processing on chest radiograph interpretation and decision changes
    Krupinski, EA
    Evanoff, M
    Ovitt, T
    Standen, JR
    Chu, TX
    Johnson, J
    [J]. ACADEMIC RADIOLOGY, 1998, 5 (02) : 79 - 85
  • [8] SPATIAL-RESOLUTION REQUIREMENTS FOR DIGITAL CHEST RADIOGRAPHS - AN ROC STUDY OF OBSERVER PERFORMANCE IN SELECTED CASES
    LAMS, PM
    COCKLIN, ML
    [J]. RADIOLOGY, 1986, 158 (01) : 11 - 19
  • [9] DIGITAL RADIOGRAPHY OF SUBTLE PULMONARY ABNORMALITIES - AN ROC STUDY OF THE EFFECT OF PIXEL SIZE ON OBSERVER PERFORMANCE
    MACMAHON, H
    VYBORNY, CJ
    METZ, CE
    DOI, K
    SABETI, V
    SOLOMON, SL
    [J]. RADIOLOGY, 1986, 158 (01) : 21 - 26
  • [10] Observer performance in the localization of tubes and catheters on digital chest images: The role of expertise and image enhancement
    Nodine, CF
    Liu, H
    Miller, WT
    Kundel, HL