Atomic model validation using the CCP-EM sottware suite

被引:8
作者
Joseph, Agnel Praveen [1 ]
Olek, Mateusz [2 ,3 ]
Malhotra, Sony [1 ]
Zhang, Peijun [3 ]
Cowtan, Kevin [2 ]
Burnley, Tom [1 ]
Winn, Martyn D. [1 ]
机构
[1] Sci & Technol Facil Council, Sci Comp Dept, Didcot, Oxon, England
[2] Univ York, Dept Chem, York, N Yorkshire, England
[3] Electron BioImaging Ctr, Rutherford Appleton Lab, Diamond Light Source, Didcot, Oxon, England
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2022年 / 78卷
基金
英国惠康基金; 英国生物技术与生命科学研究理事会;
关键词
cryo-EM; model validation; CCP-EM; SARS-CoV-2; model geometry; PROTEIN SECONDARY STRUCTURE; ELECTRON-MICROSCOPY DATA; REFINEMENT; MAPS; RECOGNITION; QUALITY; ERRORS; TOOLS;
D O I
10.1107/S205979832101278X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recently, there has been a dramatic improvement in the quality and quantity of data derived using cryogenic electron microscopy (cryo-EM). This is also associated with a large increase in the number of atomic models built. Although the best resolutions that are achievable are improving, often the local resolution is variable, and a significant majority of data are still resolved at resolutions worse than 3 angstrom. Model building and refinement is often challenging at these resolutions, and hence atomic model validation becomes even more crucial to identify less reliable regions of the model. Here, a graphical user interface for atomic model validation, implemented in the CCP-EM software suite, is presented. It is aimed to develop this into a platform where users can access multiple complementary validation metrics that work across a range of resolutions and obtain a summary of evaluations. Based on the validation estimates from atomic models associated with cryo-EM structures from SARS-CoV-2, it was observed that models typically favor adopting the most common conformations over fitting the observations when compared with the model agreement with data. At low resolutions, the stereochemical quality may be favored over data fit, but care should be taken to ensure that the model agrees with the data in terms of resolvable features. It is demonstrated that further re-refinement can lead to improvement of the agreement with data without the loss of geometric quality. This also highlights the need for improved resolution-dependent weight optimization in model refinement and an effective test for overfitting that would help to guide the refinement process.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 50 条
  • [1] Recent developments in the CCP-EM software suite
    Burnley, Tom
    Palmer, Colin M.
    Winn, Martyn
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2017, 73 : 469 - 477
  • [2] Overview and applications of map and model validation tools in the CCP-EM software suite
    Joseph, Agnel Praveen
    Malhotra, Sony
    Burnley, Tom
    Winn, Martyn D.
    FARADAY DISCUSSIONS, 2022, 240 (00) : 196 - 209
  • [3] Current approaches for automated model building into cryo-EM maps using Buccaneer with CCP-EM
    Hoh, Soon Wen
    Burnley, Tom
    Cowtan, Kevin
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2020, 76 : 531 - 541
  • [4] Current approaches for the fitting and refinement of atomic models into cryo-EM maps using CCP-EM
    Nicholls, Robert A.
    Tykac, Michal
    Kovalevskiy, Oleg
    Murshudov, Garib N.
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2018, 74 : 492 - 505
  • [5] Proceedings of the third CCP-EM Spring Symposium
    Burnley, Tom
    da Fonseca, Paula
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2018, 74 : 490 - 491
  • [6] Introducing the Proceedings of the CCP-EM Spring Symposium
    Burnley, Tom
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2017, 73 : 467 - 468
  • [7] Cryo-EM Map-Based Model Validation Using the False Discovery Rate Approach
    Olek, Mateusz
    Joseph, Agnel Praveen
    FRONTIERS IN MOLECULAR BIOSCIENCES, 2021, 8
  • [8] Cryo-EM model validation using independent map reconstructions
    DiMaio, Frank
    Zhang, Junjie
    Chiu, Wah
    Baker, David
    PROTEIN SCIENCE, 2013, 22 (06) : 865 - 868
  • [9] Using a partial atomic model from medium-resolution cryo-EM to solve a large crystal structure
    Fabrega-Ferrer, Montserrat
    Cuervo, Ana
    Fernandez, Francisco J.
    Machon, Cristina
    Perez-Luque, Rosa
    Pous, Joan
    Vega, M. Cristina
    Carrascosa, Jose L.
    Coll, Miquel
    ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2021, 77 : 11 - 18
  • [10] Cryo-EM model validation recommendations based on outcomes of the 2019 EMDataResource challenge
    Lawson, Catherine L.
    Kryshtafovych, Andriy
    Adams, Paul D.
    Afonine, Pavel, V
    Baker, Matthew L.
    Barad, Benjamin A.
    Bond, Paul
    Burnley, Tom
    Cao, Renzhi
    Cheng, Jianlin
    Chojnowski, Grzegorz
    Cowtan, Kevin
    Dill, Ken A.
    DiMaio, Frank
    Farrell, Daniel P.
    Fraser, James S.
    Herzik, Mark A., Jr.
    Hoh, Soon Wen
    Hou, Jie
    Hung, Li-Wei
    Igaev, Maxim
    Joseph, Agnel P.
    Kihara, Daisuke
    Kumar, Dilip
    Mittal, Sumit
    Monastyrskyy, Bohdan
    Olek, Mateusz
    Palmer, Colin M.
    Patwardhan, Ardan
    Perez, Alberto
    Pfab, Jonas
    Pintilie, Grigore D.
    Richardson, Jane S.
    Rosenthal, Peter B.
    Sarkar, Daipayan
    Schafer, Luisa U.
    Schmid, Michael F.
    Schroder, Gunnar F.
    Shekhar, Mrinal
    Si, Dong
    Singharoy, Abishek
    Terashi, Genki
    Terwilliger, Thomas C.
    Vaiana, Andrea
    Wang, Liguo
    Wang, Zhe
    Wankowicz, Stephanie A.
    Williams, Christopher J.
    Winn, Martyn
    Wu, Tianqi
    NATURE METHODS, 2021, 18 (02) : 156 - +