Development and analytic validation of an electron ionization gas chromatography/mass spectrometry (EI-GC/MS) method for the measurement of 3-bromotyrosine in canine serum

被引:6
作者
Sattasathuchana, Panpicha [1 ,2 ]
Berghoff, Nora [1 ]
Grutzner, Niels [1 ]
Thengchaisri, Naris [2 ]
Rangachari, Venkat R. [1 ]
Suchodolski, Jan S. [1 ]
Steiner, Jorg M. [1 ]
机构
[1] Texas A&M Univ, Coll Vet Med & Biomed Sci, Dept Small Anim Clin Sci, Gastrointestinal Lab, College Stn, TX USA
[2] Kasetsart Univ, Dept Compan Anim Clin Sci, Fac Vet Med, Bangkok, Thailand
关键词
3-bromotyrosine; canine; eosinophil activation; eosinophil peroxidase; serum; HEPATIC NEUROENDOCRINE CARCINOMA; CATS;
D O I
10.1111/vcp.12373
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Background: The activation of eosinophils causes the release of eosinophil peroxidase and subsequent production of 3-bromotyrosine (3-BrY), a stable byproduct. In people, 3-BrY is used as a biomarker for eosinophil activation. The method for measuring 3-BrY concentrations in biologic samples from dogs has not previously been described. Objectives: The objective of this study was to develop and analytically validate an electron ionization gas chromatography/mass spectrometry (EI-GC/MS) method for the measurement of 3-BrY in canine serum samples. Methods: Pooled canine serum samples were utilized to validate the assay. Serum samples from healthy control dogs (n = 41) were used to evaluate 3-BrY concentrations and establish a reference interval. Results: The analytic validation revealed that the limit of blank and limit of detection were 0.33 and 0.63 mu mol/L, respectively. The coefficients of variation for precision and reproducibility for 3-BrY were < 13.9% and < 11.0%, respectively. The means +/- SD of observed-to-expected ratios for linearity and accuracy were 109.6 +/- 17.2% and 98.7 +/- 11.3%, respectively. The reference interval was determined as <= 1.12 mu mol/L (median [range]: <= 0.63 mu mol/L [<= 0.63-1.13]). Conclusions: The EI-GC/MS assay described here for the measurement of 3-BrY in canine serum samples was precise, reproducible, linear, and accurate. Further studies are underway to determine the diagnostic utilities in canine patients with eosinophilic diseases.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 1 条
  • [1] Development and Validation of an Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Quantitation of Total 3,3',5-triiodo-L-Thyronine and 3,3',5,5'-tetraiodo-L-Thyronine in Rodent Serum
    Waidyanatha, Suramya
    Fletcher, Brenda L.
    Fernando, Reshan A.
    Cora, Michelle C.
    Silinski, Melanie A. Rehder
    ANALYTICAL LETTERS, 2022, 55 (05) : 796 - 811