Validation of four-dimensional computed tomography without external reference respiratory signals for radiation treatment planning of lung tumors

被引:2
作者
Doi, Yasuhiro [1 ]
Shimohigashi, Yoshinobu [1 ]
Kai, Yudai [1 ]
Maruyama, Masato [1 ]
Toya, Ryo [2 ]
机构
[1] Kumamoto Univ Hosp, Dept Radiol Technol, Chuo Ku, 1-1-1 Honjo, Kumamoto 8608556, Japan
[2] Kumamoto Univ Hosp, Dept Radiat Oncol, Kumamoto, Japan
关键词
four-dimensional (4D); computed tomography (CT); deviceless 4D CT; Multicell 4D phantom; radiation treatment planning; lung tumor; TARGET VOLUMES; RADIOTHERAPY;
D O I
10.1088/2057-1976/ac8555
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Deviceless four-dimensional (4D) computed tomography (CT) allows the acquisition of respiratory signals from six features without requiring an external device for cine CT processing. This method has been recently introduced in radiation treatment planning of lung tumors. To validate deviceless 4D CT, it must be compared with conventional 4D CT, which requires an external monitoring device. We compared the two methods using a multicell 4D phantom that simulates patient's movement during respiration regarding the target volume (TV), target position (TP), and internal TV for lung tumor radiation therapy. We retrospectively obtained images of 10 patients who underwent radiation treatment planning of lung tumors and compared the two methods, as in the phantom study. For the phantom study, the mean TV, root mean square errors of the TP, and mean internal TV differences between the two methods ranged from -4.5% to 1.2%, 0.7 to 2.6 mm, and -1.1% to 3.4%, respectively. The corresponding results of the clinical study ranged from -1.5% to 14.9%, 0.1 to 5.9 mm, and -9.7% to 10.1%, respectively. The results of deviceless 4D CT for the clinical study were consistent with those of conventional 4D CT, except for target movements with high excursions. Therefore, deviceless 4D CT can be an alternative to conventional 4D CT for radiation treatment planning of lung tumors.
引用
收藏
页数:7
相关论文
共 16 条
[1]  
[Anonymous], SMART DEVICELESS 4D
[2]   Investigation of sliced body volume (SBV) as respiratory surrogate [J].
Cai, Jing ;
Chang, Zheng ;
O'Daniel, Jennifer ;
Yoo, Sua ;
Ge, Hong ;
Kelsey, Christopher ;
Yin, Fang-Fang .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01) :71-80
[3]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[4]   Target volume and motion position evaluation of four-dimensional cone-beam CT: comparison with 4D-CT using dynamic thorax phantom [J].
Doi, Yasuhiro ;
Shimohigashi, Yoshinobu ;
Yotsuji, Yohei ;
Maruyama, Masato ;
Kai, Yudai ;
Toya, Ryo .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03)
[5]   Investigation of Internal Target Volumes Using Device and Deviceless Four-dimensional Respiratory Monitoring Systems for Moving Targets in Four-dimensional Computed Tomography Acquisition [J].
Holla, Raghavendra ;
Khanna, D. ;
Barsing, Shubhangi ;
Pillai, Bhaskaran K. ;
Ganesh, Tharmarnadar .
JOURNAL OF MEDICAL PHYSICS, 2019, 44 (02) :77-83
[6]   Advances in 4D medical imaging and 4D radiation therapy [J].
Li, Guang ;
Citrin, Deborah ;
Camphausen, Kevin ;
Mueller, Boris ;
Burman, Chandra ;
Mychalczak, Borys ;
Miller, Robert W. ;
Song, Yulin .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (01) :67-81
[7]   4D CT sorting based on patient internal anatomy [J].
Li, Ruijiang ;
Lewis, John H. ;
Cervino, Laura I. ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15) :4821-4833
[8]   Target volume and artifact evaluation of a new data-driven 4D CT [J].
Martin, Rachael ;
Pan, Tinsu .
PRACTICAL RADIATION ONCOLOGY, 2017, 7 (05) :E345-E354
[9]   Basic evaluation of a novel 4D target and human body phantom [J].
Matsumoto, Y. ;
Kabuki, S. ;
Sugawara, A. ;
Kitahara, T. ;
Akiba, T. ;
Fujita, Y. ;
Kawamata, I ;
Yamada, K. ;
Amino, K. ;
Sasaki, Y. ;
Nishida, M. ;
Murakami, K. ;
Sugahara, K. ;
Saito, N. ;
Kunieda, E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (14)
[10]   Use of Maximum Intensity Projections (MIPs) for Target Outlining in 4DCT Radiotherapy Planning [J].
Muirhead, Rebecca ;
McNee, Stuart G. ;
Featherstone, Carrie ;
Moore, Karen ;
Muscat, Sarah .
JOURNAL OF THORACIC ONCOLOGY, 2008, 3 (12) :1433-1438