Rotational panoramic versus Intraoral rectangular radiographs for evaluation of peri-implant bone loss in the anterior atrophic mandible

被引:0
|
作者
Zechner, W
Watzak, G
Gahleitner, A
Busenlechner, D
Tepper, G
Watzek, G
机构
[1] Univ Vienna, Sch Dent, Dept Oral Surg, A-1090 Vienna, Austria
[2] Ludwig Boltzmann Inst Oral Implantol, Vienna, Austria
[3] Univ Vienna, Sch Dent, Radiodiagnost Unit, A-1090 Vienna, Austria
[4] Univ Vienna, Sch Dent, Dept Oral Surg, A-1090 Vienna, Austria
[5] Ludwig Boltzmann Inst Oral Implantol, Vienna, Austria
关键词
atrophy; dental implants; intraoral radiography; mandible; panoramic radiography;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: In patients with atrophic mandibles, elevation of the floor of the mouth often prevents intraoral rectangular radiography for longitudinal follow-up studies, while extraoral techniques such as panoramic radiographs tend to produce distorted views of the interforaminal region. In this study, intraoral rectangular radiographs and panoramic radiographs were compared for their accuracy in evaluating peri-implant bone loss. Materials and Methods: In a recall program, 22 patients with 88 screw-type implants (44 MKII and 44 Frios) were followed. Interforaminal marginal bone loss was evaluated by extraoral orthopantomograms and by intraoral rectangular radiographs. In addition, pocket depth, Periotest readings, and bleeding on probing were recorded. For statistical analysis, the Spearman coefficient of correlation was used. The effects on bone loss and clinical variables were computed with a mixed model and the Bland and Altman method. Results: Computed as least square means, the mean difference between panoramic radiographs (2.4 +/- 0.2 mm for MKII implants and 1.6 +/- 0.2 mm for Frios implants) and intraoral radiographs (2.6 +/- 0.2 mm and 1.4 +/- 0.2 mm, respectively) was 0.2 mm (range, 0.1 to 0.8 mm). Discussion: In this study, the 2 imaging techniques were comparable clinically in terms of the precision with which they could be used to measure marginal bone loss. Conclusion: For highly atrophic mandibles with unfavorable imaging conditions, rotational panoramic radiographs can be a useful alternative to intraoral small-format radiographs for evaluating periimplant bone loss.
引用
收藏
页码:873 / 878
页数:6
相关论文
共 15 条
  • [1] Fractal analysis for the assessment of trabecular peri-implant alveolar bone using panoramic radiographs
    Mert Zeytinoğlu
    Betül İlhan
    Nesrin Dündar
    Hayal Boyacioğlu
    Clinical Oral Investigations, 2015, 19 : 519 - 524
  • [2] Fractal analysis for the assessment of trabecular peri-implant alveolar bone using panoramic radiographs
    Zeytinoglu, Mert
    Ilhan, Betul
    Dundar, Nesrin
    Boyacioglu, Hayal
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (02) : 519 - 524
  • [3] Peri-implant bone loss around posterior mandible dental implants placed after distraction osteogenesis: Preliminary findings
    Polo, Wilson C. K.
    de Araujo, Ney Soares
    Lima, Ynara B. O.
    Joly, Julio Cesar
    Sendyk, Wilson R.
    Cury, Patricia R.
    JOURNAL OF PERIODONTOLOGY, 2007, 78 (02) : 204 - 208
  • [4] Influence of the Tube Angle on the Measurement Accuracy of Peri-Implant Bone Defects in Rectangular Intraoral X-ray Imaging
    Rugani, Petra
    Weingartner, Katharina
    Jakse, Norbert
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [5] Clinical evaluation of two dental implant macrostructures on peri-implant bone loss: a comparative, retrospective study
    Dagorne, Cecile
    Malet, Jacques
    Bizouard, Geoffray
    Mora, Francis
    Range, Helene
    Bouchard, Philippe
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (03) : 307 - 313
  • [6] Accuracy of peri-implant bone evaluation using cone beam CT, digital intra-oral radiographs and histology
    Ritter, L.
    Elger, M. C.
    Rothamel, D.
    Fienitz, T.
    Zinser, M.
    Schwarz, F.
    Zoeller, J. E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (06)
  • [7] Challenges in detecting various peri-implant bone defects on modified intraoral oblique radiographic projections: evaluation of an artificial mandibular model
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    ORAL RADIOLOGY, 2025, 41 (02) : 248 - 259
  • [8] Evaluation of peri-implant bone defects on cone-beam computed tomography and the diagnostic accuracy of detecting these defects on panoramic images
    Oshima, Takayuki
    Asaumi, Rieko
    Ogura, Shin
    Kawai, Taisuke
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 171 - 180
  • [9] Evaluation of Peri-Implant Crestal Bone Loss with Different Implant Systems, Primary Stability, Bone Density and Soft Tissue Thickness: A Retrospective Study
    Shenoy A.
    Rohinikumar S.
    Maiti S.
    Sivaswamy V.
    Rajaraman V.
    Journal of Long-Term Effects of Medical Implants, 2023, 33 (04) : 53 - 58
  • [10] Evaluation of Peri-Implant Marginal Bone Loss Using Modified Abutment Connections at Various Crestal Level Placements
    Veis, Alexander
    Parissis, Nikolaos
    Tsirlis, Anastasios
    Papadeli, Chrysa
    Marinis, Georgios
    Zogakis, Antonios
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2010, 30 (06) : 609 - 617