Characterization of H2RG IR detectors for the Euclid NISP instrument

被引:5
作者
Secroun, Aurelia [1 ]
Serra, Benoit [1 ]
Clemens, Jean-Claude [1 ]
Ealet, Anne [1 ]
Lagier, Philippe [1 ]
Legras, Romain [1 ]
Niclas, Matthieu [1 ]
Caillat, Laurence [1 ]
Gillard, William [1 ]
Tilquin, Andre [1 ]
Barbier, Remi [2 ]
Ferriol, Sylvain [2 ]
Kubik, Bogna [2 ]
Smadja, Gerard [2 ]
Prieto, Eric [3 ]
Masciazek, Thierry [3 ]
Sorensen, Anton Norup [4 ]
机构
[1] Aix Marseille Univ, CNRS, IN2P3, UMR 7346, Marseille, France
[2] Univ Lyon 1, CNRS, IN2P3, IPNL,UMR5822, Lyon, France
[3] Aix Marseille Univ, CNRS, LAM, UMR 7326, Marseille, France
[4] NBI, Copenhagen, Denmark
来源
HIGH ENERGY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY VII | 2016年 / 9915卷
关键词
Euclid; NISP; IR detectors; H2RG; spectroscopy; photometry;
D O I
10.1117/12.2232070
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Euclid, a major ESA mission for the study of dark energy, will offer a large survey of tens of millions of galaxies thanks to its Near-Infrared Spectro-Photometer. For it to be successful, the 16 Teledyne's 2.3 mu m cutoff 2048x2048 pixels IR HgCdTe detectors of the focal plane must show very high performances over more than 95% of pixels, in terms of median dark current, total noise, budget error on non-linearity after correction, residual dark due to latency effects and quantum efficiency. This will be verified through a thorough characterization of their performances, leading to the production of the pixel map calibration database for the Euclid mission. Characterization is challenging in many ways: each detector will have to be fully and accurately characterized in less than three weeks, with rather tight requirements: dark current at the 10(-3) e-/s level with 10% accuracy, relative Pixel Response map better than 1%, obtained with an illumination flatness better than 1%, measurements alternating dark and high level illumination taking care of latency impacts. Due to statistics needs, very long runs (24h without interrupts) of scripted measurements would be executed. Systematics of the test bench should be at the end the limiting factor of the parameter measurement accuracy. Test plan, facilities with functionalities developed for those specific purposes and associated performances will be described.
引用
收藏
页数:9
相关论文
共 3 条
  • [1] Laureijs R., 2011, TECH REP
  • [2] Euclid Near Infrared Spectro Photometer instrument concept and first test results at the end of phase B
    Maciaszek, Thierry
    Ealet, Anne
    Jahnke, Knud
    Prieto, Eric
    Barbier, Remi
    Mellier, Yannick
    Costille, Anne
    Ducret, Franck
    Fabron, Christophe
    Gimenez, Jean-Luc
    Grange, Robert
    Martin, Laurent
    Rossin, Christelle
    Pamplona, Tony
    Vola, Pascal
    Clemens, Jean Claude
    Smadja, Gerard
    Amiaux, Jerome
    Barriere, Jean Christophe
    Berthe, Michel
    De Rosa, Adriano
    Franceschi, Enrico
    Morgante, Gianluca
    Trifoglio, Massimo
    Valenziano, Luca
    Bonoli, Carlotta
    Bortoletto, Favio
    D'Alessandro, Maurizio
    Corcione, Leonardo
    Ligori, Sebastiano
    Garilli, Bianca
    Riva, Marco
    Grupp, Frank
    Vogel, Carolin
    Hormuth, Felix
    Seidel, Gregor
    Wachter, Stefanie
    Javier Diaz, Jose
    Granena, Ferran
    Padilla, Cristobal
    Toledo, Rafael
    Lilje, Per B.
    Solheim, Bjarte G. B.
    Toulouse-Aastrup, Corinne
    Andersen, Michael
    Holmes, Warren
    Israelsson, Ulf
    Seiffert, Michael
    Weber, Carissa
    Waczynski, Augustyn
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2014: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2014, 9143
  • [3] Serra B., 2015, P SOC PHOTO-OPT INS, V9602