Detection of Explosive Vapors: The Roles of Exciton and Molecular Diffusion in Real-Time Sensing

被引:15
作者
Ali, Mohammad A. [1 ]
Shoaee, Safa [1 ]
Fan, Shengqiang [1 ]
Burn, Paul L. [1 ]
Gentle, Ian R. [1 ]
Meredith, Paul [1 ]
Shaw, Paul E. [1 ]
机构
[1] Univ Queensland, Sch Math & Phys, Sch Chem & Mol Biosci, Ctr Organ Photon & Elect, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
conjugated polymers; explosives; fluorescence; sensors; time-resolved spectroscopy; POLYMER SENSORS; SOLID-STATE; FLUORESCENT; FILMS; TNT; CHEMOSENSORS; BINDING;
D O I
10.1002/cphc.201600767
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Time-resolved quartz crystal microbalance with in situ fluorescence measurements are used to monitor the sorption of the nitroaromatic (explosive) vapor, 2,4-dinitrotoluene (DNT) into a porous pentiptycene-containing poly(phenyleneethynylene) sensing film. Correlation of the nitroaromatic mass uptake with fluorescence quenching shows that the analyte diffusion follows the Case-II transport model, a film-swelling-limited process, in which a sharp diffusional front propagates at a constant velocity through the film. At a low vapor pressure of DNT of approximate to 16 ppb, the analyte concentration in the front is sufficiently high to give an average fluorophore-analyte separation of approximate to 1.5 nm. Hence, a long exciton diffusion length is not required for real-time sensing in the solid state. Rather the diffusion behavior of the analyte and the strength of the binding interaction between the analyte and the polymer play first-order roles in the fluorescence quenching process.
引用
收藏
页码:3350 / 3353
页数:4
相关论文
共 27 条
[1]  
Alfrey T., 1966, J POLYM SCI, V12, P249
[2]   Molecular versus exciton diffusion in fluorescence-based explosive vapour sensors [J].
Ali, M. A. ;
Geng, Y. ;
Cavaye, H. ;
Burn, P. L. ;
Gentle, I. R. ;
Meredith, P. ;
Shaw, P. E. .
CHEMICAL COMMUNICATIONS, 2015, 51 (98) :17406-17409
[3]   Diffusion of nitroaromatic vapours into fluorescent dendrimer films for explosives detection [J].
Ali, Mohammad A. ;
Chen, Simon S. Y. ;
Cavaye, Hamish ;
Smith, Arthur R. G. ;
Burn, Paul L. ;
Gentle, Ian R. ;
Meredith, Paul ;
Shaw, Paul E. .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 210 :550-557
[4]   Synthesis and properties of poly(phenylene ethynylene)s with pendant hexafluoro-2-propanol groups [J].
Amara, JP ;
Swager, TM .
MACROMOLECULES, 2005, 38 (22) :9091-9094
[5]   Solid State Dendrimer Sensors: Effect of Dendrimer Dimensionality on Detection and Sequestration of 2,4-Dinitrotoluene [J].
Cavaye, Hamish ;
Shaw, Paul E. ;
Smith, Arthur R. G. ;
Burn, Paul L. ;
Gentle, Ian R. ;
James, Michael ;
Lo, Shih-Chun ;
Meredith, Paul .
JOURNAL OF PHYSICAL CHEMISTRY C, 2011, 115 (37) :18366-18371
[6]   Solid-State Dendrimer Sensors: Probing the Diffusion of an Explosive Analogue Using Neutron Reflectometry [J].
Cavaye, Hamish ;
Smith, Arthur R. G. ;
James, Michael ;
Nelson, Andrew ;
Burn, Paul L. ;
Gentle, Ian R. ;
Lo, S-C ;
Meredith, Paul .
LANGMUIR, 2009, 25 (21) :12800-12805
[7]  
Crank J., 1975, The Mathematics of Diffusion, V2nd
[8]   Binding of TNT to amplifying fluorescent polymers: An ab initio and molecular dynamics study [J].
Enlow, Mark A. .
JOURNAL OF MOLECULAR GRAPHICS & MODELLING, 2012, 33 :12-18
[9]   Implementation of serial amplifying fluorescent polymer arrays for enhanced chemical vapor sensing of landmines [J].
Fisher, M ;
laGrone, M ;
Sikes, J .
DETECTION AND REMEDIATION TECHNOLOGIES FOR MINES AND MINELIKE TARGETS VIII, PTS 1 AND 2, 2003, 5089 :991-1000
[10]   DIFFUSION OF SMALL MOLECULES IN POLYMERS [J].
FRISCH, HL ;
STERN, SA .
CRC CRITICAL REVIEWS IN SOLID STATE AND MATERIALS SCIENCES, 1983, 11 (02) :123-187