Voltage-Rectified Current and Fluid Flow in Conical Nanopores

被引:148
|
作者
Lan, Wen-Jie [1 ]
Edwards, Martin A. [1 ]
Luo, Long [1 ]
Perera, Rukshan T. [1 ]
Wu, Xiaojian [2 ]
Martin, Charles R. [2 ]
White, Henry S. [1 ]
机构
[1] Univ Utah, Dept Chem, 315 South 1400 East, Salt Lake City, UT 84112 USA
[2] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
基金
美国国家科学基金会;
关键词
ION CURRENT RECTIFICATION; DIFFERENTIAL ELECTROLYTE RESISTANCE; ELECTROOSMOTIC FLOW; GLASS NANOPORES; TRANSPORT; MEMBRANES; NANOPIPETTES; DIODES;
D O I
10.1021/acs.accounts.6b00395
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
CONSPECTUS: Ion current rectification (ICR) refers to the asymmetric potential-dependent rate of the passage of solution ions through a nanopore, giving rise to electrical current voltage characteristics that mimic those of a solid-state electrical diode. Since the discovery of ICR in quartz nanopipettes two decades ago, synthetic nanopores and nanochannels of various geometries, fabricated in membranes and on wafers, have been extensively investigated to understand fundamental aspects of ion transport in highly confined geometries. It is now generally accepted that ICR requires an asymmetric electrical double layer within the nanopore, producing an accumulation or depletion of charge-carrying ions at opposite voltage polarities. Our research groups have recently explored how the voltage-dependent ion distributions and ICR within nanopores can induce novel nanoscale flow phenomena that have applications in understanding ionics in porous materials used in energy storage devices, chemical sensing, and low-cost electrical pumping of fluids. In this Account, we review our most recent investigations on this topic, based on experiments using conical nanopores (10-300 nm tip opening) fabricated in thin glass, mica, and polymer membranes. Measurable fluid flow in nanopores can be induced either using external pressure forces, electrically via electroosmotic forces, or by a combination of these two forces. We demonstrate that pressure-driven flow can greatly alter the electrical properties of nanopores and, vice versa, that the nonlinear electrical properties of conical nanopores can impart novel and useful flow phenomena. Electroosmotic flow (EOF), which depends on the magnitude of the ion fluxes within the double layer of the nanopore, is strongly coupled to the accumulation/depletion of ions. Thus, the same underlying cause of ICR also leads to EOF rectification, i.e., unequal flows occurring for the same voltage but opposite polarities. EOF rectification can be used to electrically pump fluids with very precise control across membranes containing conical pores via the application of a symmetric sinusoidal voltage. The combination of pressure and asymmetric EOF can also provide a means to generate new nanopore electrical behaviors, including negative differential resistance (NDR), in which the current through a conical pore decreases with increasing driving force (applied voltage), similar to solid-state tunnel diodes. NDR results from a positive feedback mechanism between the ion distributions and EOF, yielding a true bistability in both fluid flow and electrical current at a critical applied voltage. Nanopore-based NDR is extremely sensitive to the surface charge near the nanopore opening, suggesting possible applications in chemical sensing.
引用
收藏
页码:2605 / 2613
页数:9
相关论文
共 50 条
  • [1] Electroosmotic flow rectification in conical nanopores
    Laohakunakorn, Nadanai
    Keyser, Ulrich F.
    NANOTECHNOLOGY, 2015, 26 (27)
  • [2] Dynamic Response of Ionic Current in Conical Nanopores
    Liu, Zhe
    Ma, Long
    Zhang, Hongwen
    Zhuang, Jiakun
    Man, Jia
    Siwy, Zuzanna S.
    Qiu, Yinghua
    ACS APPLIED MATERIALS & INTERFACES, 2024, 16 (23) : 30496 - 30505
  • [3] Influence of Biofluids Rheological Behavior on Electroosmotic Flow and Ionic Current Rectification in Conical Nanopores
    Matin, Meisam Habibi
    Salimi, Salahedin
    Yaghoobi, Ali
    JOURNAL OF PHYSICAL CHEMISTRY C, 2016, 120 (50) : 28832 - 28843
  • [4] Modulation of Ionic Current Rectification in Ultrashort Conical Nanopores
    Ma, Long
    Li, Zhongwu
    Yuan, Zhishan
    Huang, Chuanzhen
    Siwy, Zuzanna S.
    Qiu, Yinghua
    ANALYTICAL CHEMISTRY, 2020, 92 (24) : 16188 - 16196
  • [5] Precipitation-Induced Voltage-Dependent Ion Current Fluctuations in Conical Nanopores
    Innes, Laura
    Powell, Matthew R.
    Vlassiouk, Ivan
    Martens, Craig
    Siwy, Zuzanna S.
    JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (18) : 8126 - 8134
  • [6] Impact of Polyelectrolyte Multilayers on the Ionic Current Rectification of Conical Nanopores
    Ma, Tianji
    Gaigalas, Paulius
    Lepoitevin, Mathilde
    Plikusiene, Ieva
    Bechelany, Mikhael
    Janot, Jean-Marc
    Balanzat, Emmanuel
    Balme, Sebastien
    LANGMUIR, 2018, 34 (11) : 3405 - 3412
  • [7] Pressure-Dependent Ion Current Rectification in Conical-Shaped Glass Nanopores
    Lan, Wen-Jie
    Holden, Deric A.
    White, Henry S.
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2011, 133 (34) : 13300 - 13303
  • [8] Active current gating in electrically biased conical nanopores
    Bearden, Samuel
    Simpanen, Erik
    Zhang, Guigen
    NANOTECHNOLOGY, 2015, 26 (18) : 1 - 11
  • [9] Reversing current rectification to improve DNA-sensing sensitivity in conical nanopores
    Cai, Xiu-Hong
    Cao, Shuo-Hui
    Cai, Sheng-Lin
    Wu, Yuan-Yi
    Aimal, Muhammad
    Li, Yao-Qun
    ELECTROPHORESIS, 2019, 40 (16-17) : 2098 - 2103
  • [10] Ionic current conduction at low voltage of track-etched double conical nanopores modified by surfactant CTAB
    Zhu, XiaoRui
    Wang, Lin
    Wang, CeMing
    Wang, YuGang
    JOURNAL OF POLYMER RESEARCH, 2020, 27 (11)