Characterization of the noise performance of the elastographic system is necessary to evaluate the accuracy and precision of the estimated strain. The elastographic system includes the ultrasonic scanner, the computer controlled compression device and the strain estimation algorithm. In this paper, we present a method of characterizing the elastographic system experimentally using a uniformly elastic homogenous tissue-mimicking phantom. The strain response of the elastographic system is evaluated by characterizing the accuracy and precision of the strain estimates for a large range of input strains. The experimental results obtained follow the theoretical predictions obtained using the Strain Filter (SF) concept for the cross-correlation based strain estimator. In this paper, we illustrate the application of the Experimental Strain Response (ESR) to characterize strain estimation at the focus of the transducer and the axis of symmetry of the phantom.
引用
收藏
页码:17 / 30
页数:14
相关论文
共 29 条
[1]   Reduction of signal decorrelation from mechanical compression of tissues by temporal stretching: Applications to elastography [J].
Alam, SK ;
Ophir, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (01) :95-105
[2]   An adaptive strain estimator for elastography [J].
Alam, SK ;
Ophir, J ;
Konofagou, EE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (02) :461-472
[3]  
BERTRAND M, 1989, P IEEE ULTR S, P859
[4]  
Cespedes E. I., 1993, THESIS U HOUSTON
[5]   Intravascular elasticity imaging using ultrasound: Feasibility studies in phantoms [J].
deKorte, CL ;
Cespedes, EI ;
vanderSteen, AFW ;
Lancee, CT .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (05) :735-746
[6]   Imaging of the elastic properties of tissue - A review [J].
Gao, L ;
Parker, KJ ;
Lerner, RM ;
Levinson, SF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (08) :959-977
[7]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[8]   Phantom materials for elastography [J].
Hall, TJ ;
Bilgen, M ;
Insana, MF ;
Krouskop, TA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1355-1365
[9]   Three-dimensional tissue motion and its effect on image noise in elastography [J].
Kallel, F ;
Ophir, J .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (06) :1286-1296
[10]   The nonstationary strain filter in elastography .2. Lateral and elevational decorrelation [J].
Kallel, F ;
Varghese, T ;
Ophir, J ;
Bilgen, M .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (09) :1357-1369