Dispersive liquid-liquid microextraction and preconcentration of thallium species in water samples by two ionic liquids applied as ion-pairing reagent and extractant phase

被引:51
作者
Escudero, Leticia B. [1 ]
Berton, Paula [1 ]
Martinis, Estefania M. [1 ]
Olsina, Roberto A. [2 ]
Wuilloud, Rodolfo G. [1 ,3 ]
机构
[1] LISAMEN CCT CONICET Mendoza, Analyt Chem Res & Dev Grp QUIANID, Mendoza, Argentina
[2] Univ Nacl San Luis, Fac Quim Bioquim & Farm, Dept Quim Analit, INQUISAL CONICET, San Luis, Argentina
[3] Univ Nacl Cuyo, Inst Ciencias Basicas, RA-5500 Mendoza, Argentina
关键词
Ionic liquid; 1-Hexyl-3-methylimidazolium hexafluorophosphate; Tetradecyl(trihexyl)phosphonium chloride; (CYPHOS (R) IL 101); Microextraction; Thallium; Speciation; ATOMIC-ABSORPTION-SPECTROMETRY; SPECIATION ANALYSIS; INJECTION; TOXICITY; SOLVENT;
D O I
10.1016/j.talanta.2011.09.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present work, a simple and highly sensitive analytical methodology for determination of Tl+ and Tl3+ species, based on the use of modern and non-volatile solvents, such as ionic liquids (ILs), was developed. Initially, Tl+ was complexed by iodide ion at pH 1 in diluted sulfuric acid solution. Then, tetradecyl(trihexyl)phosphonium chloride ionic liquid (CYPHOS (R) IL 101) was used as ion-pairing reagent and a dispersive liquid-liquid microextraction (DLLME) procedure was developed by dispersing 60 mg of 1-hexyl-3-methylimidazolium hexafluorophosphate [C(6)mim][PF6]with 500 mu L. of ethanol in the aqueous solution. After the microextraction procedure was finished, the final IL phase was solubilized in methanol and directly injected into the graphite furnace of an electrothermal atomic absorption spectrometer (ETAAS). An extraction efficiency of 77% and a sensitivity enhancement factor of 100 were obtained with only 5.00 mL of sample. The limit of detection (LOD) was 3.3 ng L-1 Tl while the relative standard deviation (RSD) was 5.3% (at 0.4 mu g L-1 Tl and n = 10), calculated from the peak height of absorbance signals. The method was finally applied to determine Tl species in tap and river water samples after separation of Tl3+ species. To the best of our knowledge, this work reports the first application of ILs for Tl extraction and separation in the analytical field. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:277 / 283
页数:7
相关论文
共 39 条
  • [1] Altundag H, 2009, FRESEN ENVIRON BULL, V18, P98
  • [2] Preconcentration Methods for Determination of Thallium in Natural Waters
    Arpadjan, Sonja
    Petrova, Pavleta
    Knutsson, Jesper
    [J]. EURASIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 3 (01): : 10 - 18
  • [3] Determination of thallium traces by ETAAS after on-line matrix separation and preconcentration in a flow injection system
    Asadoulahi, Taherah
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2007, 18 (07) : 1353 - 1359
  • [4] Determination of thallium in soils by flame atomic absorption spectrometry
    Asami, T
    Mizui, C
    Shimada, T
    Kubota, M
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 356 (05): : 348 - 351
  • [5] Cold-induced aggregation microextraction: A novel sample preparation technique based on ionic liquids
    Baghdadi, Majid
    Shemirani, Farzaneh
    [J]. ANALYTICA CHIMICA ACTA, 2008, 613 (01) : 56 - 63
  • [6] Highly selective ionic liquid-based microextraction method for sensitive trace cobalt determination in environmental and biological samples
    Berton, Paula
    Wuilloud, Rodolfo G.
    [J]. ANALYTICA CHIMICA ACTA, 2010, 662 (02) : 155 - 162
  • [7] Busev A.l., 1958, KHIM I KHIM TEKHNOL, V3, P486
  • [8] Preconcentration of thallium (I) by single drop microextraction with electrothermal atomic absorption spectroscopy detection using dicyclohexano-18-crown-6 as extractant system
    Chamsaz, Mahmoud
    Arbab-Zavar, Mohammad Hossien
    Darroudi, Abolfazl
    Salehi, Thiery
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 167 (1-3) : 597 - 601
  • [9] Sample preparation
    Chen, Yi
    Guo, Zhenpeng
    Wang, Xiaoyu
    Qiu, Changgui
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 191 - 219
  • [10] Determination of thallium in wine by electrothermal atomic absorption spectrometry after extraction preconcentration
    Cvetkovic, J
    Arpadjan, S
    Karadjova, I
    Stafilov, T
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (06) : 1101 - 1106