Detection and quantification of coronary atherosclerotic plaque by 64-slice multidetector CT: A systematic head-to-head comparison with intravascular ultrasound

被引:64
作者
Papadopoulou, Stella-Lida [1 ]
Neefjes, Lisan A. [1 ]
Schaap, Michiel [2 ,3 ]
Li, Hui-Ling [1 ]
Capuano, Ermanno
van der Giessen, Alina G. [1 ]
Schuurbiers, Johan C. H. [1 ]
Gijsen, Frank J. H. [1 ]
Dharampal, Anoeshka S. [1 ]
Nieman, Koen [1 ]
van Geuns, Robert Jan [1 ]
Mollet, Nico R. [1 ]
de Feyter, Pim J. [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Cardiol, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Radiol, Biomed Imaging Grp, NL-3000 CA Rotterdam, Netherlands
[3] Erasmus Univ, Med Ctr, Dept Med Informat, Biomed Imaging Grp, NL-3000 CA Rotterdam, Netherlands
关键词
Non-invasive imaging; Computed tomography; Intravascular ultrasound; Atherosclerotic plaque; SPIRAL COMPUTED-TOMOGRAPHY; INTRACORONARY ULTRASOUND; DIAGNOSTIC-ACCURACY; VIRTUAL HISTOLOGY; ANGIOGRAPHY;
D O I
10.1016/j.atherosclerosis.2011.07.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We evaluated the ability of 64-slice multidetector computed tomography (MDCT)-derived plaque parameters to detect and quantify coronary atherosclerosis, using intravascular ultrasound (IVUS) as the reference standard. Methods: In 32 patients, IVUS and 64-MDCT was performed. The MDCT and IVUS datasets of 44 coronary arteries were co-registered using a newly developed fusion technique and quantitative parameters were derived from both imaging modalities. The threshold of >0.5mm of maximum wall thickness was used to establish plaque presence on MDCT and IVUS. Results: We analyzed 1364 coregistered 1-mm coronary cross-sections and 255 segments of 5-mm length. Compared with IVUS, 64-MDCT enabled correct detection in 957 of 1109 cross-sections containing plaque (sensitivity 86%). In 180 of 255 cross-sections atherosclerosis was correctly excluded (specificity 71%). On the segmental level, MDCT detected 213 of 220 segments with any atherosclerotic plaque (sensitivity 96%), whereas the presence of any plaque was correctly ruled out in 28 of 32 segments (specificity 88%). Interobserver agreement for the detection of atherosclerotic cross-sections was moderate (Cohen's kappa coefficient K = 0.51), but excellent for the atherosclerotic segments (K = 1.0). Pearson's correlation coefficient for vessel plaque volumes measured by MDCT and IVUS was r = 0.91 (p < 0.001). Bland-Altman analysis showed a slight non-significant underestimation of any plaque volume by MDCT (p = 0.5), with a trend to underestimate noncalcified and overestimate mixed/calcified plaque volumes (p = 0.22 and p = 0.87 respectively). Conclusion: MDCT is able to detect and quantify atherosclerotic plaque. Further improvement in CT resolution is necessary for more reliable assessment of very small and distal coronary plaques. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:163 / 170
页数:8
相关论文
共 27 条
[1]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[2]   Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method [J].
de Winter, SA ;
Hamers, R ;
Degertekin, M ;
Tanabe, K ;
Lemos, PA ;
Serruys, PW ;
Roelandt, JRTC ;
Bruining, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 61 (01) :84-94
[3]  
DEY D, 1888, RADIOLOGY, V257, P516
[4]   A three-vessel virtual histology intravascular ultrasound analysis of frequency and distribution of thin-cap fibroatheromas in patients with acute coronary syndrome or stable angina pectoris [J].
Hong, Myeong-Ki ;
Mintz, Gary S. ;
Lee, Cheol Whan ;
Lee, Jeong-Woo ;
Park, Jae-Hyoung ;
Park, Duk-Woo ;
Lee, Seung-Whan ;
Kim, Young-Hak ;
Cheong, Sang-Sig ;
Kim, Jae-Joon ;
Park, Seong-Wook ;
Park, Seung-Jung .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (05) :568-572
[5]   Quantification and Characterization of Obstructive Coronary Plaques Using 64-Slice Computed Tomography: A Comparison With Intravascular Ultrasound [J].
Hur, Jin ;
Kim, Young Jin ;
Lee, Hye-Jeong ;
Nam, Ji Eun ;
Choe, Kyu Ok ;
Seo, Jae Seung ;
Choi, Dong-Hoon ;
Kim, Jung-Sun ;
Choi, Byoung Wook .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (02) :186-192
[6]   Accuracy of 64-slice computed tomography to classify and quantify plaque volumes in the proximal coronary system - A comparative study using intravascular ultrasound [J].
Leber, AW ;
Becker, A ;
Knez, A ;
von Ziegler, F ;
Sirol, M ;
Nikolaou, K ;
Ohnesorge, B ;
Fayad, ZA ;
Becker, CR ;
Reiser, M ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (03) :672-677
[7]   Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques - A comparative study with intracoronary ultrasound [J].
Leber, AW ;
Knez, A ;
Becker, A ;
Becker, C ;
von Ziegler, F ;
Nikolaou, K ;
Rist, C ;
Reiser, M ;
White, C ;
Steinbeck, G ;
Boekstegers, P .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) :1241-1247
[8]  
Leipsic J., 2011, INT J CARDIOVASC IMA
[9]   Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography [J].
Meijboom, W. Bob ;
Meijs, Matthijs F. L. ;
Schuijf, Joanne D. ;
Cramer, Maarten J. ;
Mollet, Nico R. ;
van Mieghem, Carlos A. G. ;
Nieman, Koen ;
van Werkhoven, Jacob M. ;
Pundziute, Gabija ;
Weustink, Annick C. ;
de Vos, Alexander M. ;
Pugliese, Francesca ;
Rensing, Benno ;
Jukema, J. Wouter ;
Bax, Jeroen J. ;
Prokop, Mathias ;
Doevendans, Pieter A. ;
Hunink, Myriam G. M. ;
Krestin, Gabriel P. ;
de Feyter, Pim J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (25) :2135-2144
[10]   Diagnostic Performance of Coronary Angiography by 64-Row CT [J].
Miller, Julie M. ;
Rochitte, Carlos E. ;
Dewey, Marc ;
Arbab-Zadeh, Armin ;
Niinuma, Hiroyuki ;
Gottlieb, Ilan ;
Paul, Narinder ;
Clouse, Melvin E. ;
Shapiro, Edward P. ;
Hoe, John ;
Lardo, Albert C. ;
Bush, David E. ;
de Roos, Albert ;
Cox, Christopher ;
Brinker, Jeffery ;
Lima, Joao A. C. .
NEW ENGLAND JOURNAL OF MEDICINE, 2008, 359 (22) :2324-2336