Quantitative photoacoustic imaging: correcting for heterogeneous light fluence distributions using diffuse optical tomography

被引:106
|
作者
Bauer, Adam Q. [1 ]
Nothdurft, Ralph E. [1 ]
Erpelding, Todd N. [2 ]
Wang, Lihong V. [3 ]
Culver, Joseph P. [1 ,3 ]
机构
[1] Washington Univ, Sch Med, Dept Radiol, St Louis, MO 63110 USA
[2] Philips Res N Amer, Briarcliff Manor, NY 10510 USA
[3] Washington Univ, Dept Biomed Engn, St Louis, MO 63130 USA
关键词
quantitative photoacoustic imaging; diffuse optical tomography; light modeling; multimodal imaging; CEREBRAL-BLOOD-FLOW; ABSORPTION-COEFFICIENT; OXYGEN-SATURATION; CARBON NANOTUBES; HIGH-RESOLUTION; RAT; RECOVERY; MEDIA; RECONSTRUCTION; OPTIMIZATION;
D O I
10.1117/1.3626212
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient therefore require an accurate estimation of optical fluence. Light-modeling aided by diffuse optical tomography (DOT) can be used to map the required fluence and to reduce errors in traditional PA spectroscopic analysis. As a proof-of-concept, we designed a tissue-mimicking phantom to demonstrate how fluence-related artifacts in PA images can lead to misrepresentations of tissue properties. To correct for these inaccuracies, the internal fluence in the tissue phantom was estimated by using DOT to reconstruct spatial distributions of the absorption and reduced scattering coefficients of multiple targets within the phantom. The derived fluence map, which only consisted of low spatial frequency components, was used to correct PA images of the phantom. Once calibrated to a known absorber, this method reduced errors in estimated absorption coefficients from 33% to 6%. These results experimentally demonstrate that combining DOT with PA imaging can significantly reduce fluence-related errors in PA images, while producing quantitatively accurate, high-resolution images of the optical absorption coefficient. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3626212]
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Quantitative, high-resolution photoacoustic spectroscopy by combining photoacoustic imaging with diffuse optical tomography
    Bauer, Adam Q.
    Nothdurft, Ralph E.
    Erpelding, Todd N.
    Wang, Lihong V.
    Culver, Joseph P.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [2] Quantitative Photoacoustic Endoscopic Imaging for Correcting Light Fluence Variation
    Meng Qi
    Sun Zheng
    Hou Yingsa
    Sun Meichen
    ACTA OPTICA SINICA, 2023, 43 (01)
  • [3] Listen to photon propagation in biological tissues: Quantitative optical scattering imaging and high-resolution diffuse optical tomography using photoacoustic measurements
    Yuan, Zhen
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [4] Target Detection and Characterization using a Hybrid Handheld Diffuse Optical Tomography and Photoacoustic Tomography System
    Kumavor, Patrick D.
    Aguirre, Andres
    Xu, Chen
    Gamelin, John
    Ardeshirpour, Yasaman
    Tavakoli, Behnoosh
    Zanganeh, Saeid
    Alqasemi, Umar S.
    Zhu, Quing
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [5] Investigation of a Diffuse Optical Tomography-Assisted Quantitative Photoacoustic Tomography in Reflection geometry
    Xu, Chen
    Kumavor, Patrick D.
    Aguirre, Andres
    Zhu, Quing
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899
  • [6] Hybrid co-planar diffuse optical tomography and photoacoustic imaging
    Zarei, M.
    Mahmoodkalayeh, S.
    Ansari, M. A.
    Nasiriavanaki, M. R.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [7] Quantitative photoacoustic tomography with multiple optical sources
    Zemp, Roger J.
    APPLIED OPTICS, 2010, 49 (18) : 3566 - 3572
  • [8] Quantitative photoacoustic imaging using known chromophores as fluence marker
    Thomas, Anjali
    Rietberg, Max
    Akkus, Mervenur
    van Soest, Gijs
    Francis, Kalloor Joseph
    PHOTOACOUSTICS, 2025, 41
  • [9] Integrated diffuse optical tomography and photoacoustic tomography: phantom validations
    Li, Xiaoqi
    Xi, Lei
    Jiang, Ruixin
    Yao, Lei
    Jiang, Huabei
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (08): : 2348 - 2353
  • [10] Reconstructing absorption and scattering distributions in quantitative photoacoustic tomography
    Tarvainen, T.
    Cox, B. T.
    Kaipio, J. P.
    Arridge, S. R.
    INVERSE PROBLEMS, 2012, 28 (08)