Noncontact SpO2 Measurement Using Eulerian Video Magnification

被引:26
作者
Galvao Rosa, Alessandra de Fatima [1 ]
Betini, Roberto Cesar [1 ]
机构
[1] Fed Univ Thchnol Parana, Acad Dept Informat, BR-80230901 Curitiba, Parana, Brazil
关键词
Image photoplethysmography (iPPG); noncontact monitoring; peripheral oxygen saturation (SpO(2)); remote photoplethysmography (rPPG); OXYGEN-SATURATION; PULSE OXIMETRY; HEART-RATE; REFLECTANCE; CALIBRATION; LIGHT;
D O I
10.1109/TIM.2019.2920183
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Peripheral oxygen saturation (SpO(2)) monitoring is critical during surgery and in intensive care units (ICS). Over the last decades, several studies have addressed the noncontact monitoring of vital signs, but few reports have focused on SpO(2). This paper presents an SpO(2) monitoring method without physical contact with the patient using imaging photoplethysmography (iPPG). Eulerian video magnification (EVM) was employed in the proposed solution to amplify the changes in skin color due to the heart cycle. The developed software operates on a widely available, low-cost hardware platform. Experiments were performed with nine healthy individuals. When comparing the experimental SpO(2) results to those obtained with a reference pulse oximeter, the proposed solution showed good accuracy, with differences of less than 2%.
引用
收藏
页码:2120 / 2130
页数:11
相关论文
共 31 条
  • [1] Video-Based Physiologic Monitoring During an Acute Hypoxic Challenge: Heart Rate, Respiratory Rate, and Oxygen Saturation
    Addison, Paul S.
    Jacquel, Dominique
    Foo, David M. H.
    Antunes, Andre
    Borg, Ulf R.
    [J]. ANESTHESIA AND ANALGESIA, 2017, 125 (03) : 860 - 873
  • [2] Monitoring of Cardiorespiratory Signal: Principles of Remote Measurements and Review of Methods
    Al-Naji, Ali
    Gibson, Kim
    Lee, Sang-Heon
    Chahl, Javaan
    [J]. IEEE ACCESS, 2017, 5 : 15776 - 15790
  • [3] [Anonymous], [No title captured]
  • [4] [Anonymous], [No title captured]
  • [5] [Anonymous], [No title captured]
  • [6] Non-contact estimation of heart rate and oxygen saturation using ambient light
    Bal, Ufuk
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (01): : 86 - 97
  • [7] Cobos-Torres JC, 2017, 2017 40TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), P452, DOI 10.1109/TSP.2017.8076026
  • [8] Non-contact remote estimation of cardiovascular parameters
    Fan, Qiang
    Li, Kaiyang
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 40 : 192 - 203
  • [9] THE VALIDITY AND PRACTICALITY OF SUN-REACTIVE SKIN TYPE-I THROUGH TYPE-VI
    FITZPATRICK, TB
    [J]. ARCHIVES OF DERMATOLOGY, 1988, 124 (06) : 869 - 871
  • [10] Non-contact measurement of oxygen saturation with an RGB camera
    Guazzi, Alessandro R.
    Villarroel, Mauricio
    Jorge, Joao
    Daly, Jonathan
    Frise, Matthew C.
    Robbins, Peter A.
    Tarassenko, Lionel
    [J]. BIOMEDICAL OPTICS EXPRESS, 2015, 6 (09): : 3320 - 3338