Polarimetric Laser Range-Gated Underwater Imaging

被引:7
作者
Guan Jin-Ge [1 ,2 ]
Zhu Jing-Ping [1 ,2 ]
Tian Heng [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Key Lab Phys Elect & Devices, Minist Educ, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Shaanxi Key Lab Informat Photon Tech, Xian 710049, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
MEDIA;
D O I
10.1088/0256-307X/32/7/074201
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
For conventional laser range-gated underwater imaging (RGI) systems, the target image is obtained based on the reflective character of the target. One of the main performance limiting factors of conventional RGI is that, when the underwater target has the same reflectivity as the background, it is difficult to distinguish the target from the background. An improvement is to use the polarization components of the reflected light. On the basis of conventional RGI, we propose a polarimetric RGI system that employs a polarization generator and a polarization analyzer to detect and recognize underwater objects. Experimental results demonstrate that, by combining polarization with intensity information, we are better able to enhance identification of the underwater target from other objects of the same reflectivity.
引用
收藏
页数:5
相关论文
共 34 条
  • [1] Scattering noise estimation of range-gated imaging system in turbid condition
    Tan, ChingSeong
    Seet, Gerald
    Sluzek, Andrzej
    Wang, Xin
    Yuen, Chai Tong
    Fam, Chen Yep
    Wong, Hin Yong
    OPTICS EXPRESS, 2010, 18 (20): : 21147 - 21154
  • [2] Polarimetric imaging method for target enhancement in haze based on polarimetric retrieval
    Zhang, Wenfei
    Liang, Jian
    Xing, Fei
    Man, Zhongsheng
    Ge, Xiaolu
    Fu, Shenggui
    JOURNAL OF MODERN OPTICS, 2019, 66 (11) : 1235 - 1243
  • [3] Vessel packaging effect in laser speckle contrast imaging and laser Doppler imaging
    Fredriksson, Ingemar
    Larsson, Marcus
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (10)
  • [4] Magnetomotive laser speckle imaging
    Kim, Jeehyun
    Oh, Junghwan
    Choi, Bernard
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (01)
  • [5] Ultrahigh polarimetric image contrast enhancement for skin cancer diagnosis using InN plasmonic nanoparticles in the terahertz range
    Ney, Michael
    Abdulhalim, Ibrahim
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (12)
  • [6] Long-Range EM Communication Underwater With Ultracompact ELF Magneto-Mechanical Antenna
    Yang, Silei
    Geng, Junping
    Zhou, Han
    Wang, Kun
    Zhao, Xiaonan
    Lu, Jingzheng
    Zhao, Rui
    Tang, Xudong
    Zhang, Yangzhou
    Su, Da
    Zhang, Ao
    Li, Haotian
    Jin, Ronghong
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2023, 71 (03) : 2082 - 2097
  • [7] Imaging a photodynamic therapy photosensitizer in vivo with a time-gated fluorescence tomography system
    Mo, Weirong
    Rohrbach, Daniel
    Sunar, Ulas
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (07)
  • [8] Modeling of Medium- and Long-Range Electromagnetic Communication Channel for Underwater Wireless Sensor Networks
    Ren, Yingda
    Wang, Honglei
    Yang, Kunde
    IEEE SENSORS JOURNAL, 2024, 24 (15) : 24865 - 24879
  • [9] Terahertz polarimetric imaging of biological tissue: Monte Carlo modeling of signal contrast mechanisms due to Mie scattering
    Xu, Kuangyi
    Arbab, M. Hassan
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (04): : 2328 - 2342
  • [10] All-In-Focus Polarimetric Imaging Based on an Integrated Plenoptic Camera with a Key Electrically Tunable LC Device
    Chen, Mingce
    Li, Zhexun
    Ye, Mao
    Liu, Taige
    Hu, Chai
    Shi, Jiashuo
    Liu, Kewei
    Wang, Zhe
    Zhang, Xinyu
    MICROMACHINES, 2022, 13 (02)