A Simple Perceptive Diphenyl-Imidazole-Based Dipodal Schiff-Base Chemosensor for Zn2+ and PPi ions and Its Live-Cell Imaging Applications

被引:15
|
作者
Gomathi, Asaithambi [1 ]
Vasanthi, Mani [1 ]
Viswanthamurthi, Periasamy [1 ]
Suresh, Shanmugan [2 ]
Nandhakumar, Raju [2 ]
机构
[1] Periyar Univ, Dept Chem, Salem 636011, India
[2] Karunya Univ, Dept Chem, Coimbatore 641114, Tamil Nadu, India
来源
CHEMISTRYSELECT | 2018年 / 3卷 / 42期
关键词
Detection Limit; Fluorescent Probe; Live Cell Imaging; Pyrophosphate Ion Detection; Zinc Ion Detection; SEQUENTIAL DETECTION; FLUORESCENT SENSOR; HYDROGEN-SULFIDE; ZINC; PYROPHOSPHATE; RECOGNITION; PROBE; RESPONSES; PICOMOLAR; AFFINITY;
D O I
10.1002/slct.201802233
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
2,6-bis((E)-(2-(benzo[d]thiazol-2-yl)hydrazono)methyl)-4-(4,5-diphenyl-1H-imidazol-2-yl)phenol (PIS) conjugate has been designed as a selective fluorescent probe for zinc ion. The PIS exhibits selectivity towards Zn2+ among various ions in DMSO-H2O (1:9) v/v 50 mM HEPES (4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid) at pH=7.4. Moreover, the detection of PIS towards Zn2+ ion could be realized in (")naked eye" with a color conversion from yellow to greenish yellow. The linear relationship between fluorescence intensity and Zn2+ ion concentration indicates that PIS can be used for quantification of Zn2+ ion. The PIS probe can be used in broad pH ranging from 4 to 9. The limit of detection (LOD) was found to be 0.52 nM for Zn2+ ion. The binding ratio and binding constant of PIS-Zn2+ complex were determined and calculated as 1:1 and 2.36x10(6) M-1 according to Job ' s plot and Benesi-Hildebrand equation, respectively. Furthermore, the PIS-Zn2+ complex subsequently acted as a secondary fluorescent turn-off probe for pyrophosphate (PPi) ion recognition among the other anions. To assess the real-world efficacy of the PIS and PIS-Zn2+ complex, they were evaluated by test paper strips. Likewise, the probe PIS and PIS-Zn2+ complex were used as in vitro cell imaging probe, and successfully demonstrated as feasible bio-marker as well.
引用
收藏
页码:11809 / 11815
页数:7
相关论文
共 50 条
  • [31] A new fluorescent chemosensor for Zn2+ with facile synthesis: "Turn-on" response in water at neutral pH and its application for live cell imaging
    Li, Kai
    Tong, Aijun
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 184 : 248 - 253
  • [32] New pyridoxal based chemosensor for selective detection of Zn2+: Application in live cell imaging and phosphatase activity response
    Mandal, Senjuti
    Sikdar, Yeasin
    Malti, Dilip K.
    Sanyal, Ria
    Das, Debasis
    Mukherjee, Abhishek
    Mandal, Sushil Kumar
    Biswas, Jayanta Kumar
    Bauza, Antonio
    Frontera, Antonio
    Goswami, Sanchita
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2017, 334 : 86 - 100
  • [33] A highly selective coumarin-based chemosensor for dual sensing of Cu2+ and Zn2+ ions with logic gate integration and live cell imaging
    Singh, Avanish Kumar
    Singh, Amit Kumar
    Sharma, Shashi Kant
    Sonkar, Vijay Kumar
    Singh, Vinod P.
    ANALYTICAL METHODS, 2024, 16 (27) : 4551 - 4560
  • [34] "On-off-on" pyrene-based fluorescent chemosensor for the selective recognition of Cu2+ and S2- ions and its utilization in live cell imaging
    Rajasekaran, Dhivya
    Venkatachalam, Kavitha
    Periasamy, Viswanathamurthi
    APPLIED ORGANOMETALLIC CHEMISTRY, 2020, 34 (03)
  • [35] Differentially Selective Chemosensor with Fluorescence Off-On Responses on Cu2+ and Zn2+ Ions in Aqueous Media and Applications in Pyrophosphate Sensing, Live Cell Imaging, and Cytotoxicity
    Anbu, Sellamuthu
    Ravishankaran, Rajendran
    Guedes da Silva, M. Fatima C.
    Karande, Anjali A.
    Pombeiro, Armando J. L.
    INORGANIC CHEMISTRY, 2014, 53 (13) : 6655 - 6664
  • [36] RETRACTED: A new quinoline-based chemosensor for Zn2+ ions and their application in living cell imaging (Retracted Article)
    Ponnuvel, Kandasamy
    Kumar, Madasamy
    Padmini, Vediappen
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 227 : 242 - 247
  • [37] A novel acylhydrazone-based derivative as dual -mode chemosensor for Al3+, Zn2+ and Fe3+ and its applications in cell imaging
    Liao, Zhuang
    Liu, Yang
    Han, Su-Fang
    Wang, Dan
    Zheng, Jian-Quan
    Zheng, Xiang-Jun
    Jin, Lin-Pei
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 244 : 914 - 921
  • [38] A novel schiff base fluorescent probe based on coumarin and benzothiazole for sequential detection of Al3+ and PPi and its applicability in live cell imaging
    Li, Shengling
    Cao, Duanlin
    Meng, Xianjiao
    Hu, Zhiyong
    Li, Zhichun
    Yuan, Changchun
    Zhou, Tao
    Han, Xinghua
    Ma, Wenbing
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2020, 392
  • [39] Easy, selective and colorimetric detection of Zn(II), Cu(II), F -ions by a new piperazine based Schiff base chemosensor along with molecular logic gate formation and live cell images study
    Das, Pranabendu
    Rajput, Swati Singh
    Das, Manik
    Laha, Soumik
    Choudhuri, Indranil
    Bhattacharyya, Nandan
    Das, Arindam
    Samanta, Bidhan Chandra
    Alam, Md. Mehboob
    Maity, Tithi
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2022, 427
  • [40] Pyrene Based Schiff Base for Cascade Fluorescent "On-Off" Detection of Aluminium(III) and Fluoride Ions and its Applications in Live Cells Imaging
    Bhardwaj, Kanishk
    Yadav, Rashmi
    Samanta, Animesh
    Jangir, Ritambhara
    Jali, Bigyan Ranjan
    Kumar, S. K. Ashok
    Sahoo, Suban K.
    CHEMISTRY & BIODIVERSITY, 2025, 22 (02)