Validation of Noninvasive Remote Dielectric Sensing System to Quantify Lung Fluid Levels

被引:23
作者
Imamura, Teruhiko [1 ]
Gonoi, Wataru [2 ]
Hori, Masakazu [1 ]
Ueno, Yohei [1 ]
Narang, Nikhil [3 ]
Onoda, Hiroshi [1 ]
Tanaka, Shuhei [1 ]
Nakamura, Makiko [1 ]
Kataoka, Naoya [1 ]
Ushijima, Ryuichi [1 ]
Sobajima, Mitsuo [1 ]
Fukuda, Nobuyuki [1 ]
Ueno, Hiroshi [1 ]
Kinugawa, Koichiro [1 ]
机构
[1] Univ Toyama, Dept Internal Med 2, Toyama 9300194, Japan
[2] Univ Tokyo, Grad Sch Med, Dept Radiol, Tokyo 1138654, Japan
[3] Advocate Christ Med Ctr, Oak Lawn, IL 60453 USA
关键词
congestion; heart failure; hemodynamics; CT densitometry; COMPUTED-TOMOGRAPHY; HEART-FAILURE; CT; TECHNOLOGY; CONGESTION; DIAGNOSIS;
D O I
10.3390/jcm11010164
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The accuracy of the remote dielectric sensing (ReDSTM) system, which is a noninvasive electromagnetic-based technology to quantify lung fluid levels, particularly among those with small body size, remains uncertain. Methods: Hospitalized patients with and without heart failure underwent assessment of lung fluid levels with ReDS and successive chest computed tomography imaging. We performed a correlation analysis of the ReDS measurement, representing lung fluid levels, and computed tomography-derived high attenuation area percentage, which also provides a spatial quantification of lung fluid level. Results: A total of 46 patients (median 76 years old, 28 men), including 28 patients with heart failure, were included. The median ReDS value was 28% (interquartile: 23%, 33%), and the median percentage of high attenuation area was 21.6% (14.4%, 28.5%). ReDS values and percentage of high attenuation area were moderately correlated (r = 0.65, p < 0.001), irrespective of the existence of heart failure. ReDS value independently predicted the percentage of high attenuation area seen on computed tomography (p < 0.001). Conclusions: The ReDS system may be a promising, noninvasive tool to quantify fluid lung levels, as validated by comparison with chest computed tomography imaging. Further studies are warranted to validate the utility and applicability of this technology to a variety of clinical scenarios.
引用
收藏
页数:10
相关论文
共 20 条
[1]   Evaluation of remote dielectric sensing (ReDS) technology-guided therapy for decreasing heart failure re-hospitalizations [J].
Amir, Offer ;
Ben-Gal, Tuvia ;
Weinstein, JeanMarc ;
Schliamser, Jorge ;
Burkhoff, Daniel ;
Abbo, Aharon ;
Abraham, William T. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2017, 240 :279-284
[2]   Validation of remote dielectric sensing (ReDS™) technology for quantification of lung fluid status: Comparison to high resolution chest computed tomography in patients with and without acute heart failure [J].
Amir, Offer ;
Azzam, Zaher S. ;
Gaspar, Tamar ;
Faranesh-Abboud, Suzan ;
Andria, Nizar ;
Burkhoff, Daniel ;
Abbo, Aharon ;
Abraham, William T. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 221 :841-846
[3]  
Amir Offer, 2013, Congest Heart Fail, V19, P149, DOI 10.1111/chf.12021
[4]   Empagliflozin in Heart Failure with a Preserved Ejection Fraction [J].
Anker, Stefan D. ;
Butler, Javed ;
Filippatos, Gerasimos ;
Ferreira, Joao P. ;
Bocchi, Edimar ;
Boehm, Michael ;
Brunner-La Rocca, Hans-Peter ;
Choi, Dong-Ju ;
Chopra, Vijay ;
Chuquiure-Valenzuela, Eduardo ;
Giannetti, Nadia ;
Gomez-Mesa, Juan Esteban ;
Janssens, Stefan ;
Januzzi, James L. ;
Gonzalez-Juanatey, Jose R. ;
Merkely, Bela ;
Nicholls, Stephen J. ;
Perrone, Sergio V. ;
Pina, Ileana L. ;
Ponikowski, Piotr ;
Senni, Michele ;
Sim, David ;
Spinar, Jindrich ;
Squire, Iain ;
Taddei, Stefano ;
Tsutsui, Hiroyuki ;
Verma, Subodh ;
Vinereanu, Dragos ;
Zhang, Jian ;
Carson, Peter ;
Lam, Carolyn Su Ping ;
Marx, Nikolaus ;
Zeller, Cordula ;
Sattar, Naveed ;
Jamal, Waheed ;
Schnaidt, Sven ;
Schnee, Janet M. ;
Brueckmann, Martina ;
Pocock, Stuart J. ;
Zannad, Faiez ;
Packer, Milton .
NEW ENGLAND JOURNAL OF MEDICINE, 2021, 385 (16) :1451-1461
[5]   Simple quantitative chest CT for pulmonary edema [J].
Barile, Maria ;
Hida, Tomoyuki ;
Hammer, Mark ;
Hatabu, Hiroto .
EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2020, 7
[6]   Right heart catheterisation: indications and interpretation [J].
Callan, Paul ;
Clark, Andrew L. .
HEART, 2016, 102 (02) :147-157
[7]   Normal lung attenuation distribution and lung volume on computed tomography in a Chinese population [J].
Cheng, Ting ;
Li, Yong ;
Pang, Shuai ;
Wan, HuanYing ;
Shi, GuoChao ;
Cheng, QiJian ;
Li, QingYun ;
Pan, ZiLai ;
Huang, ShaoGuang .
INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2019, 14 :1657-1668
[8]   CT densitometry in emphysema: a systematic review of its clinical utility [J].
Crossley, Diana ;
Renton, Mary ;
Khan, Muhammad ;
Low, Emma V. ;
Turner, Alice M. .
INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 :547-563
[9]   What has computed tomography taught us about the acute respiratory distress syndrome? [J].
Gattinoni, L ;
Caironi, P ;
Pelosi, P ;
Goodman, LR .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (09) :1701-1711
[10]   Integrative Assessment of Congestion in Heart Failure Throughout the Patient Journey [J].
Girerd, Nicolas ;
Seronde, Marie-France ;
Coiro, Stefano ;
Chouihed, Tahar ;
Bilbault, Pascal ;
Braun, Francois ;
Kenizou, David ;
Maillier, Bruno ;
Nazeyrollas, Pierre ;
Roul, Gerard ;
Fillieux, Ludivine ;
Abraham, William T. ;
Januzzi, James, Jr. ;
Sebbag, Laurent ;
Zannad, Faiez ;
Mebazaa, Alexandre ;
Rossignol, Patrick .
JACC-HEART FAILURE, 2018, 6 (04) :273-285