Experimental Study of the Leakage Flow in an Axial-Flow Fan at Variable Loading

被引:5
|
作者
Canepa, Edward [1 ]
Cattanei, Andrea [1 ]
Moradi, Mehrdad [1 ]
Nilberto, Alessandro [1 ]
机构
[1] DIME Univ Genova, Dipartimento Ingn Meccan Energet Gest & Trasporti, Via Montallegro, I-16145 Genoa, Italy
关键词
axial-flow fan; rotating shroud; leakage flow; fan noise; PIV; PARTICLE IMAGE VELOCIMETRY; TIP CLEARANCE NOISE; SPEED;
D O I
10.3390/ijtpp6040040
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The present paper reports a 2D-PIV (particle image velocimetry) study of the effect of the operating point on the leakage flow in a low-speed ring fan. First, the flow pattern has been studied at 12 operating points covering the whole characteristic curve. At very low loading, the leakage flow streams along the rotor ring and is directly reingested; then, a separation bubble attached to the ring forms that, approaching the design point, modifies in a flow streaming radially outward. As the loading further increases, a separated flow region appears in the blade tip region that finally merges with the leakage flow. A further, more detailed study has been performed at eight operating points in the neighborhood of the design one. Very small loading variations may yield the leakage flow pattern modification, but no intermittence is present during the transition, as instantaneous flow patterns of any intermediate type continuously alternate. These results provide a consistent explanation for the ones of previous acoustic measurements.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] AXIAL-FLOW FAN-BLADE MATERIALS
    VOLKOV, AS
    MARKOV, AA
    RUSSIAN ENGINEERING JOURNAL, 1974, 54 (05): : 46 - 47
  • [22] Experimental investigation of tip-leakage flow in an axial flow fan at various flow rates
    Lee, Hongkwon
    Park, Keuntae
    Choi, Haecheon
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2019, 33 (03) : 1271 - 1278
  • [23] Instantaneous PIV data related to the leakage flow of a low-speed axial-flow fan with rotating shroud
    Canepa, Edward
    Cattanei, Andrea
    Zecchin, Fabio Mazzocut
    Parodi, Davide
    DATA IN BRIEF, 2019, 24
  • [24] Numerical simulation and experimental study of the interior flow in axial-flow pump
    Li, Zhong
    Yang, Min-Guan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (11): : 1847 - 1850
  • [25] The influence of axial-flow fan trailing edge structure on internal flow
    Zhang, Weijie
    Yuan, Jianping
    Zhou, Banglun
    Li, Hao
    Yuan, Ye
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (11)
  • [26] A computational study of the interaction noise from a small axial-flow fan
    Lu, H. Z.
    Huang, Lixi
    So, R. M. C.
    Wang, J.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (03): : 1404 - 1415
  • [27] Optimization of the Aerodynamic and Aeroacoustic Performance of an Axial-Flow Fan
    Kim, Jin-Hyuk
    Ovgor, Bavuudorj
    Cha, Kyung-Hun
    Kim, Joo-Hyung
    Lee, Seungbae
    Kim, Kwang-Yong
    AIAA JOURNAL, 2014, 52 (09) : 2032 - 2044
  • [28] THE EFFECT OF TIP CLEARANCE ON THE PERFORMANCE OF AN AXIAL-FLOW FAN
    VENTER, SJ
    KROGER, DG
    ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (02) : 89 - 97
  • [29] EXPERIMENTAL STUDY ON ENERGY CHARACTERISTICS OF AXIAL-FLOW PUMPS
    Zheng, Yuan
    Hu, Ming
    Xu, Feng
    Zhang, Jingxuan
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER CONFERENCE, VOL 2, 2006, : 937 - 940
  • [30] On the Nature of Transonic Shock Buffet in an Axial-Flow Fan
    Majhi, Jyoti Ranjan
    Venkatraman, Kartik
    AIAA JOURNAL, 2023, 61 (12) : 5390 - 5403