Experimental Study of the Leakage Flow in an Axial-Flow Fan at Variable Loading

被引:5
|
作者
Canepa, Edward [1 ]
Cattanei, Andrea [1 ]
Moradi, Mehrdad [1 ]
Nilberto, Alessandro [1 ]
机构
[1] DIME Univ Genova, Dipartimento Ingn Meccan Energet Gest & Trasporti, Via Montallegro, I-16145 Genoa, Italy
关键词
axial-flow fan; rotating shroud; leakage flow; fan noise; PIV; PARTICLE IMAGE VELOCIMETRY; TIP CLEARANCE NOISE; SPEED;
D O I
10.3390/ijtpp6040040
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The present paper reports a 2D-PIV (particle image velocimetry) study of the effect of the operating point on the leakage flow in a low-speed ring fan. First, the flow pattern has been studied at 12 operating points covering the whole characteristic curve. At very low loading, the leakage flow streams along the rotor ring and is directly reingested; then, a separation bubble attached to the ring forms that, approaching the design point, modifies in a flow streaming radially outward. As the loading further increases, a separated flow region appears in the blade tip region that finally merges with the leakage flow. A further, more detailed study has been performed at eight operating points in the neighborhood of the design one. Very small loading variations may yield the leakage flow pattern modification, but no intermittence is present during the transition, as instantaneous flow patterns of any intermediate type continuously alternate. These results provide a consistent explanation for the ones of previous acoustic measurements.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan
    Lee, GH
    Baek, JH
    Myung, HJ
    HVAC&R RESEARCH, 2005, 11 (01): : 95 - 117
  • [2] Structure of tip leakage flow in a forward-swept axial-flow fan
    Lee, GH
    Baek, JH
    Myung, HJ
    FLOW TURBULENCE AND COMBUSTION, 2003, 70 (1-4) : 241 - 265
  • [3] Numerical Study of Blade Loading Effects on Tip Leakage Flow in Axial-flow Pump
    Yang W.
    Yang K.
    Fu Z.
    Wu J.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2022, 53 (06): : 177 - 183
  • [4] Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan
    Gong Hee Lee
    Je Hyun Baek
    Hwan Joo Myung
    Flow, Turbulence and Combustion, 2003, 70 : 241 - 265
  • [5] EFFECTS OF ACOUSTIC LOADING ON AXIAL-FLOW FAN NOISE GENERATION
    BAADE, PK
    NOISE CONTROL ENGINEERING JOURNAL, 1977, 8 (01) : 5 - 15
  • [6] Leakage flow flutter in a low-speed axial-flow fan with shrouded blades
    Carassale, Luigi
    Cattanei, Andrea
    Zecchin, Fabio Mazzocut
    Moradi, Mehrdad
    JOURNAL OF SOUND AND VIBRATION, 2020, 475
  • [7] FLOW VISUALIZATION AROUND AXIAL-FLOW FAN BLADES
    KAWAGUCHI, K
    MATSUI, K
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1986, 29 (248): : 466 - 475
  • [8] Study of the clearance leakage flow characteristics of a transonic axial-flow compressor
    College of Power and Energy Source, Northwestern Polytechnical University, Xi'an 710072, China
    Reneng Dongli Gongcheng, 2008, 5 (473-477):
  • [9] The aerodynamic design and experimental research on high-speed axial-flow fan applied in the axial-flow pneumatic extinguisher
    Chu, Shuang-Lei
    Yu, Guo-Sheng
    Qin, Rui-Hong
    Kongqi Donglixue Xuebao/Acta Aerodynamica Sinica, 2010, 28 (05): : 565 - 570
  • [10] Experimental study at the exit flow field of an axial flow fan with variable setting angle
    Chen, Haisheng
    Liang, Xizhi
    Tan, Chunqing
    Kang, Shun
    Meitan Xuebao/Journal of China Coal Society, 2000, 25 (04): : 412 - 415