Salvage procedures for trochanteric femoral fractures after internal fixation failure: Biomechanical comparison of a plate fixator and the dynamic condylar screw

被引:13
作者
Konstantinidis, L. [1 ]
Papaioannou, C. [1 ]
Mehlhorn, A. [1 ]
Hirschmueller, A. [1 ]
Suedkamp, N. P. [1 ]
Helwig, P. [1 ]
机构
[1] Univ Freiburg, Dept Orthoped & Trauma Surg, D-79106 Freiburg, Germany
关键词
salvage procedure; trochanteric fracture; biomechanics; LISS-DF; DCS; FINITE-ELEMENT-ANALYSIS; LOCKING PLATES; INTERTROCHANTERIC FRACTURES; HIP-FRACTURES; FEMUR; COMPLICATIONS; MANAGEMENT; NAIL;
D O I
10.1177/0954411911402133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was the biomechanical evaluation of the reversed less invasive stabilization system (LISS) internal fixation as a joint-preserving salvage procedure for trochanteric fractures. Five LISS plates and five dynamic condylar screws (DCS) were tested using synthetic femora (Sawbones (R)) with an osteotomy model similar to a type-A2.3 pertrochanteric fracture. The constructs were subjected to axial loading up to 1000 N for five cycles. Then, the force was continuously increased until fixation failure. For the evaluation of the biomechanical behaviour, the stiffness levels were recorded and the osteotomy gap displacement was mapped three-dimensionally. The average stiffness for the constructs with LISS plates was 412 N/mm (with a standard deviation (SD) of 103N/mm) and 572 N/mm (SD of 116 N/mm) for the DCS constructs (p = 0.051). Local displacement at the osteotomy gap did not yield any significant differences. The LISS constructs failed at a mean axial compression of 2103 N (SD of 519 N) and the DCS constructs at a mean of 2572N (SD of 372 N) (p = 0.14). It is concluded that the LISS plate offers a reliable fixation alternative for salvage procedures.
引用
收藏
页码:710 / 717
页数:8
相关论文
共 29 条
[1]   Complications and technical problems with the gamma nail [J].
Albareda, J ;
Laderiga, A ;
Palanca, D ;
Paniagua, L ;
Seral, F .
INTERNATIONAL ORTHOPAEDICS, 1996, 20 (01) :47-50
[2]   Vertically oriented femoral neck fractures: Mechanical analysis of four fixation techniques [J].
Aminian, Arash ;
Gao, Fan ;
Fedoriw, Wasyl W. ;
Zhang, Li-Qun ;
Kalainov, David M. ;
Merk, Bradley R. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (08) :544-548
[3]   Salvage of Failed Hip Fracture Fixation [J].
Angelini, Mark ;
McKee, Michael D. ;
Waddell, James P. ;
Haidukewych, George ;
Schemitsch, Emil H. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (06) :471-478
[4]   Locking Plates for Extremity Fractures [J].
Anglen, Jeffrey ;
Kyle, Richard F. ;
Marsh, John Lawrence ;
Virkus, Walter W. ;
Watters, William C., III ;
Keith, Michael Warren ;
Turkelson, Charles M. ;
Wies, Janet L. ;
Boyer, Kevin M. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2009, 17 (07) :465-472
[5]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[6]   Biomechanical Analysis of Lumbar Spine after Implantation of a Disk Prosthesis and Supplementary Spinal Fusion for Management of Complications [J].
Birnbaum, K. ;
Phoa, T. ;
Maus, U. ;
Prescher, A. ;
Weisskopf, M. .
ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2009, 147 (04) :493-500
[7]  
BONNAIRE F, 1992, UNFALLCHIRURG, V95, P246
[8]   Cutting out in pertrochanteric fractures -: problem of osteoporosis? [J].
Bonnaire, F. ;
Weber, A. ;
Boesl, O. ;
Eckhardt, C. ;
Schwieger, K. ;
Linke, B. .
UNFALLCHIRURG, 2007, 110 (05) :425-432
[9]   A Biomechanical Comparison of Locked Plate Fixation With Percutaneous Insertion Capability Versus the Angled Blade Plate in a Subtrochanteric Fracture Gap Model [J].
Crist, Brett D. ;
Khalafi, Afshin ;
Hazelwood, Scott J. ;
Lee, Mark A. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) :622-627
[10]   Mechanical validation of whole bone composite femur models [J].
Cristofolini, L ;
Viceconti, M ;
Cappello, A ;
Toni, A .
JOURNAL OF BIOMECHANICS, 1996, 29 (04) :525-535