Contrast-enhanced computerized tomography combined with a targeted nanoparticle contrast agent for screening for early-phase non-small cell lung cancer

被引:5
|
作者
Yuan, Ninglu [1 ]
Zhang, Xiaohe [2 ]
Cao, Yonghui [1 ]
Jiang, Xiaojie [3 ]
Zhao, Si [1 ]
Feng, Yingying [1 ]
Fan, Yimeng [3 ]
Lu, Zhitao [1 ]
Gao, Hongmei [1 ]
机构
[1] First Hosp Shijiazhuang City, Dept Radiol, 36 Fanxi Rd, Shijiazhuang 050011, Hebei, Peoples R China
[2] First Hosp Shijiazhuang City, Dept Cardiothorac Surg, Shijiazhuang 050011, Hebei, Peoples R China
[3] First Hosp Shijiazhuang City, Dept Computerized Tomog, Shijiazhuang 050011, Hebei, Peoples R China
关键词
non-small cell lung cancer; contrast-enhanced computerized tomography; nanoscale microbubble; liposome-encapsulated lenvatinib; OF-THE-LITERATURE; PROLONGED SURVIVAL; BREAST-CANCER; LYMPH-NODES; NSCLC; CT; DIAGNOSIS; METASTASIS; TUMORS; MRI;
D O I
10.3892/etm.2017.5140
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Non-small cell lung cancer (NSCLC) is a major cause of morbidity and mortality, and patients with NSCLC are frequently diagnosed at an advanced stage. This is primarily due to a lack of advanced and sensitive protocols for the detection of early stage NSCLC. Therefore, methods for the accurate diagnosis of early stage NSCLC are urgently required to improve survival rates. The present study investigated the use of contrast-enhanced computerized tomography (CECT) combined with a targeted nanoparticle contrast agent (TNCA) to diagnose early-stage NSCLC in a mice xenograft model. The TNCA used was lenvatinib, a multi-target tyrosine kinase inhibitor that inhibits vascular endothelial growth factor receptor 1-3, fibroblast growth factor receptor 1-4, platelet-derived growth factor receptor beta, proto-oncogene tyrosine-protein kinase receptor Ret and mast/stem cell growth factor receptor Kit. Xenograft NSCLC mice were established and used to analyze the efficacy of CECT-TNCA compared with CT scanning alone. The TNCA was inhaled with the use of an atomizer. The results demonstrated that CECT-TNCA improved the sensitivity of the diagnosis of early stage NSCLC. In addition, imaging using the TNCA enabled the visualization of nodules in the lung in mice with early stage NSCLC. In addition, lung nodule signal enhancement was increased in CECT-TNCA compared with CT, suggesting a high accurate accumulation of the TNCA in tumor nodules. Mice diagnosed with early stage NSCLC exhibited a higher eradication rate of NSCLC after treatment with cisplatin compared with mice with advanced stage NSCLC. These data indicate that the sensitivity and accuracy of CT imaging for the diagnosis of early stage NSCLC was improved through combination with the liposome-encapsulated TNCA.
引用
收藏
页码:5063 / 5068
页数:6
相关论文
共 50 条
  • [1] Contrast-enhanced ultrasound with a novel nanoparticle contrast agent for clinical diagnosis in patients with non-small cell lung cancer
    Li, Na
    Han, Lu
    Jing, Hui
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2017, 14 (04) : 3768 - 3773
  • [2] Application of novel targeting nanoparticles contrast agent combined with contrast-enhanced computed tomography during screening for early-phase gastric carcinoma
    Zhang, Kaimin
    Du, Xijian
    Yu, Kaihu
    Zhang, Kaiyu
    Zhou, Yicheng
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 15 (01) : 47 - 54
  • [3] Early evaluation of targeted therapy effectiveness in non-small cell lung cancer by dynamic contrast-enhanced CT
    Qiao, P. -G.
    Zhang, H. -T.
    Zhou, J.
    Li, M.
    Ma, J. -L.
    Tian, N.
    Xing, X. -D.
    Li, G. -J.
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2016, 18 (01): : 47 - 57
  • [4] Early evaluation of targeted therapy effectiveness in non-small cell lung cancer by dynamic contrast-enhanced CT
    P.-G. Qiao
    H.-T. Zhang
    J. Zhou
    M. Li
    J.-L. Ma
    N. Tian
    X.-D. Xing
    G.-J. Li
    Clinical and Translational Oncology, 2016, 18 : 47 - 57
  • [5] The value of contrast-enhanced computed tomography in evaluating patient response to Icotinib for non-small cell lung cancer
    Yu, Jinping
    Liu, Haixia
    Chen, Hong
    Ren, Shuhua
    BIOMEDICAL RESEARCH-INDIA, 2016, 27 (03): : 905 - 911
  • [6] Relationship between Contrast-Enhanced CT and Clinicopathological Characteristics and Prognosis of Non-Small Cell Lung Cancer
    Yang, Hai
    Fan, Heng-Xin
    Song, Li-Hong
    Xie, Ji-Cheng
    Fan, Shu-Feng
    ONCOLOGY RESEARCH AND TREATMENT, 2017, 40 (09) : 516 - 522
  • [7] Screening for brain metastases in patients with stage III non-small cell lung cancer: Is there additive value of magnetic resonance imaging above a contrast-enhanced computed tomography of the brain?
    Hendriks, Lizza E. L.
    Bootsma, Gerben P.
    de Ruysscher, Dirk K. M.
    Scheppers, Nicole A. M.
    Hofmane, Paul A. M.
    Brans, Boudewijn T.
    Dingemans, Anne-Marie C.
    LUNG CANCER, 2013, 80 (03) : 293 - 297
  • [8] Ultrasonic diagnosis combined with targeted ultrasound contrast agent improves diagnostic sensitivity of ultrasonic for non-small cell lung cancer patients
    Zhang, Xiaohong
    Xiao, Can
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2018, 16 (02) : 908 - 916
  • [9] Detection of nodal metastatic disease in patients with non-small cell lung cancer: comparison of positron emission tomography (PET), contrast-enhanced computed tomography (CT), and combined PET-CT
    Ventura, Elisa
    Islam, Tina
    Gee, Michael S.
    Mahmood, Umar
    Braschi, Marta
    Harisinghani, Mukesh G.
    CLINICAL IMAGING, 2010, 34 (01) : 20 - 28
  • [10] Semiautomatic Determination of Arterial Input Functions for Quantitative Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Non-Small Cell Lung Cancer Patients
    Chung, Julius
    Kim, Jae-Hun
    Lee, Eun Ju
    Kim, Yoo Na
    Yi, Chin A.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (03) : 129 - 134