Fibre optic sensors for temperature and pressure monitoring in laser ablation: experiments on ex vivo animal model

被引:0
作者
Tosi, Daniele [1 ]
Saccomandi, Paola [2 ]
Schena, Emiliano [2 ]
Duraibabu, Dinesh B. [3 ]
Poeggel, Sven [3 ]
Adilzhan, Abzal [1 ]
Aliakhmet, Kamilla [1 ]
Silvestri, Sergio [2 ]
Leen, Gabriel [3 ]
Lewis, Elfed [3 ]
机构
[1] Nazarbayev Univ, Sch Engn, 53 Kabanbay Batyr, Astana 01000, Kazakhstan
[2] Univ Campus Biomed Roma, Ctr Integrated Res, Unit Measurements & Biomed Instrumentat, I-00128 Rome, Italy
[3] Univ Limerick, Opt Fibre Sensors Res Ctr, Limerick, Ireland
来源
SIXTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS | 2016年 / 9916卷
关键词
Optical fibre sensors (OFS); Fibre Bragg Grating (FBG); Fabry-Perot Interferometry (FPI); pressure sensor; temperature sensor; laser ablation (LA); medical measurement; RADIOFREQUENCY THERMAL ABLATION; LIVER; THERMOTHERAPY; TISSUE;
D O I
10.1117/12.2235470
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical fibre sensors have been applied to perform biophysical measurement in ex-vivo laser ablation (LA), on pancreas animal phantom. Experiments have been performed using Fibre Bragg Grating (FBG) arrays for spatially resolved temperature detection, and an all-glass Extrinsic Fabry-Perot Interferometer (EFPI) for pressure measurement. Results using a Nd:YAG laser source as ablation device, are presented and discussed.
引用
收藏
页数:4
相关论文
共 14 条
[1]   Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia [J].
Dewhirst, MW ;
Viglianti, BL ;
Lora-Michiels, M ;
Hanson, M ;
Hoopes, PJ .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2003, 19 (03) :267-294
[2]   Radiofrequency ablation versus surgical resection for the treatment of hepatocellular carcinoma in cirrhosis [J].
Guglielmi, Alfredo ;
Ruzzenente, Andrea ;
Valdegamberi, Alessandro ;
Pachera, Silvia ;
Campagnaro, Tommaso ;
D'Onofrio, Mirko ;
Martone, Enrico ;
Nicoli, Paola ;
Iacono, Calogero .
JOURNAL OF GASTROINTESTINAL SURGERY, 2008, 12 (01) :192-198
[3]  
Liu Y., 2015, 3 INT C BIOPH
[4]   Optical fiber sensors-based temperature distribution measurement in ex vivo radiofrequency ablation with submillimeter resolution [J].
Macchi, Edoardo Gino ;
Tosi, Daniele ;
Braschi, Giovanni ;
Gallati, Mario ;
Cigada, Alfredo ;
Busca, Giorgio ;
Lewis, Elfed .
JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (11)
[5]   Techniques for temperature monitoring during laser-induced thermotherapy: An overview [J].
Saccomandi, Paola ;
Schena, Emiliano ;
Silvestri, Sergio .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2013, 29 (07) :609-619
[6]   Theoretical Analysis and Experimental Evaluation of Laser-Induced Interstitial Thermotherapy in Ex Vivo Porcine Pancreas [J].
Saccomandi, Paola ;
Schena, Emiliano ;
Caponero, Michele Arturo ;
Di Matteo, Francesco Maria ;
Martino, Margareth ;
Pandolfi, Monica ;
Silvestri, Sergio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (10) :2958-2964
[7]   THERMAL DOSE DETERMINATION IN CANCER-THERAPY [J].
SAPARETO, SA ;
DEWEY, WC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (06) :787-800
[8]   Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview [J].
Taffoni, Fabrizio ;
Formica, Domenico ;
Saccomandi, Paola ;
Di Pino, Giovanni ;
Schena, Emiliano .
SENSORS, 2013, 13 (10) :14105-14120
[9]   Monitoring of radiofrequency thermal ablation in liver tissue through fibre Bragg grating sensors array [J].
Tosi, D. ;
Macchi, E. G. ;
Braschi, G. ;
Gallati, M. ;
Cigada, A. ;
Poeggel, S. ;
Leen, G. ;
Lewis, E. .
ELECTRONICS LETTERS, 2014, 50 (14) :981-U91
[10]   Fiber-optic chirped FBG for distributed thermal monitoring of ex-vivo radiofrequency ablation of liver [J].
Tosi, Daniele ;
Macchi, Edoardo Gino ;
Gallati, Mario ;
Braschi, Giovanni ;
Cigada, Alfredo ;
Rossi, Sandro ;
Leen, Gabriel ;
Lewis, Elfed .
BIOMEDICAL OPTICS EXPRESS, 2014, 5 (06) :1799-1811