Characterization of N-terminal formaldehyde adducts to hemoglobin

被引:8
作者
Ospina, Maria [1 ]
Costin, Alina [1 ]
Barry, Adrienne K. [1 ]
Vesper, Hubert W. [1 ]
机构
[1] Ctr Dis Control & Prevent, Div Sci Lab, Natl Ctr Environm Hlth, Atlanta, GA 30341 USA
关键词
STRUCTURAL-CHARACTERIZATION; ACETALDEHYDE ADDUCTS; INHALATION EXPOSURE; MASS-SPECTROMETRY; PROTEIN ADDUCTS; MODEL PEPTIDES; GLOBIN ADDUCTS; IN-VITRO; IDENTIFICATION; ACRYLAMIDE;
D O I
10.1002/rcm.4954
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A procedure to prepare and purify adducts of formaldehyde ( FA) to the N-terminus of peptides was developed. FA-VHLTPEEK and FA-VLSPADK were produced with purities >95% upon incubation of the peptides with FA in phosphate-buffered saline (PBS) at a pH level of 7.4. The peptides were purified by preparative liquid chromatography and were characterized by their retention times in liquid chromatography, their fragmentation patterns obtained by tandem mass spectrometry, and their accurate mass and nuclear magnetic resonance measurements. This is the first time an imidazolidone-type structure has been reported for FA adducts. The same peptides were identified in tryptic digests of human hemoglobin incubated with FA at physiological conditions and in human hemoglobin specimens. These peptides are suitable for use as calibrators for the quantitative assessment of internal exposure to FA. Published in 2011 by John Wiley & Sons, Ltd.
引用
收藏
页码:1043 / 1050
页数:8
相关论文
共 38 条
  • [1] *AG TOX SUBST DIS, 1999, TOX PROF FORM
  • [2] Reaction of (1-azabuta-1,3-diene)tricarbonyliron(0) complexes with sodium borohydride under microwave conditions
    Akisanya, J
    Danks, TN
    Garman, RN
    [J]. JOURNAL OF ORGANOMETALLIC CHEMISTRY, 2000, 603 (02) : 240 - 243
  • [3] [Anonymous], 1999, Integrated Risk Information System (IRIS)
  • [4] [Anonymous], 1989, FORMALDEHYDE
  • [5] [Anonymous], REP CARC
  • [6] Sequence mapping of epoxide adducts in human hemoglobin with LC-tandem MS and the salsa algorithm
    Badghisi, H
    Liebler, DC
    [J]. CHEMICAL RESEARCH IN TOXICOLOGY, 2002, 15 (06) : 799 - 805
  • [7] A novel approach for identification and measurement of hemoglobin adducts with 1,2,3,4-diepoxybutane by liquid chromatography/electrospray ionisation mass spectrometry and matrix-assisted laser desorption/ionisation tandem mass spectrometry
    Basile, A
    Ferranti, P
    Pocsfalvi, G
    Mamone, G
    Miraglia, N
    Caira, S
    Ambrosi, L
    Soleo, L
    Sannolo, N
    Malorni, A
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (08) : 527 - 540
  • [8] Use of haemoglobin adducts in exposure monitoring and risk assessment
    Boogaard, PJ
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 778 (1-2): : 309 - 322
  • [9] Analysis of diepoxide-specific cyclic N-terminal globin adducts in mice and rats after inhalation exposure to 1,3-butadiene
    Boysen, G
    Georgieva, NI
    Upton, PB
    Jayaraj, K
    Li, YT
    Walker, VE
    Swenberg, JA
    [J]. CANCER RESEARCH, 2004, 64 (23) : 8517 - 8520
  • [10] Braun KP, 1997, ALCOHOL CLIN EXP RES, V21, P40