Peri-implant bone loss caused by occlusal overload: Repair of the peri-implant defect following correction of the traumatic occlusion. A case report

被引:1
作者
Tawil, Georges [1 ]
机构
[1] St Joseph Univ, Dept Periodontol, Beirut, Lebanon
关键词
occlusal overload; osseointegration; peri-implant bone loss;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this case report is to demonstrate the relation between occlusal overload and peri-implant bone loss and the reversal of the situation after removal of the offending forces. The placement of an unstable removable prosthesis on 3 well-integrated implants that had been stable for 9 years caused noticeable bone loss after 6 months. The elimination of the traumatic occlusion reversed the situation, and a remarkable healing of the peri-implant tissue occurred until the pretrauma condition was nearly restored. The condition has been stable for the past 4 years.
引用
收藏
页码:153 / 157
页数:5
相关论文
共 33 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] Barbier L, 1997, INT J ORAL MAX IMPL, V12, P215
  • [3] Dimension of the periimplant mucosa - Biological width revisited
    Berglundh, T
    Lindhe, J
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1996, 23 (10) : 971 - 973
  • [4] Evaluation of postsurgical crestal bone levels adjacent to non-submerged dental implants
    Bragger, U
    Hafeli, U
    Huber, B
    Hammerle, CHF
    Lang, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1998, 9 (04) : 218 - 224
  • [5] Biologic width around titanium implants. A histometric analysis of the implanto-gingival junction around unloaded and loaded nonsubmerged implants in the canine mandible
    Cochran, DL
    Hermann, JS
    Schenk, RK
    Higginbottom, FL
    Buser, D
    [J]. JOURNAL OF PERIODONTOLOGY, 1997, 68 (02) : 186 - 197
  • [6] The influence of static and dynamic loading on marginal bone reactions around osseointegrated implants: an animal experimental study
    Duyck, J
    Ronold, HJ
    Van Oosterwyck, H
    Naert, I
    Sloten, JV
    Ellingsen, JE
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (03) : 207 - 218
  • [7] FROST HM, 1994, ANGLE ORTHOD, V64, P175
  • [8] Clinical complications of osseointegrated implants
    Goodacre, CJ
    Kan, JYK
    Rungcharassaeng, K
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (05) : 537 - 552
  • [9] THRESHOLD OF TACTILE SENSITIVITY PERCEIVED WITH DENTAL ENDOSSEOUS IMPLANTS AND NATURAL TEETH
    HAMMERLE, CHF
    WAGNER, D
    BRAGGER, U
    LUSSI, A
    KARAYIANNIS, A
    JOSS, A
    LANG, NP
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 1995, 6 (02) : 83 - 90
  • [10] FUNCTIONAL-STATE, BITE FORCE AND POSTURAL MUSCLE-ACTIVITY IN PATIENTS WITH OSSEOINTEGRATED ORAL IMPLANT BRIDGES
    HARALDSON, T
    CARLSSON, GE
    INGERVALL, B
    [J]. ACTA ODONTOLOGICA SCANDINAVICA, 1979, 37 (04) : 195 - 206