Three-dimensional finite element stress analysis of a cuneiform-geometry implant

被引:1
作者
Cruz, M
Wassall, T
Toledo, EM
Barra, LPD
Lemonge, ACD
机构
[1] Clin Ctr Res Stomatol, BR-36016901 Juiz De Fora, MG, Brazil
[2] Univ Camilo Castelo Branco, Dept Postgrad Dent, Campinas, SP, Brazil
[3] Natl Lab Sci Comp, Petropolis, RJ, Brazil
[4] Univ Fed Juiz de Fora, Sch Engn, Juiz De Fora, MG, Brazil
关键词
biomechanics; dental implants; dental stress analysis; finite element analysis;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The biomechanical behavior of an osseointegrated dental implant plays an important role in its functional longevity inside the bone. Studies of this aspect of dental implants by the finite element method are ongoing. In the present study, a cuneiform-geometry implant was considered with a 3-dimensional model that had a mesh that was finer than in the models commonly found in the literature. Materials and Methods: A mechanical model of an edentulous mandible was generated from computerized tomography, with the implant placed in the left first premolar region. A 100-N axial load was applied at the implant abutment, and the mandibular boundary conditions were modeled considering the real geometry of its muscle supporting system. The cortical and trabecular bone was assumed to be homogeneous, isotropic, and linearly elastic. Results: The stress analysis provided results that were used to plot global and detailed graphics of normal maximum (S1), minimum (S3), and von Mises stress fields. The results obtained were analyzed and compared qualitatively with the literature. Discussion: Quantitative comparisons were not performed because of basic differences between the model adopted here and those used by other authors. The stress distribution pattern for the studied geometry was similar to those found in the current literature, but insignificant apical stress concentration occurred. The stress concentration occurred at the neck of the implant, ie, in the cortical bone, which was similar to results for other implant shapes reported in the literature. Conclusion: The studied geometry showed a smooth stress pattern, with stress concentrated in the cervical region. The values, however, were within the range of values found in the cortical layer far from the implant, caused by the muscular action. No significant stress concentration was found in the apical area. (More than 50 references).
引用
收藏
页码:675 / 684
页数:10
相关论文
共 70 条
[1]  
Abdel-Latif HH, 2000, INT J PROSTHODONT, V13, P513
[2]  
Abu-Hammad OA, 2000, INT J ORAL MAX IMPL, V15, P559
[3]  
ADAMS VK, 1985, THESIS OHIO STATE U
[4]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[5]  
Akpinar I, 1996, Quintessence Int, V27, P11
[6]   BONE-METAL INTERFACE IN OSSEOINTEGRATION [J].
ALBREKTSSON, T ;
JACOBSSON, M .
JOURNAL OF PROSTHETIC DENTISTRY, 1987, 57 (05) :597-607
[7]  
Baiamonte T, 1996, J Oral Implantol, V22, P104
[8]  
BAUER A, 1976, GNATHOLOGY, P25
[9]  
BIDEZ MW, 1993, CONT IMPLANT DENT, P279
[10]   3-DIMENSIONAL STRESS-DISTRIBUTION AROUND A DENTAL IMPLANT AT DIFFERENT STAGES OF INTERFACE DEVELOPMENT [J].
BORCHERS, L ;
REICHART, P .
JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) :155-159