In this paper, thermoeconomic optimization and exergy analysis are applied to a CO2/NH3 cascade refrigeration cycle. Cooling capacity, ambient temperature and cold space temperature are constraints of the optimization procedure. Four parameters including condensing temperature of ammonia, evaporating temperature of carbon dioxide, condensing temperature of carbon dioxide and temperature difference in the cascade condenser are chosen as decision variables. The objective function is the total annual cost of the system which includes costs of input exergy to the system and annualized capital cost of the system. Input exergy to the system is the electricity consumption of compressors and fans, and the capital cost includes purchase costs of components. Results show that, optimum values of decision variables may be found by trade-off between the input exergy cost and capital cost. Results of the exergy analysis for each of the system components in the optimum state are also given. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:888 / 895
页数:8
相关论文
共 22 条
[1]  
[Anonymous], IND REFRIGERATION HD
[2]  
Bejan A., 2003, Heat transfer handbook, V1
[3]  
Bejan A, 1996, THERMAL DESIGN OPTIM
[4]   Optimization of a CO2-C3H8 cascade system for refrigeration and heating [J].
Bhattacharyya, S ;
Mukhopadhyay, S ;
Kumar, A ;
Khurana, RK ;
Sarkar, J .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1284-1292
[5]   Exergy maximization of cascade refrigeration cycles and its numerical verification for a transcritical CO2-C3H8 system [J].
Bhattacharyya, Souvik ;
Bose, S. ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (04) :624-632
[6]  
Dingeç H, 1999, INT J ENERG RES, V23, P949, DOI 10.1002/(SICI)1099-114X(199909)23:11<949::AID-ER531>3.0.CO
[7]  
2-A
[8]   Thermodynamic analysis of an R744-R717 cascade refrigeration system [J].
Getu, H. M. ;
Bansal, P. K. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (01) :45-54
[9]  
Kakac S., 2002, HEAT EXCHANGERS SELE
[10]  
Kays W.M., 1984, COMPACT HEAT EXCHANG, V3rd