Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:13
|
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 50 条
  • [41] High-Resolution 3D versus Standard-Resolution 2D T2-Weighted Turbo Spin Echo MRI for the Assessment of Lumbar Nerve Root Compromise
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    Schwenk, Arpad
    Alfieri, Alex
    Czell, David
    Wyss, Michael
    Wildi, Lukas
    Binkert, Christoph A.
    Sartoretti-Schefer, Sabine
    TOMOGRAPHY, 2022, 8 (01) : 257 - 266
  • [42] MRI evaluation of soft tissue tumors: comparison of a fast, isotropic, 3D T2-weighted fat-saturated sequence with a conventional 2D T2-weighted fat-saturated sequence for tumor characteristics, resolution, and acquisition time
    de Castro Luna, Rodrigo
    Kumar, Neil M.
    Fritz, Jan
    Ahlawat, Shivani
    Fayad, Laura M.
    EUROPEAN RADIOLOGY, 2022, 32 (12) : 8670 - 8680
  • [43] MRI of the Neck at 3 Tesla Using the Periodically Rotated Overlapping Parallel Lines with Enhanced Reconstruction (PROPELLER) (BLADE) Sequence Compared with T2-Weighted Fast Spin-Echo Sequence
    Ohgiya, Yoshimitsu
    Suyama, Jumpei
    Seino, Noritaka
    Takaya, Shu
    Kawahara, Masaaki
    Saiki, Makoto
    Sai, Syouei
    Hirose, Masanori
    Gokan, Takehiko
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) : 1061 - 1067
  • [44] 3D T2-weighted turbo spin-echo MR sequence for identifying cerebrospinal fluid leak after endoscopic endonasal pituitary surgery
    Chung, Sang-Bong
    Kwag, Kyung-Su
    Kim, Sung Tae
    Park, Kwan
    Kim, Jong Hyun
    Kong, Doo-Sik
    ACTA NEUROCHIRURGICA, 2012, 154 (08) : 1499 - 1503
  • [45] 3D T2-weighted turbo spin-echo MR sequence for identifying cerebrospinal fluid leak after endoscopic endonasal pituitary surgery
    Sang-Bong Chung
    Kyung-Su Kwag
    Sung Tae Kim
    Kwan Park
    Jong Hyun Kim
    Doo-Sik Kong
    Acta Neurochirurgica, 2012, 154 : 1499 - 1503
  • [46] Uterine cervical carcinoma: a comparison of two- and three-dimensional T2-weighted turbo spin-echo MR imaging at 3.0 T for image quality and local-regional staging
    Shin, Y. R.
    Rha, S. E.
    Choi, B. G.
    Oh, S. N.
    Park, M. Y.
    Byun, J. Y.
    EUROPEAN RADIOLOGY, 2013, 23 (04) : 1150 - 1157
  • [47] Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study
    Hussain, SM
    De Becker, J
    Hop, WCJ
    Dwarkasing, S
    Wielopolski, PA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (03) : 219 - 229
  • [48] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [49] Diagnosis of Nerve Root Compromise of the Lumbar Spine: Evaluation of the Performance of Three-dimensional Isotropic T2-weighted Turbo Spin-Echo SPACE Sequence at 3T
    Sung, Jinkyeong
    Jee, Won-Hee
    Jung, Joon-Yong
    Jang, Jinhee
    Kim, Jin-Sung
    Kim, Young-Hoon
    Ha, Kee-Yong
    KOREAN JOURNAL OF RADIOLOGY, 2017, 18 (01) : 249 - 259
  • [50] MRI of the uterus, uterine cervix, and vagina: diagnostic performance of dynamic contrast-enhanced fast multiplanar gradient-echo imaging in comparison with fast spin echo T2-weighted pulse imaging
    Liu, PF
    Krestin, GP
    Huch, RA
    Gohde, SC
    Caduff, RF
    Debatin, JF
    EUROPEAN RADIOLOGY, 1998, 8 (08) : 1433 - 1440