Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:13
|
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 50 条
  • [1] Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis
    Takahiro Tsuboyama
    Oki Takei
    Atsuhiko Okada
    Toru Honda
    Keiko Kuriyama
    European Radiology, 2020, 30 : 3245 - 3253
  • [2] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [3] Comparison between turbo spin-echo and echo planar diffusion-weighted imaging of the female pelvis with 3T MRI
    Yoshizako, Takeshi
    Yoshida, Rika
    Asou, Hiroya
    Nakamura, Megumi
    Kitagaki, Hajime
    ACTA RADIOLOGICA OPEN, 2021, 10 (02)
  • [4] Comparison of a deep learning-accelerated T2-weighted turbo spin echo sequence and its conventional counterpart for female pelvic MRI: reduced acquisition times and improved image quality
    Ren, Jing
    Li, Yuan
    Liu, Fei-Shi
    Liu, Chong
    Zhu, Jin-Xia
    Nickel, Marcel Dominik
    Wang, Xiao-Ye
    Liu, Xin-Yu
    Zhao, Jia
    He, Yong-Lan
    Jin, Zheng-Yu
    Xue, Hua-Dan
    INSIGHTS INTO IMAGING, 2022, 13 (01)
  • [5] Comparison of a deep learning-accelerated T2-weighted turbo spin echo sequence and its conventional counterpart for female pelvic MRI: reduced acquisition times and improved image quality
    Jing Ren
    Yuan Li
    Fei-Shi Liu
    Chong Liu
    Jin-Xia Zhu
    Marcel Dominik Nickel
    Xiao-Ye Wang
    Xin-Yu Liu
    Jia Zhao
    Yong-Lan He
    Zheng-Yu Jin
    Hua-Dan Xue
    Insights into Imaging, 13
  • [6] Semicircular canal dehiscence: comparison of T2-weighted turbo spin-echo MRI and CT
    G. A. Krombach
    T. Schmitz-Rode
    P. Haage
    E. DiMartino
    A. Prescher
    S. Kinzel
    R. W. Günther
    Neuroradiology, 2004, 46 : 326 - 331
  • [7] Semicircular canal dehiscence:: comparison of T2-weighted turbo spin-echo MRI and CT
    Krombach, GA
    Schmitz-Rode, T
    Haage, P
    DiMartino, E
    Prescher, A
    Kinzel, S
    Günther, RW
    NEURORADIOLOGY, 2004, 46 (04) : 326 - 331
  • [8] Utility of accelerated T2-weighted turbo spin-echo imaging with deep learning reconstruction in female pelvic MRI: a multi-reader study
    Eun Ji Lee
    Jiyoung Hwang
    Suyeon Park
    Sung Hwan Bae
    Jiyun Lim
    Yun-Woo Chang
    Seong Sook Hong
    Eunsun Oh
    Bo Da Nam
    Jewon Jeong
    Jae Kon Sung
    Dominik Nickel
    European Radiology, 2023, 33 : 7697 - 7706
  • [9] Utility of accelerated T2-weighted turbo spin-echo imaging with deep learning reconstruction in female pelvic MRI: a multi-reader study
    Lee, Eun Ji
    Hwang, Jiyoung
    Park, Suyeon
    Bae, Sung Hwan
    Lim, Jiyun
    Chang, Yun-Woo
    Hong, Seong Sook
    Oh, Eunsun
    Nam, Bo Da
    Jeong, Jewon
    Sung, Jae Kon
    Nickel, Dominik
    EUROPEAN RADIOLOGY, 2023, 33 (11) : 7697 - 7706
  • [10] Comparison of Sagittal T2-Weighted BLADE and Fast Spin-Echo MRI of the Female Pelvis for Motion Artifact and Lesion Detection
    Lane, Barton F.
    Vandermeer, Fauzia Q.
    Oz, Rasim C.
    Irwin, Eric W.
    McMillan, Alan B.
    Wong-You-Cheong, Jade J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : W307 - W313