Comparison of HASTE with multiple signal averaging versus conventional turbo spin echo sequence: a new option for T2-weighted MRI of the female pelvis

被引:15
作者
Tsuboyama, Takahiro [1 ]
Takei, Oki [1 ]
Okada, Atsuhiko [1 ]
Honda, Toru [1 ]
Kuriyama, Keiko [1 ]
机构
[1] Natl Hosp Org Osaka Natl Hosp, Dept Radiol, Chuo Ku, 2-1-14 Hoenzaka, Osaka 5400006, Japan
关键词
Magnetic resonance imaging; Spin echo imaging; Pelvis; Female; IMAGE QUALITY; INCREASED SPEED; ACQUISITION; BLADE; 3D;
D O I
10.1007/s00330-020-06686-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives This study was conducted in order to evaluate the feasibility of a newly developed half-Fourier acquisition single-shot turbo spin echo (HASTE) sequence for T2-weighted MRI of the female pelvis, in which scanning and post-processing filtering techniques were optimized to minimize blurring and the resultant reduction in signal-to-noise ratio (SNR) was compensated by signal averaging of multiple excitations (multi-NEX), and to compare its image quality with that of a conventional turbo spin echo (TSE) sequence. Methods Fifty females with gynecological disease were prospectively enrolled. They underwent pelvic MRI including sagittal T2-weighted imaging obtained with multi-NEX HASTE (mHASTE) and TSE with acquisition times of 1 m 9 s and 3 m 26 s, respectively. At the prospective reading, mHASTE was reviewed first, and any changes in the image interpretation detected during the subsequent TSE reading were recorded. The SNR and tissue contrast were quantitatively measured. Two radiologists independently assessed tissue conspicuity and overall image quality considering noise, artifacts, and blurring, and visual grading characteristics (VGC) analysis was performed to compare the two sequences. Results Adding TSE to mHASTE did not change image interpretations in any case. mHASTE produced an equivalent SNR and significantly higher contrast between the myometrium and junctional zone (p < 0.05) compared with TSE. The area under the VGC curve (AUC(VGC)) showed that the conspicuity of the uterus, ovaries, and lesions and the overall image quality were significantly higher on mHASTE than on TSE for both readers (AUC(VGC), 0.740-0.880; p < 0.01). Conclusion mHASTE is a feasible option for T2-weighted MRI of the female pelvis, as it allows faster and higher-quality image acquisition than conventional TSE.
引用
收藏
页码:3245 / 3253
页数:9
相关论文
共 24 条
[1]   Visual grading characteristics (VGC) analysis:: a non-parametric rank-invariant statistical method for image quality evaluation [J].
Bath, M. ;
Mansson, L. G. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (951) :169-176
[2]   Fetal magnetic resonance imaging: indications, technique, anatomical considerations and a review of fetal abnormalities [J].
Ertl-Wagner, B ;
Lienemann, A ;
Strauss, A ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2002, 12 (08) :1931-1940
[3]   BLADE acquisition method improves T2-weighted MR images of the female pelvis compared with a standard fast spin-echo sequence [J].
Fujimoto, Koji ;
Koyama, Takashi ;
Tamai, Ken ;
Morisawa, Nobuko ;
Okada, Tomohisa ;
Togashi, Kaori .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) :796-801
[4]   T2-weighted MR imaging of the uterus: Comparison of optimized fast spin-echo and HASTE sequences with conventional fast spin-echo sequences [J].
Gryspeerdt, S ;
Van Hoe, L ;
Bosmans, H ;
Baert, AL ;
Vergote, I ;
Marchal, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (01) :211-215
[5]   Half-Fourier-Acquisition Single-Shot Turbo Spin-Echo (HASTE) MRI of the Lung at 3 Tesla Using Parallel Imaging With 32-Receiver Channel Technology [J].
Henzler, Thomas ;
Dietrich, Olaf ;
Krissak, Radko ;
Wichmann, Tobias ;
Lanz, Titus ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. ;
Fink, Christian .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) :541-546
[6]   Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T-Initial Experience [J].
Hori, Masatoshi ;
Kim, Tonsok ;
Onishi, Hiromitsu ;
Ueguchi, Takashi ;
Tatsumi, Mitsuaki ;
Nakamoto, Atsushi ;
Tsuboyama, Takahiro ;
Tomoda, Kaname ;
Tomiyama, Noriyuki .
RADIOLOGY, 2011, 258 (01) :154-163
[7]   Developing an MR imaging strategy for diagnosis of ovarian masses [J].
Imaoka, Izumi ;
Wada, Akihiko ;
Kaji, Yasushi ;
Hayashi, Takafumi ;
Hayashi, Michiharu ;
Matsuo, Michimasa ;
Sugimura, Kazuro .
RADIOGRAPHICS, 2006, 26 (05) :1431-1448
[8]   MRI of Placenta Accreta, Placenta Increta, and Placenta Percreta: Pearls and Pitfalls [J].
Kilcoyne, Aoife ;
Shenoy-Bhangle, Anuradha S. ;
Roberts, Drucilla J. ;
Sisodia, Rachel Clark ;
Gervais, Debra A. ;
Lee, Susanna I. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (01) :214-221
[9]   European Society of Urogenital Radiology (ESUR) Guidelines: MR Imaging of Leiomyomas [J].
Kubik-Huch, Rahel A. ;
Weston, Michael ;
Nougaret, Stephanie ;
Leonhardt, Henrik ;
Thomassin-Naggara, Isabelle ;
Horta, Mariana ;
Cunha, Teresa Margarida ;
Maciel, Cristina ;
Rockall, Andrea ;
Forstner, Rosemarie .
EUROPEAN RADIOLOGY, 2018, 28 (08) :3125-3137
[10]   Comparison of Sagittal T2-Weighted BLADE and Fast Spin-Echo MRI of the Female Pelvis for Motion Artifact and Lesion Detection [J].
Lane, Barton F. ;
Vandermeer, Fauzia Q. ;
Oz, Rasim C. ;
Irwin, Eric W. ;
McMillan, Alan B. ;
Wong-You-Cheong, Jade J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) :W307-W313