Radiation Exposure of the Anesthesiologist in the Neurointerventional Suite

被引:39
作者
Anastasian, Zirka H. [1 ]
Strozyk, Dorothea [2 ]
Meyers, Philip M. [3 ,4 ]
Wang, Shuang [5 ]
Berman, Mitchell F. [1 ]
机构
[1] Columbia Univ Coll Phys & Surg, Dept Anesthesiol, New York, NY 10032 USA
[2] Neurosurg Associates New Jersey, Intervent Vasc Neurol, Ridgewood, NJ USA
[3] Columbia Univ Coll Phys & Surg, Dept Neurol Surg, New York, NY 10032 USA
[4] Columbia Univ Coll Phys & Surg, Dept Radiol, New York, NY 10032 USA
[5] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, New York, NY USA
关键词
D O I
10.1097/ALN.0b013e31820c2b81
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Scatter radiation during interventional radiology procedures can produce cataracts in participating medical personnel. Standard safety equipment for the radiologist includes eye protection. The typical configuration of fluoroscopy equipment directs radiation scatter away from the radiologist and toward the anesthesiologist. This study analyzed facial radiation exposure of the anesthesiologist during interventional neuroradiology procedures. Methods: Radiation exposure to the forehead of the anesthesiologist and radiologist was measured during 31 adult neuroradiologic procedures involving the head or neck. Variables hypothesized to affect anesthesiologist exposure wererecorded for each procedure. These included total radiation emitted by fluoroscopic equipment, radiologist exposure, number of pharmacologic interventions performed by the anesthesiologist, and other variables. Results: Radiation exposure to the anesthesiologist's face averaged 6.5 +/- 5.4 mu Sv per interventional procedure. This exposure was more than 6-fold greater (P < 0.0005) than for noninterventional angiographic procedures (1.0 +/- 1.0) and averaged more than 3-fold the exposure of the radiologist (ratio, 3.2; 95% CI, 1.8-4.5). Multiple linear regression analysis showed that the exposure of the anesthesiologist was correlated with the number of pharmacologic interventions performed by the anesthesiologist and the total exposure of the radiologist. Conclusions: Current guidelines for occupational radiation exposure to the eye are undergoing review and are likely to be lowered below the current 100-150 mSv/yr limit. Anesthesiologists who spend significant time in neurointerventional radiology suites may have ocular radiation exposure approaching that of a radiologist. To ensure parity with safety standards adopted by radiologists, these anesthesiologists should wear protective eyewear.
引用
收藏
页码:512 / 520
页数:9
相关论文
共 31 条
  • [1] Radiation Cataractogenesis: A Review of Recent Studies
    Ainsbury, E. A.
    Bouffler, S. D.
    Doerr, W.
    Graw, J.
    Muirhead, C. R.
    Edwards, A. A.
    Cooper, J.
    [J]. RADIATION RESEARCH, 2009, 172 (01) : 1 - 9
  • [2] Patient radiation exposure during diagnostic and therapeutic interventional neuroradiology procedures
    Alexander, M. D.
    Oliff, M. C.
    Olorunsola, O. G.
    Brus-Ramer, M.
    Nickoloff, E. L.
    Meyers, P. M.
    [J]. JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2010, 2 (01) : 6 - 10
  • [3] [Anonymous], 2006, POLICY BRIEF, P1
  • [4] 100 years of observation on British radiologists: mortality from cancer and other causes 1897-1997
    Berrington, A
    Darby, SC
    Weiss, HA
    Doll, R
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (882) : 507 - 519
  • [5] OPTIMAL RESOURCES FOR THE EXAMINATION AND ENDOVASCULAR TREATMENT OF THE PERIPHERAL AND VISCERAL VASCULAR SYSTEMS - AHA INTERCOUNCIL REPORT ON PERIPHERAL AND VISCERAL ANGIOGRAPHIC AND INTERVENTIONAL LABORATORIES
    CARDELLA, JF
    CASARELLA, WJ
    DEWEESE, JA
    DORROS, GM
    GRAY, JE
    KATZEN, BT
    LARAGH, JH
    LEVIN, DC
    MARX, VM
    NICKOLOFF, EL
    PENTECOST, MJ
    ROUBIN, GS
    MARTIN, EC
    [J]. CIRCULATION, 1994, 89 (03) : 1481 - 1493
  • [6] CHATTERJEE S, 2006, VARIABLE SELECTION P, P281
  • [7] Chatterjee S., 2015, Regression Analysis by Example, P85, DOI [10.1002/0470055464.ch4, DOI 10.1002/0470055464.CH4]
  • [8] THE CASE FOR RADIOPROTECTIVE EYEWEAR FACEWEAR - PRACTICAL IMPLICATIONS AND SUGGESTIONS
    COUSIN, AJ
    LAWDAHL, RB
    CHAKRABORTY, DP
    KOEHLER, RE
    [J]. INVESTIGATIVE RADIOLOGY, 1987, 22 (08) : 688 - 692
  • [9] HALL EJ, 2000, RAD PROTECTION RADIO, P234
  • [10] HALL EJ, 2000, GLOSSARY RADIOBIOLOG, P521