Temperature-dependent near-infrared spectra of bovine serum albumin in aqueous solutions: Spectral analysis by principal component analysis and evolving factor analysis

被引:43
|
作者
Yuan, B
Murayama, K
Wu, YQ
Tsenkova, R
Dou, XM
Era, S
Ozaki, Y [1 ]
机构
[1] Kwansei Gakuin Univ, Sch Sci & Technol, Dept Chem, Sanda, Hyogo 6691337, Japan
[2] Kwansei Gakuin Univ, Sch Sci & Technol, Res Ctr Near Infrared Spect, Sanda, Hyogo 6691337, Japan
[3] Shanghai Jiao Tong Univ, Dept Phys, Mol Photon Lab, Shanghai 200240, Peoples R China
[4] Gifu Univ, Sch Med, Dept Prot Sci & Struct Biol, Gifu 5008705, Japan
[5] Jilin Univ, Key Lab Supramol Struct & Mat, Changchun 130023, Peoples R China
[6] Kobe Univ, Fac Agr, Higashinada Ku, Kobe, Hyogo 6578501, Japan
关键词
serum albumin; near-infrared spectroscopy; NIR; principal component analysis; PCA; evolving factor analysis; hydration; protein;
D O I
10.1366/000370203769699072
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fourier transform near-infrared (FT-NIR) spectra have been measured for bovine serum albumin (BSA) in an aqueous solution (pH 6.8) with a concentration of 5.0 wt % over a temperature range of 45-85 degreesC. Not only conventional spectral analysis methods, such as second-derivative spectra and difference spectra, but also chemometrics, such as principal component analysis (PCA) and evolving factor analysis (EFA), have been employed to analyze the temperature-dependent NIR spectra in the 7500-5500 and 4900-4200 cm(-1) regions of the BSA aqueous solution. Intensity changes of bands in the 7200-6600 cm(-1) and 4650-4500 cm(-1) regions in the difference spectra indicate variations of the hydration and secondary structure of BSA in the aqueous solution, respectively. The plot of a band intensity at 7080 cm(-1) in the different spectra shows a clear turning point at 63 degreesC, revealing that a significant change in the hydration occurs at about degrees63 C. The forward and backward eigenvalues (EVs) from EFA suggest that marked changes in the hydration and secondary structure of BSA take place in the temperature ranges of 61-65 degreesC and 59-63 degreesC, respectively. In addition, the temperature of 71 degreesC marked in the EFA plots may correspond to the onset temperature of increase in the intermolecular beta-sheet structure.
引用
收藏
页码:1223 / 1229
页数:7
相关论文
共 49 条
  • [11] Band analysis of temperature-dependent near-infrared spectra of oleic acid in the pure liquid state by the analytic geometric approach
    Koashi, K
    Iwahashi, M
    Ozaki, Y
    APPLIED SPECTROSCOPY, 2003, 57 (12) : 1539 - 1550
  • [12] Spectral reflectance measurement and the principal component analysis and correlation analysis of trees in visible and near infrared
    Du, Zhenhua
    Shi, Junsheng
    Cheng, Feiyan
    Huang, Xiaoqiao
    Xu, Lin
    INFRARED, MILLIMETER-WAVE, AND TERAHERTZ TECHNOLOGIES V, 2018, 10826
  • [13] Principal component analysis of visible and near-infrared multispectral images of works of art
    Baronti, S
    Casini, A
    Lotti, F
    Porcinai, S
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1997, 39 (01) : 103 - 114
  • [14] Resolving Near-Infrared Spectra by Generalized Window Factor Analysis for Understanding Interactions in Aqueous Solution
    Wang, Mian
    Cai, Wensheng
    Shao, Xueguang
    ANALYTICAL LETTERS, 2023, 56 (14) : 2226 - 2236
  • [15] Analysis of hydration water around human serum albumin using near-infrared spectroscopy
    Dong, Qin
    Yu, Chen
    Li, Lian
    Nie, Lei
    Zhang, Hui
    Zang, Hengchang
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2019, 138 : 927 - 932
  • [16] Principal component analysis-support vector regression and its application in near infrared spectral analysis
    Hou Zhenyu
    Cai Wensheng
    Shao Xueguang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (05) : 617 - 620
  • [17] Comparison between conventional spectral analysis methods, chemometrics, and two-dimensional correlation spectroscopy in the analysis of near-infrared spectra of protein
    Murayama, K
    Czarnik-Matusewicz, B
    Wu, YQ
    Tsenkova, R
    Ozaki, Y
    APPLIED SPECTROSCOPY, 2000, 54 (07) : 978 - 985
  • [18] Application of principal component analysis in calibration sample selection of near-infrared quantitative model
    Li Yan-Zhou
    Min Shun-Geng
    Liu Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (09) : 1331 - 1334
  • [19] SELECTION OF NEAR-INFRARED WAVELENGTHS FOR MONITORING MILK COAGULATION USING PRINCIPAL COMPONENT ANALYSIS
    SAPUTRA, D
    PAYNE, FA
    LODDER, RA
    SHEARER, SA
    TRANSACTIONS OF THE ASAE, 1992, 35 (05): : 1597 - 1605
  • [20] Comparison of principal and independent component analysis in removing extracerebral interference from near-infrared spectroscopy signals
    Virtanen, Jaakko
    Noponen, Tommi
    Merilainen, Pekka
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)