Evaluation of Common Theoretical Methods for Predicting Infrared Multiphotonic Dissociation Vibrational Spectra of Intramolecular Hydrogen-Bonded Ions

被引:48
作者
Rodrigues-Oliveira, Andre F. [1 ]
Ribeiro, Francisco W. M. [1 ]
Cervi, Gustavo [1 ]
Correra, Thiago C. [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, Dept Fundamental Chem, Ave Prof Lineu Prestes 748, BR-05508000 Sao Paulo, Brazil
来源
ACS OMEGA | 2018年 / 3卷 / 08期
基金
巴西圣保罗研究基金会;
关键词
DENSITY-FUNCTIONAL THEORY; FREE-ELECTRON-LASER; MASS-SPECTROMETRY; STRUCTURAL-CHARACTERIZATION; SCALING FACTORS; AMINO-ACIDS; HYBRID META; SPECTROSCOPY; THERMOCHEMISTRY; DFT;
D O I
10.1021/acsomega.8b00815
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Infrared photodissociation analyses are supported by theoretical calculations that allow a trustworthy interpretation of experimental spectra of gaseous ions. B3LYP calculations are the most prominent method used to model IR spectra, as detailed in our bibliographic survey. However, this and other commonly used methods are known to provide inaccurate energy values and geometries, especially when it comes to long-range linteractions, such as intramolecular H-bonds, which show increased anharmorucity. Therefore, we evaluated some of the most commonly used density functional theory methods (B3LYP, CAM-B3LYP, and M06-2X) and basis sets (6-31+G(d,p), 6-311++G(d,p), 6-311++G(3df,2pd), aug-cc-pVDZ, and aug-cc-pVTZ), including anharmonicity and dispersion corrections. The results were compared to MP2 calculations and to experimental high-frequency (2000-4000 cm(-1)) IR multiphotonic dissociation (IRMPD) spectra of two protonated model molecules containing intramolecular hydrogen bonds: biotin and tryptophan. M06-2X/6-31+G(d,p) was shown to be the most cost-effective level of theory, whereas CAM B3LYP was the most efficient method to describe the van der Waals interactions. The use of the dispersion correction D3, proposed by Grimmer improved the descnpfion of O-H vibrations involved in H-bonding but worsened the description of N-H stretches. Anharmonic calculations were shown to be extremely expensive when compared to other approaches. The efficiencies of well-established scaling factors (SFs) in opposition to sample-dependent SFs were also discussed and the use of fitted SFs were shown to be the most cost-effective approach to predict IRMPD spectra. M06-2X/6-31+G(d,p) and CAM-B3LYP/aug-cc-pVDZ were also tested against the fingerprint region. Our results suggest that these methods can also be used for analysis in this lower frequency range and should be regarded as the methods of choice for cost-effective IRMPD simulations rather than the ubiquitous B3LYP method, especially when further molecular properties are needed.
引用
收藏
页码:9075 / 9085
页数:11
相关论文
共 68 条
  • [1] Application of enhanced gas chromatography/triple quadrupole mass spectrometry for monitoring petroleum weathering and forensic source fingerprinting in samples impacted by the Deepwater Horizon oil spill
    Adhikari, Puspa L.
    Wong, Roberto L.
    Overton, Edward B.
    [J]. CHEMOSPHERE, 2017, 184 : 939 - 950
  • [2] Computational Thermochemistry: Scale Factor Databases and Scale Factors for Vibrational Frequencies Obtained from Electronic Model Chemistries
    Alecu, I. M.
    Zheng, Jingjing
    Zhao, Yan
    Truhlar, Donald G.
    [J]. JOURNAL OF CHEMICAL THEORY AND COMPUTATION, 2010, 6 (09) : 2872 - 2887
  • [3] DENSITY-FUNCTIONAL THERMOCHEMISTRY .3. THE ROLE OF EXACT EXCHANGE
    BECKE, AD
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1993, 98 (07) : 5648 - 5652
  • [4] Extrapolation of water and formaldehyde harmonic and anharmonic frequencies to the B3LYP/CBS limit using polarization consistent basis sets
    Buczek, Aneta
    Kupka, Teobald
    Broda, Malgorzata A.
    [J]. JOURNAL OF MOLECULAR MODELING, 2011, 17 (08) : 2029 - 2040
  • [5] Monitoring of chemical transformations by mass spectrometry
    Chen, Chun-Chi
    Lin, Po-Chiao
    [J]. ANALYTICAL METHODS, 2015, 7 (17) : 6947 - 6959
  • [6] Making Mass Spectrometry See the Light: The Promises and Challenges of Cryogenic Infrared Ion Spectroscopy as a Bioanalytical Technique
    Cismesia, Adam P.
    Bailey, Laura S.
    Bell, Matthew R.
    Tesler, Larry F.
    Polfer, Nicolas C.
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (05) : 757 - 766
  • [7] Versatile new ion source for the analysis of materials in open air under ambient conditions
    Cody, RB
    Laramée, JA
    Durst, HD
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (08) : 2297 - 2302
  • [8] Insights into current limitations of density functional theory
    Cohen, Aron J.
    Mori-Sanchez, Paula
    Yang, Weitao
    [J]. SCIENCE, 2008, 321 (5890) : 792 - 794
  • [9] Sequential Methyl-Fluorine Exchange Reactions of Siloxide Ions in the Gas Phase
    Correra, Thiago C.
    Riveros, Jose M.
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (34) : 8632 - 8635
  • [10] Assessing the performance of computational methods for the prediction of the ground state structure of a cyclic decapeptide
    Doemer, Manuel
    Guglielmi, Matteo
    Athri, Prashanth
    Nagornova, Natalia S.
    Rizzo, Thomas R.
    Boyarkin, Oleg V.
    Tavernelli, Ivano
    Rothlisberger, Ursula
    [J]. INTERNATIONAL JOURNAL OF QUANTUM CHEMISTRY, 2013, 113 (06) : 808 - 814