High-resolution fast-tomography brain-imaging beamline at the Taiwan Photon Source

被引:8
作者
Chen, Hsiang Hsin [1 ]
Yang, Shun-Min [1 ]
Yang, Kai-En [1 ]
Chiu, Ching-Yu [1 ]
Chang, Chia-Ju [1 ]
Wang, Ya-Sian [1 ]
Lee, Tsung-Tse [1 ]
Huang, Yu-Fen [1 ]
Chen, Yi-Yun [1 ]
Petibois, Cyril [1 ]
Chang, Shih-Hung [2 ]
Cai, Xiaoqing [3 ]
Low, Chian-Ming [4 ,5 ]
Tan, Francis Chee Kuan [5 ]
Teo, Alvin [6 ]
Tok, Eng Soon [7 ]
Lim, Jae-Hong [8 ]
Je, Jun-Ho [9 ]
Kohmura, Yoshiki [10 ]
Ishikawa, Tetsuya [10 ]
Margaritondo, Giorgio [11 ,12 ,13 ]
Hwu, Yeukuang [1 ]
机构
[1] Acad Sinica, Inst Phys, 128 Acad Rd Sec 2, Taipei 11529, Taiwan
[2] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
[3] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai, Peoples R China
[4] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Pharmacol, Singapore, Singapore
[5] Natl Univ Hlth Syst, Natl Univ Hosp, Dept Anaesthesia, Singapore, Singapore
[6] Nanyang Polytech, Sch Chem & Life Sci, Singapore, Singapore
[7] Natl Univ Singapore, Dept Phys, eMaGIC Lab, Singapore, Singapore
[8] Pohang Univ Sci & Technol, Pohang Accelerator Lab, Pohang 37673, Gyeongbuk, South Korea
[9] Pohang Univ Sci & Technol, Dept Mat Sci & Engn, Pohang 37673, Gyeongbuk, South Korea
[10] RIKEN SPring 8 Ctr, Sayo, Hyogo 6795148, Japan
[11] Ecole Polytech Fed Lausanne, Fac Sci Base, CH-1015 Lausanne, Switzerland
[12] Natl Tsing Hua Univ, Brain Res Ctr, Hsinchu 30013, Taiwan
[13] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 70100, Taiwan
关键词
microtomography; high-resolution X-ray imaging; brain imaging; SYNCHROTRON-RADIATION; RAY; SHADOW;
D O I
10.1107/S1600577521007633
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new Brain Imaging Beamline (BIB) of the Taiwan Photon Source (TPS) has been commissioned and opened to users. The BIB and in particular its endstation are designed to take advantage of bright unmonochromatized synchrotron X-rays and target fast 3D imaging, similar to 1 ms exposure time plus very high similar to 0.3 mu m spatial resolution. A critical step in achieving the planned performances was the solution to the X-ray induced damaging problems of the detection system. High-energy photons were identified as their principal cause and were solved by combining tailored filters/attenuators and a high-energy cut-off mirror. This enabled the tomography acquisition throughput to reach >1 mm(3) min(-1), a critical performance for large-animal brain mapping and a vital mission of the beamline.
引用
收藏
页码:1662 / 1668
页数:7
相关论文
共 37 条
[21]   A kinetic interpretation of the coloring of glass by x-rays [J].
Livingston, R ;
Nurnberger, CE .
JOURNAL OF PHYSICAL CHEMISTRY, 1935, 39 (07) :1011-1019
[22]   High-speed rotating device for X-ray tomography with 10 ms temporal resolution [J].
Mashita, Ryo ;
Yashiro, Wataru ;
Kaneko, Daisuke ;
Bito, Yasumasa ;
Kishimoto, Hiroyuki .
JOURNAL OF SYNCHROTRON RADIATION, 2021, 28 :322-326
[23]   Following Dynamic Processes by X-ray Tomographic Microscopy with Sub-second Temporal Resolution [J].
Mokso, R. ;
Marone, F. ;
Haberthuer, D. ;
Schittny, J. C. ;
Mikuljan, G. ;
Isenegger, A. ;
Stampanoni, M. .
10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 :38-41
[24]   GigaFRoST: the gigabit fast readout system for tomography [J].
Mokso, Rajmund ;
Schlepuetz, Christian M. ;
Theidel, Gerd ;
Billich, Heiner ;
Schmid, Elmar ;
Celcer, Tine ;
Mikuljan, Gordan ;
Sala, Leonardo ;
Marone, Federica ;
Schlumpf, Nick ;
Stampanoni, Marco .
JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 :1250-1259
[25]   Design and performance of an X-ray scanning microscope at the Hard X-ray Nanoprobe beamline of NSLS-II [J].
Nazaretski, E. ;
Yan, H. ;
Lauer, K. ;
Bouet, N. ;
Huang, X. ;
Xu, W. ;
Zhou, J. ;
Shu, D. ;
Hwu, Y. ;
Chu, Y. S. .
JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 :1113-1119
[26]   Illuminating the Brain With X-Rays: Contributions and Future Perspectives of High-Resolution Microtomography to Neuroscience [J].
Rodrigues, Paulla Vieira ;
Tostes, Katiane ;
Bosque, Beatriz Pelegrini ;
Godoy, Joao Vitor Pereira de ;
Amorim Neto, Dionisio Pedro ;
Dias, Carlos Sato Baraldi ;
Fonseca, Matheus de Castro .
FRONTIERS IN NEUROSCIENCE, 2021, 15
[27]   Trends in synchrotron-based tomographic imaging:: the SLS experience [J].
Stampanoni, M. ;
Groso, A. ;
Isenegger, A. ;
Mikuljan, G. ;
Chen, Q. ;
Bertrand, A. ;
Henein, S. ;
Betemps, R. ;
Frommherz, U. ;
Boehler, P. ;
Meister, D. ;
Lange, M. ;
Abela, R. .
DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
[28]   SPECTRA: a synchrotron radiation calculation code [J].
Tanaka, T ;
Kitamura, H .
JOURNAL OF SYNCHROTRON RADIATION, 2001, 8 :1221-1228
[29]   Electrochemistry - Building on bubbles in metal electrodeposition [J].
Tsai, WL ;
Hsu, PC ;
Hwu, Y ;
Chen, CH ;
Chang, LW ;
Je, JH ;
Lin, HM ;
Groso, A ;
Margaritondo, G .
NATURE, 2002, 417 (6885) :139-139
[30]   Development of pink-beam 4D phase CT for in-situ observation of polymers under infrared laser irradiation [J].
Vegso, Karol ;
Wu, Yanlin ;
Takano, Hidekazu ;
Hoshino, Masato ;
Momose, Atsushi .
SCIENTIFIC REPORTS, 2019, 9