High-resolution fast-tomography brain-imaging beamline at the Taiwan Photon Source

被引:8
作者
Chen, Hsiang Hsin [1 ]
Yang, Shun-Min [1 ]
Yang, Kai-En [1 ]
Chiu, Ching-Yu [1 ]
Chang, Chia-Ju [1 ]
Wang, Ya-Sian [1 ]
Lee, Tsung-Tse [1 ]
Huang, Yu-Fen [1 ]
Chen, Yi-Yun [1 ]
Petibois, Cyril [1 ]
Chang, Shih-Hung [2 ]
Cai, Xiaoqing [3 ]
Low, Chian-Ming [4 ,5 ]
Tan, Francis Chee Kuan [5 ]
Teo, Alvin [6 ]
Tok, Eng Soon [7 ]
Lim, Jae-Hong [8 ]
Je, Jun-Ho [9 ]
Kohmura, Yoshiki [10 ]
Ishikawa, Tetsuya [10 ]
Margaritondo, Giorgio [11 ,12 ,13 ]
Hwu, Yeukuang [1 ]
机构
[1] Acad Sinica, Inst Phys, 128 Acad Rd Sec 2, Taipei 11529, Taiwan
[2] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
[3] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai, Peoples R China
[4] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Pharmacol, Singapore, Singapore
[5] Natl Univ Hlth Syst, Natl Univ Hosp, Dept Anaesthesia, Singapore, Singapore
[6] Nanyang Polytech, Sch Chem & Life Sci, Singapore, Singapore
[7] Natl Univ Singapore, Dept Phys, eMaGIC Lab, Singapore, Singapore
[8] Pohang Univ Sci & Technol, Pohang Accelerator Lab, Pohang 37673, Gyeongbuk, South Korea
[9] Pohang Univ Sci & Technol, Dept Mat Sci & Engn, Pohang 37673, Gyeongbuk, South Korea
[10] RIKEN SPring 8 Ctr, Sayo, Hyogo 6795148, Japan
[11] Ecole Polytech Fed Lausanne, Fac Sci Base, CH-1015 Lausanne, Switzerland
[12] Natl Tsing Hua Univ, Brain Res Ctr, Hsinchu 30013, Taiwan
[13] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 70100, Taiwan
关键词
microtomography; high-resolution X-ray imaging; brain imaging; SYNCHROTRON-RADIATION; RAY; SHADOW;
D O I
10.1107/S1600577521007633
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The new Brain Imaging Beamline (BIB) of the Taiwan Photon Source (TPS) has been commissioned and opened to users. The BIB and in particular its endstation are designed to take advantage of bright unmonochromatized synchrotron X-rays and target fast 3D imaging, similar to 1 ms exposure time plus very high similar to 0.3 mu m spatial resolution. A critical step in achieving the planned performances was the solution to the X-ray induced damaging problems of the detection system. High-energy photons were identified as their principal cause and were solved by combining tailored filters/attenuators and a high-energy cut-off mirror. This enabled the tomography acquisition throughput to reach >1 mm(3) min(-1), a critical performance for large-animal brain mapping and a vital mission of the beamline.
引用
收藏
页码:1662 / 1668
页数:7
相关论文
共 37 条
[1]   X-ray multilayer monochromator with enhanced performance [J].
André, JM ;
Benbalagh, R ;
Barchewitz, R ;
Ravet, MF ;
Raynal, A ;
Delmotte, F ;
Bridou, F ;
Julié, G ;
Bosseboeuf, A ;
Laval, R ;
Soullie, G ;
Rémond, C ;
Fialin, M .
APPLIED OPTICS, 2002, 41 (01) :239-244
[2]   Characterisation of LSO:Tb scintillator films for high resolution X-ray imaging applications [J].
Cecilia, A. ;
Rack, A. ;
Douissard, P. -A. ;
Martin, T. ;
Rolo, T. dos Santos ;
Vagovic, P. ;
Pelliccia, D. ;
Couchaud, M. ;
Dupre, K. ;
Baumbach, T. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 :S292-S293
[3]   Design of an X-ray 3D Microtomography Beamline for Full field Hard X-ray Projection Imaging at the Taiwan Photon Source [J].
Chang, Shih-Hung ;
Chang, Chao-Yu ;
Liu, Chin-Yen ;
Chang, Chia-Feng ;
Chiang, Liang-Chih ;
Liao, Bo-Yi ;
Chen, Yu-Sheng ;
Chen, Hsiang-Hsin ;
Yang, Shun-Min ;
Lee, Tsung-Tse ;
Chen, Ying-Jie ;
Chen, Fung-Lan ;
Hwu, Yeu-Kuang .
13TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI2018), 2019, 2054
[4]   Imaging cells and sub-cellular structures with ultrahigh resolution full-field X-ray microscopy [J].
Chien, C. C. ;
Tseng, P. Y. ;
Chen, H. H. ;
Hua, T. E. ;
Chen, S. T. ;
Chen, Y. Y. ;
Leng, W. H. ;
Wang, C. H. ;
Hwu, Y. ;
Yin, G. C. ;
Liang, K. S. ;
Chen, F. R. ;
Chu, Y. S. ;
Yeh, H. I. ;
Yang, Y. C. ;
Yang, C. S. ;
Zhang, G. L. ;
Je, J. H. ;
Margaritondo, G. .
BIOTECHNOLOGY ADVANCES, 2013, 31 (03) :375-386
[5]   A synchrotron X-ray imaging strategy to map large animal brains [J].
Chin, An-Lun ;
Yang, Shun-Min ;
Chen, Hsiang-Hsin ;
Li, Min-Tsang ;
Lee, Tsung-Tse ;
Chen, Ying-Jie ;
Lee, Ting-Kuo ;
Petibois, Cyril ;
Cai, Xiaoqing ;
Low, Chian-Ming ;
Tan, Francis Chee Kuan ;
Teo, Alvin ;
Tok, Eng Soon ;
Ong, Edwin B. L. ;
Lin, Yen-Yin ;
Lin, I-Jin ;
Tseng, Yi-Chi ;
Chen, Nan-Yow ;
Shih, Chi-Tin ;
Lim, Jae-Hong ;
Lim, Jun ;
Je, Jung-Ho ;
Kohmura, Yoshiki ;
Ishikawa, Tetsuya ;
Margaritondo, Giorgio ;
Chiang, Ann-Shyn ;
Hwu, Yeukuang .
CHINESE JOURNAL OF PHYSICS, 2020, 65 :24-32
[6]   RADIATION EFFECTS IN GLASSES [J].
EHRT, D ;
VOGEL, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 65 (1-4) :1-8
[7]   Ultrafast X-ray phase-contrast imaging of the initial coalescence phase of two water droplets [J].
Fezzaa, Kamel ;
Wang, Yujie .
PHYSICAL REVIEW LETTERS, 2008, 100 (10)
[8]   One-minute nano-tomography using hard X-ray full-field transmission microscope [J].
Ge, Mingyuan ;
Coburn, David Scott ;
Nazaretski, Evgeny ;
Xu, Weihe ;
Gofron, Kazimierz ;
Xu, Huijuan ;
Yin, Zhijian ;
Lee, Wah-Keat .
APPLIED PHYSICS LETTERS, 2018, 113 (08)
[9]   X-RAY INTERACTIONS - PHOTOABSORPTION, SCATTERING, TRANSMISSION, AND REFLECTION AT E=50-30,000 EV, Z=1-92 [J].
HENKE, BL ;
GULLIKSON, EM ;
DAVIS, JC .
ATOMIC DATA AND NUCLEAR DATA TABLES, 1993, 54 (02) :181-342
[10]   Coherence-enhanced synchrotron radiology: simple theory and practical applications [J].
Hwu, Y ;
Tsai, WL ;
Groso, A ;
Margaritondo, G ;
Je, JH .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2002, 35 (13) :R105-R120