Electrochemical study of the antineoplastic agent etoposide at carbon paste electrode and its determination in spiked human serum by differential pulse voltammetry

被引:24
|
作者
Radi, Abd-Elgawad [1 ]
Abd-Elghany, Nadia
Wahdan, Tarek
机构
[1] Mansoura Univ, Fac Sci Dumyat, Dept Chem, Dumyat 34517, Egypt
[2] Suez Canal Univ, Fac Educ, Dept Chem, Al Arish 45111, Egypt
关键词
etoposide; differential pulse voltammetry; carbon paste electrode; electrochemical oxidation; pharmaceutical analysis;
D O I
10.1248/cpb.55.1379
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
The electrochemical oxidation of the antineoplastic agent etoposide was studied at carbon paste electrode in Britton-Robinson buffer solutions over the pH range 2.0-10.0 using cyclic, linear sweep and differential pulse voltammetry. Oxidation of the drug was effected in a single reversible, diffusion-controlled step within the pH range 2.0-4.0, a second oxidation process was produced above pH 4.0. Using differential pulse voltammetry (DPV), the drug yielded a well-defined voltammetric response in Britton-Robinson buffer, pH 3.0 at 0.500 V (vs. Ag/AgCl) on carbon paste electrode. This process could be used to determine etoposide concentrations in the range 2.5 x 10(-7) to 2.5 x 10(-5) M with a detection limit of 1.0 x 10(-7) M. The method was successfully applied to the determination of the drug in spiked human serum.
引用
收藏
页码:1379 / 1382
页数:4
相关论文
共 50 条
  • [1] Determination of melatonin by differential pulse voltammetry at modified carbon paste electrode
    Bekheit, GE
    ASIAN JOURNAL OF CHEMISTRY, 2000, 12 (02) : 541 - 547
  • [2] Determination of tenoxicam on carbon paste electrode by cyclic and differential pulse voltammetry
    Bruña, JAA
    Sánchez, CD
    Barbado, MDV
    Garcia, MLT
    Batanero, PS
    QUIMICA ANALITICA, 1999, 18 (04): : 329 - 335
  • [3] Differential pulse voltammetry for determination of paracetamol at a pumice mixed carbon paste electrode
    Wang, CY
    Hu, XY
    Leng, ZZ
    Yang, GJ
    Jin, GD
    ANALYTICAL LETTERS, 2001, 34 (15) : 2747 - 2759
  • [4] Differential pulse voltammetry for determination of benorilate in pharmaceutical formulations at carbon paste electrode
    Wang, CY
    Hu, XY
    Chen, Q
    Rong, G
    ANALYTICAL LETTERS, 2005, 38 (05) : 893 - 905
  • [5] DETERMINATION OF HYDROXYZINE BY DIFFERENTIAL PULSE ANODIC VOLTAMMETRY USING CARBON PASTE ELECTRODE
    Zayed, Sayed I. M.
    Al-Talhi, Amal. A. H.
    Al Thagafi, Asmaa E.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2018, 63 (03): : 4064 - 4067
  • [6] Electrochemical study of zolpidem at glassy carbon electrode and its determination in a tablet dosage form by differential pulse voltammetry
    Radi, AE
    Bekhiet, G
    Wahdan, T
    CHEMICAL & PHARMACEUTICAL BULLETIN, 2004, 52 (09) : 1063 - 1065
  • [7] DETERMINATION OF PHENOL BY DIFFERENTIAL PULSE VOLTAMMETRY WITH A SEPIOLITE-MODIFIED CARBON PASTE ELECTRODE
    HERNANDEZ, L
    HERNANDEZ, P
    SOSA, Z
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1988, 331 (05): : 525 - 527
  • [8] Electrochemical study of the antiplatelet agent clopidogrel and its determination using differential pulse voltammetry in bulk form and pharmaceutical preparations with a glassy carbon electrode
    Dermis, S.
    Aydogan, E.
    PHARMAZIE, 2010, 65 (03): : 175 - 181
  • [9] Electrochemical determination of alkaline phosphatase in human serum by differential pulse voltammetry
    Sun, W
    Jiao, K
    Wang, HY
    Lu, LD
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2004, 20 (06) : 690 - 693
  • [10] Electrochemical Determination of Alkaline Phosphatase in Human Serum by Differential Pulse Voltammetry
    SUN Wei 1
    2. College of Chemistry and Molecular Engineering
    Chemical Research in Chinese Universities, 2004, (06) : 690 - 693