Power Quality Improvement Using Zig-Zag Transformer and DSTATCOM in Three Phase Power Distribution System

被引:0
作者
Kulkarni, Onkar Vitthal [1 ]
Mishra, Mahesh K. [1 ]
机构
[1] Indian Inst Technol Madras, Dept Elect Engn, Madras, Tamil Nadu, India
来源
2013 ANNUAL IEEE INDIA CONFERENCE (INDICON) | 2013年
关键词
Zig-Zag transformer; Active power filter; Hysteresis band; Reference filter current; Neutral current compensation;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
This paper proposes a topology consisting of Zig-Zag transformer for neutral current compensation and reduced rating three-leg single capacitor DSTATCOM for load balancing and unity power factor operation in the presence of unbalanced and distorted load voltages. The detailed analysis of different voltages induced and currents flowing inside Zig-Zag transformer shows that Zig-Zag transformer provides low impedance path to zero sequence currents. In addition to that, the potential of the floating neutral of the Zig-Zag transformer connected to a three-phase source measured with respect to the neutral of that three-phase source equals the zero sequence voltage component of that source. This property can be used to get neutral current compensation in three-phase four-wire power distribution system even in presence of unbalanced and distorted voltages. As the neutral current (total zero sequence current) is being taken care by Zig-Zag transformer, a reduced rating DSTATCOM can be used for load balancing and unity power factor operation using instantaneous symmetrical components theory. A detailed simulation study for the proposed scheme is carried out using PSCAD software.
引用
收藏
页数:6
相关论文
共 8 条
  • [1] Comments on active power flow and energy accounts in electrical systems with nonsinusoidal waveforms
    Czarnecki, LS
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1996, 11 (03) : 1244 - 1250
  • [2] George V., IEEE T POWER ELECT
  • [3] PLL-less active power filter based on one-cycle control for compensating unbalanced loads in three-phase four-wire system
    Hirve, Sachine
    Chatterjee, Kishore
    Femandes, B. G.
    Imayavaramban, M.
    Dwari, Suman
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) : 2457 - 2465
  • [4] Analysis of Zig-Zag transformer applying in the three-phase four-wire distribution power system
    Jou, HL
    Wu, JC
    Wu, KD
    Chiang, WJ
    Chen, YH
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1168 - 1173
  • [5] Mishra Mahesh K., 2012, NPTEL COURSE
  • [6] Analysis of the Neutral Current for Two-Step-Type Poles in Distribution Lines
    Park, Keon-Woo
    Seo, Hun-Chu
    Kim, Chu-Hwan
    Jung, Chang-Soo
    Yoo, Yeon-Pyo
    Lim, Yong-Hoon
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (03) : 1483 - 1489
  • [7] Reduced Rating VSC With a Zig-Zag Transformer for Current Compensation in a Three-Phase Four-Wire Distribution System
    Singh, Bhim
    Jayaprakash, P.
    Somayajulu, T. R.
    Kothari, D. P.
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 249 - 259
  • [8] EFFECTS OF HARMONICS ON EQUIPMENT
    WAGNER, VE
    BALDA, JC
    BARNES, TM
    EMANNUEL, AE
    FERRARO, RJ
    GRIFFITH, DC
    HARTMANN, DP
    HORTON, WF
    JEWELL, WT
    MCEACHERN, A
    PHILEGGI, DJ
    REID, WE
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) : 672 - 680