On-Site Determination of Carbendazim, Cathecol and Hydroquinone in Tap Water Using a Homemade Batch Injection Analysis Cell for Screen Printed Electrodes

被引:20
作者
Caramit, Ricardo Pini [1 ]
Lucca, Bruno Gabriel [1 ]
Ferreira, Valdir Souza [1 ]
Abarza Munoz, Rodrigo Alejandro [2 ]
Richter, Eduardo Mathias [2 ]
Bezerra da Silva, Rodrigo Amorim [3 ]
机构
[1] Univ Fed Mato Grosso do Sul, Inst Quim, BR-79074460 Campo Grande, MS, Brazil
[2] Univ Fed Uberlandia, Inst Quim, BR-38408100 Uberlandia, MG, Brazil
[3] Fundacao Univ Fed Grande Dourados, Fac Ciencias Exactas & Tecnol, BR-79804970 Dourados, MS, Brazil
关键词
Batch injection analysis (BIA); Screen-printed electrodes; Homemade portable system; On-site analysis; STRIPPING VOLTAMMETRY; CONTINUOUS-FLOW; NATURAL-WATERS; FIELD ANALYSIS; SYSTEM; CARBON; BIODIESEL; ANALYZER;
D O I
10.1002/elan.201400454
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we present a simple homemade batch-injection analysis cell for screen-printed electrodes (BIA-SPE). The potential of the proposed system for on-site analysis was demonstrated by the determination of carbendazim, catechol, and hydroquinone in tap water. The system provided reduced injection volume (30 mu L), high analytical frequency (approximate to 200 h(-1)) and low detection limits (nanomolar level). Moreover, the BIA-SPE cell presented better stability (RSD approximate to 0.4%) than a conventional flow injection cell for SPE (RSD approximate to 5.0%) in organic media. The proposed homemade BIA-SPE cell is very simple, inexpensive and can be easily constructed in any laboratory.
引用
收藏
页码:271 / 275
页数:5
相关论文
共 27 条
[1]   Lab-on-Chip Measurement of Nitrate and Nitrite for In Situ Analysis of Natural Waters [J].
Beaton, Alexander D. ;
Cardwell, Christopher L. ;
Thomas, Rupert S. ;
Sieben, Vincent J. ;
Legiret, Francois-Eric ;
Waugh, Edward M. ;
Statham, Peter J. ;
Mowlem, Matthew C. ;
Morgan, Hywel .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (17) :9548-9556
[2]   Development of a portable electroanalytical system for the stripping voltammetry of metals: Determination of copper in acetic acid soil extracts [J].
Beni, V ;
Ogurtsov, VI ;
Bakunin, NV ;
Arrigan, DWM ;
Hill, M .
ANALYTICA CHIMICA ACTA, 2005, 552 (1-2) :190-200
[3]   AMPEROMETRIC AND VOLTAMMETRIC DETECTION IN BATCH INJECTION-ANALYSIS [J].
BRETT, CMA ;
BRETT, AMO ;
MITOSERIU, LC .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3145-3150
[4]   AMPEROMETRIC BATCH INJECTION-ANALYSIS - THEORETICAL ASPECTS OF CURRENT TRANSIENTS AND COMPARISON WITH WALL-JET ELECTRODES IN CONTINUOUS-FLOW [J].
BRETT, CMA ;
BRETT, AMO ;
MITOSERIU, LC .
ELECTROANALYSIS, 1995, 7 (03) :225-229
[5]   A new voltammetric method for the simultaneous determination of the antioxidants TBHQ and BHA in biodiesel using multi-walled carbon nanotube screen-printed electrodes [J].
Caramit, Ricardo Pini ;
de Freitas Andrade, Adriana Garabini ;
Gomes de Souza, Joao Batista ;
de Araujo, Tatiane Alfonso ;
Viana, Luiz Henrique ;
Goncalves Trindade, Magno Aparecido ;
Ferreira, Valdir Souza .
FUEL, 2013, 105 :306-313
[6]   Rapid Field Identification of Subjects Involved in Firearm-Related Crimes Based on Electroanalysis Coupled with Advanced Chemometric Data Treatment [J].
Ceto, Xavier ;
O'Mahony, Aoife M. ;
Samek, Izabela A. ;
Windmiller, Joshua R. ;
del Valle, Manel ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2012, 84 (23) :10306-10314
[7]   A disposable screen-printed silver strip sensor for single drop analysis of halide in biological samples [J].
Chiu, Mei-Hsin ;
Cheng, Wan-Ling ;
Muthuraman, Govindan ;
Hsu, Cheng-Teng ;
Chung, Hsieh-Hsun ;
Zen, Jyh-Myng .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (10) :3008-3013
[8]   Rapid and semi-quantitative presumptive tests for opiate drugs [J].
Choodum, Aree ;
Daeid, Niamh Nic .
TALANTA, 2011, 86 :284-292
[9]   Flow injection amperometric determination of isoniazid using a screen-printed carbon electrode modified with silver hexacyanoferrates nanoparticles [J].
de Oliveira, Paulo Roberto ;
Oliveira, Marcela Mohallem ;
Zarbin, Aldo J. G. ;
Marcolino-Junior, Luiz Humberto ;
Bergamini, Marcio F. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 171 :795-802
[10]   A Simple Strategy to Improve the Accuracy of the Injection Step in Batch Injection Analysis Systems with Amperometric Detection [J].
Gimenes, Denise Tofanello ;
Pereira, Polyana Fernandes ;
Cunha, Rafael Rodrigues ;
Bezerra da Silva, Rodrigo Amorim ;
Abarza Munoz, Rodrigo Alejandro ;
Richter, Eduardo Mathias .
ELECTROANALYSIS, 2012, 24 (09) :1805-1810