Transit-time flow measurement is essential in coronary artery bypass grafting

被引:64
作者
Leong, DKH
Ashok, V
Nishkantha, A
Shan, YH
Sim, EKW
机构
[1] Natl Univ Singapore Hosp, Dept Cardiac Thorac & Vasc Surg, Singapore 119074, Singapore
[2] Natl Univ Singapore, Fac Med, Singapore, Singapore
关键词
D O I
10.1016/j.athoracsur.2004.06.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Patent bypass grafts are fundamental to successful coronary artery bypass grafting. Intraoperative flow measurement through newly constructed grafts is a test of patency. We studied the use of transit-time flow measurement to determine its ability to detect technical errors in grafts, to measure the mean flow norms for Asian patients, and to compare arterial and vein grafts. Methods. From January 1, 2001, to June 30, 2002, 116 patients underwent isolated primary coronary artery bypass grafting. Sixty-seven patients underwent conventional coronary artery bypass grafting and 49 patients underwent off-pump coronary artery bypass grafting. There were 125 arterial and 197 vein grafts. Transit-time flow measurement was carried out on all completed grafts. Graft patency was assessed using flow curves, mean flow, and pulsatility index. Average of mean flows was calculated to determine mean flow norms. Arterial and vein grafts were compared by statistical analysis between the variables mean flow and pulsatility index. Results. In 6 patients with seven grafts, intraoperative graft assessment detected technical errors, which were corrected. Average mean flow was 37.4 23.5 mL/min for left anterior descending coronary artery-to-left internal mammary artery grafts, and values ranging from 21.2 to 36.0 mL/min for the rest. There were no statistically significant differences in mean flow or pulsatility index between arterial and vein grafts. Conclusions. Transit-time flow measurement enables technical problems to be diagnosed accurately, allowing prompt revision of grafts. It should be mandatory in coronary artery bypass grafting to improve surgical outcomes.
引用
收藏
页码:854 / 858
页数:5
相关论文
共 24 条
[1]   Minimally invasive coronary artery bypass grafting [J].
Acuff, TE ;
Landreneau, RJ ;
Griffith, BP ;
Mack, MJ .
ANNALS OF THORACIC SURGERY, 1996, 61 (01) :135-137
[2]  
BARNER HB, CIRCULATION S3, V54, P70
[3]   Transit time flow measurement: Experimental validation and comparison of three different systems [J].
Beldi, G ;
Bosshard, A ;
Hess, OM ;
Althaus, U ;
Walpoth, BH .
ANNALS OF THORACIC SURGERY, 2000, 70 (01) :212-217
[4]   EFFECT OF APROTININ (TRASYLOL) ON AORTA-CORONARY BYPASS GRAFT PATENCY [J].
BIDSTRUP, BP ;
UNDERWOOD, SR ;
SAPSFORD, RN .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1993, 105 (01) :147-153
[5]  
Canver CC, 1997, J CARDIOVASC SURG, V38, P211
[6]   Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting [J].
D'Ancona, G ;
Karamanoukian, HL ;
Ricci, M ;
Schmid, S ;
Bergsland, J ;
Salerno, TA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) :287-293
[7]  
DANCONA C, 2000, HEART SURG
[8]   Minimally invasive coronary artery bypass grafting without cardiopulmonary bypass: Early experience and follow-up [J].
Diegeler, A ;
Falk, V ;
Matin, M ;
Battellini, R ;
Walther, T ;
Autschbach, R ;
Mohr, FW .
ANNALS OF THORACIC SURGERY, 1998, 66 (03) :1022-1025
[9]   EARLY AND LATE RESULTS OF CORONARY REVASCULARIZATION WITH SAPHENOUS-VEIN AND INTERNAL MAMMARY ARTERY GRAFTS [J].
GEHA, AS ;
BAUE, AE .
AMERICAN JOURNAL OF SURGERY, 1979, 137 (04) :456-463
[10]   STARTING ASPIRIN THERAPY AFTER OPERATION - EFFECTS ON EARLY GRAFT PATENCY [J].
GOLDMAN, S ;
COPELAND, J ;
MORITZ, T ;
HENDERSON, W ;
ZADINA, K ;
OVITT, T ;
KERN, KB ;
SETHI, G ;
SHARMA, GVRK ;
KHURI, S ;
RICHARDS, K ;
GROVER, F ;
MORRISON, D ;
WHITMAN, G ;
CHESLER, E ;
SAKO, Y ;
PACOLD, I ;
MONTOYA, A ;
DEMOTS, H ;
FLOTEN, S ;
DOHERTY, J ;
READ, R ;
SCOTT, S ;
SPOONER, T ;
MASUD, Z ;
HAAKENSON, C ;
HARKER, LA .
CIRCULATION, 1991, 84 (02) :520-526